Certified physical security

ArxBridge
Sandstone Victorian building with a navy security door in Glasgow

Security · LPS 1175 SR2 to SR5

Security Doors in Glasgow

Security doors for Glasgow offices, retail and industrial estates: ratings, fire and security on one doorset, wet-weather finishes, and the order.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Glasgow
Prefer to talk?+44 7352 267239

Get a free quote in Glasgow

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Glasgow

What we supply in Glasgow

More on this

A Glasgow buyer gets the right result by starting with the opening and the building around it. A steel door rated B3 or C5 fits most entrances, a fire rated doorset belongs on every escape route, and a gate beside a yard needs a rating of its own.

Glasgow is Scotland’s largest city, and its buildings ask different questions of their doors. Offices and shops fill the city centre, industrial estates and distribution units sit on out-of-town sites, and each kind of building needs a door that suits its own use.

The way to keep the order straight is one list with one row per opening. Each row carries the building, the position, the fire period, the security rating where one is needed, and the leaf, the frame, the glass, the seals and the hardware as a single doorset. Our Glasgow page covers the city as a whole, and our Edinburgh page covers the capital to the east.

  • LPS 1175Forced entry rating, B3 to D10
  • ISO 22343-1Vehicle impact test for gates and yards
  • FD30 / FD60Fire resistance periods tested to EN 1634-1
  • BS EN 1935Hinge grades 13 and 14 for heavy leaves

Offices and shops in the city centre: entrances the public uses

A city centre office in Glasgow meets the public every day. Staff arrive in the morning, visitors arrive through the day, and deliveries come to the side door, so the entrance has to admit the right people and keep strangers out. A glazed entrance lets reception see who stands at the door before it is opened, and a rated screen holds while the door is checked. Our fire rated windows guide sets out how glass, frame and beads are tested together.

Shop doors work to a different rhythm. A shopfront has to take a crowd at opening time, and the same doors have to let that crowd out in one action when the alarm sounds. Panic hardware to BS EN 1125 belongs on these doors, with a bar across the leaf covering at least 60 percent of the leaf width, on doors that serve more than 60 people. A door has to open with less than 30 N in the first 30 degrees and less than 22.5 N beyond that, under BS 8300 and Approved Document M. A closer that is too strong for the leaf makes the door fail the access rules. Our fire door closers guide sets out the power sizes in BS EN 1154.

Premises that hold crowds face duties under Martyn’s Law, which sets tiers for premises that hold 200 or more people, with Royal Assent in April 2025 and go-live expected in spring 2027. The doors that release a crowd sit inside those duties, so they have to open in one action, in the direction of escape, without a key. Our Martyn’s Law guide sets out the tiers and what they ask of a premises.

Industrial estates and distribution units: doors that work every day

A personnel door on a distribution unit opens and closes more often than any other door in Glasgow. It opens for every shift change, every delivery and every break, and a door built for a quiet office will not last on a unit floor.

A steel leaf takes the daily knocks these doors meet: forklifts, pallets, trolleys and boots all meet the same leaf, day after day. A steel leaf is strong, but strength on its own is not a security rating, and a door that stands up to a knock can still fail a forced entry test. The rating belongs to the whole tested assembly, leaf, frame, fixings, glazing and hardware tested together, so a rated leaf in an untested frame is not a rated door. Our warehouse security doors guide covers the doors distribution buildings need most.

A loading bay needs a door of its own, and the personnel door beside the bay lets staff in and out without opening the bay. Our loading bay doors guide covers the bay doors in full.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Reading B3, C5 and D10 before a Glasgow order is placed

LPS 1175 tests a doorset against tools and time. B3, once called SR2, holds for three minutes against screwdrivers, pliers and hand saws. C5, once called SR3, holds for five minutes against crowbars, drills and chisels. D10, once called SR4, holds for ten minutes against sledgehammers, disc cutters and jigsaws. Read the letter and the number together, because neither half means much on its own.

Let the risk of each opening set the rating, not the area it sits in. A shopfront on a busy street needs a higher rating than a store door in a quiet yard. Our keeping an LPS 1175 rating valid guide sets out the changes that void a rating, and our LPS 1175 vs PAS 24 guide compares the two routes side by side.

PAS 24 is the enhanced security standard for doorsets, while EN 1627 gives resistance classes RC1 to RC6 for windows, doors and shutters. Secured by Design is a scheme, not a rating, so a door with the scheme mark but no test rating has no proven resistance behind it. Our SR2 vs SR3 vs SR4 guide works through the three ratings buyers meet most often.

One doorset, two duties: fire and forced entry together

Many doors in Glasgow have to do two jobs at once: hold fire and resist a forced entry. A server room door has to hold fire and resist an attack on the equipment inside. Both jobs need their own evidence on the same assembly: a fire classification to EN 1634-1 and a forced entry rating to LPS 1175 or PAS 24. Our dual certification guide works through how fire and security sit on one assembly.

FD30 and FD60 name fire resistance periods from the EN 1634-1 test, and the number is the minutes the doorset keeps its rating in the furnace. FD30S adds smoke control to 30 minutes of integrity, tested to BS EN 1634-3. EI caps the temperature rise on the safe side, 140 degrees Celsius on average and 180 degrees at most. Change the leaf, the frame, the glass, the seals or the hardware and the tested construction can break, leaving the door with no proven rating.

One access system for several Glasgow sites

Sites across Glasgow should share one access system instead of running one per site. Staff carry cards, visitors use a code or a pass, and contractors get a temporary credential that stops working when the job ends. The method fits the entrance: readers that keep up with walking pace suit a city centre office, and cards that work at shift change suit a distribution unit.

Settle what each door does when the power fails, and prove it by switching the power off. A door that must stay locked for security and a door that must open for escape need opposite answers, and the facilities team needs the answer in writing where it can be found. Tie the doors into the same system as the turnstiles, the lifts and the car park, so access lost in one place is lost everywhere at once. Our security turnstiles guide works through readers, fobs and biometrics and how the lane is wired into the access system.

The Clyde waterfront and the exhibition quarter: doors for crowds

The Scottish Event Campus stands on the north bank of the River Clyde at Finnieston, west of the city centre. Three venues share the site: the SEC Centre, the SEC Armadillo and the OVO Hydro. The Armadillo seats 3,000 and opened in 1997. The OVO Hydro opened in September 2013 and holds up to 14,300 people. A campus of that size puts crowds through its doors in waves, at the start of a show, at the interval and at the end of the night.

A crowd door has to release a whole audience at once, with no key and no second move, and the same door has to hold a crowd out when the building is closed. Where a door serves a room of more than 60 people, it needs panic hardware to BS EN 1125, with a push bar across most of the leaf, at least 60 percent of its width. A venue that holds 14,300 people sits far above the 200 person threshold in Martyn’s Law, so the release of a crowd sits inside the duties the premises carries. The exhibition centre security doors guide gives venue doors in full, and the Martyn’s Law guide gives the tiers in full.

An exhibition hall adds a second problem. A hall door has to admit forklifts and crates during build up and hold a crowd during the show. A wide leaf needs hinges to BS EN 1935, grade 13 for a leaf of 120 kg or grade 14 for a leaf of 160 kg, each tested to 200,000 cycles. BS 8300 and Approved Document M cap the opening force at 30 N through the first 30 degrees, and at 22.5 N after that, so the closer must be sized to the leaf, not to the catalogue. Rain and wind from the Clyde reach the riverside doors first, so the finish on those leaves needs the same attention as the finish on an industrial door.

Universities and the hospital estate: doors that serve the public all day

Glasgow has three universities in the city itself. The University of Glasgow keeps its main Gilmorehill campus in the West End. The University of Strathclyde sits in the city centre. Glasgow Caledonian University sits at Cowcaddens, just north of the city centre. A campus door sees students, staff and visitors from early morning to late evening, and a lecture theatre door has to empty a full room at once if the alarm sounds. The university security doors guide gives campus doors in full.

The Queen Elizabeth University Hospital stands at Govan in the south west of the city and opened in April 2015. It is a 1,677 bed acute hospital, with a 1,109 bed adult hospital and a 256 bed children’s hospital, and two emergency departments, one for adults and one for children. A hospital door carries three duties in one leaf. It must hold fire for its rated period. It must resist forced entry where the room needs it. And it must open with a force a patient or a visitor can manage. A ward door needs a fire rating to EN 1634 part 1, and a door on a store for drugs or equipment needs a forced entry rating to LPS 1175 as well, with the evidence naming the whole doorset. The hospital security doors guide gives hospital doors in full, and the fire door regulations for hospitals guide gives the fire periods in full.

Building Door Rating to name What to check
OVO Hydro Arena exit doors Panic hardware to BS EN 1125 One action release, direction of escape
SEC Centre Hall doors LPS 1175 B3 or C5 where rated Hinges, closer force, leaf width
University campus Lecture theatre doors FD30 or FD60 Gaps, seals, self closing
Queen Elizabeth University Hospital Ward and store doors FD60 and LPS 1175 where rated Fire and security evidence on one doorset

Wet weather and cold winters: finishes that hold up in Glasgow

How long a Glasgow door lasts comes down to its finish, and the finish comes down to the weather it faces. Powder coating adds colour and a hard skin, and it fits doors kept out of the weather. Galvanising coats the steel in zinc, edges and cut sections included, and it fits doors that stand in rain and cold. A galvanised base under a powder coated top coat gives both kinds of protection. Ask which finish the tested doorset allows. Our powder coating page covers the finish options.

Give the hinges and fixings the same care as the leaf. Hinges to BS EN 1935, grade 13 or grade 14, carry the leaf, and a hinge that drops lets the leaf sag until the closer cannot shut it square. A hold-open device to BS EN 1155 holds a door open for use and lets it go when the alarm sounds, so test the release at every inspection. Look at the gaps and seals on the same visit: 4 mm around the leaf is the usual limit, and intumescent seals close the gap in a fire as they expand at roughly 200 to 250 degrees.

Before ordering: planning, conservation areas and listed buildings

A like-for-like replacement inside an existing opening usually needs no planning permission, but three cases call for a check with Glasgow City Council before ordering. Major changes to the outside of a building can need permission. Work in a conservation area faces extra controls. And a listed building needs separate consent, which is the case buyers miss most often.

A listed building brings duties a new building never has, and a door fitted without consent can be ordered out again. Ask the planning authority what the job needs, and put the listing and the conservation area beside the door schedule in the enquiry.

George Square and the Gilbert Scott Building: doors that fit an old opening

Glasgow City Chambers stands on the east side of George Square. Queen Victoria inaugurated the building in August 1888, it is listed Category A, and it still houses Glasgow City Council. A door here cannot be treated as a new build opening. The leaf has to fit the stone opening it already has, and any change to the outside needs listed building consent from the council before work starts.

The Gilbert Scott Building at Gilmorehill is the same kind of problem in a different setting. The main building opened in November 1870, its tower and spire were finished in 1891, and the whole building is listed Category A. Inside, the doors serve halls and teaching rooms that fill and empty through the day, so a fire door there needs its rating to EN 1634-1, and the gap around the leaf needs to stay at 4 mm, because a wide gap lets smoke through early. The closer on a heavy old leaf needs a power size from BS EN 1154, with EN 3 the minimum on a fire door, and the smallest size that shuts the leaf is the right one.

A listed opening also changes what the hardware can be. A cylinder that meets TS 007 reaches the 3-star rating with a 1-star cylinder and a 2-star handle, or the other way round, so name both parts on the schedule rather than the cylinder alone. A sash window beside the door needs the same thought: a security sash window keeps the look of the opening and still carries a rating of its own. The listed building fire doors guide gives the consent and fire route in full, and the security sash windows page gives the glazed route beside it.

Buchanan Street, St Enoch and Central station: doors for a shopping and travel crowd

Glasgow Central opened on 1 August 1879 with eight platforms, and it is now the busiest railway station in Scotland and a Category A listed building. Its doors take a flow of travellers all day, so the entrance needs leaves that open with little force and shut on their own, and readers that work at walking pace. Count the peak flow, not a quiet hour, to find the station’s tier: the enhanced tier of Martyn’s Law covers premises where 800 or more people may be present, the Act received Royal Assent in April 2025, and it is expected to come into force in spring 2027. The transport hub security requirements guide gives station doors in full.

A few streets away, the St Enoch Centre opened on 25 May 1989 on the site of the old St Enoch station, at the meeting of Argyle Street and Buchanan Street. A shopping centre door has two jobs that pull in opposite directions: it must let a crowd out in one action when the alarm sounds, and hold that crowd out after closing. Where a door serves a room of more than 60 people, panic hardware to BS EN 1125 belongs on it, with a push bar across at least 60 percent of the leaf. The centre doors and the shopfront doors each have their own brief: the shopping centre security doors guide covers the centre, and the retail security doors guide covers the shopfront.

Building Opening Rating to name What to check
City Chambers Main entrance doors Listed building consent first Fit to the stone opening
Gilbert Scott Building Hall and teaching room doors Fire to EN 1634-1 4 mm gaps, closer power size
Glasgow Central Station entrance doors Panic hardware to BS EN 1125 One action release, reader pace
St Enoch Centre Centre entrance and shopfront doors LPS 1175 where rated Closing hold, escape release

Put the listed buildings on a separate line of the schedule from the crowd buildings. A listed opening needs the consent, the opening size and the finish agreed before the rating is chosen, while a crowd opening needs the release and the tier named first. The two lists meet in one schedule, with one row per opening and the evidence for each.

The enquiry for a Glasgow site: what to put in writing

Ordering doors for a Glasgow site is a specification job, not a shopping trip. The enquiry has to name the building, the position, the fire rating, the security rating where one is needed, and the leaf, the frame, the glass, the beads, the seals and the hardware as one doorset. Where the door must also resist attack, the security side needs its own evidence: a rating to LPS 1175 or PAS 24 that covers the whole doorset, not the leaf alone. Our how to specify security doors guide covers the same discipline column by column.

Ask for the test report, the classification and the hardware schedule to arrive with the doorset, and make sure the handover pack names the inspection routine the site will follow. A site that files its evidence on the day the doors arrive has a record it can use for the whole life of the estate. Put the schedule together first, then order against it. Our fire door inspection checklist gives the checks that catch a failing leaf before it matters.

Premises Door position Rating What to check
City centre office Glazed entrance LPS 1175 where rated Screen rating, reader pace
Industrial unit Personnel door LPS 1175 B3 or C5 Leaf, hinges, latch
Distribution unit Loading bay personnel door LPS 1175 where rated Closer, latch, hold-open release
Stores and plant room Internal doors FD60 Seals, gaps, self-closing

In Glasgow, the entrance that serves a city centre office and the personnel door on a distribution unit answer different questions, and a schedule that gives them the same answer will fail one of them.

What LPS 1175 rating suits a Glasgow industrial unit door?

For most industrial unit doors, B3 fits a staffed front entrance and C5 fits a rear or side door that faces a quiet approach. The risk assessment for that opening should decide.

Can a Glasgow doorset hold a fire rating and a security rating at once?

Yes, where one doorset carries both sets of proof. The fire classification comes from EN 1634-1 and the forced entry rating from LPS 1175 or PAS 24, and the evidence has to name the doorset that will be fitted.

Do I need planning permission to change a door in Glasgow?

A like-for-like replacement inside an existing opening usually needs none. A new opening, work in a conservation area, or work on a listed building calls for a check with Glasgow City Council before ordering.

What finish lasts on a Glasgow industrial door?

Galvanising fits a door that stands in rain and cold, because the zinc coating guards the steel itself, edges and cut sections included. Ask whether the tested doorset allows the finish before ordering.

How do I order doors for several Glasgow sites?

Put together one schedule with one row per opening, naming the building, the position, the fire rating, the security rating and the whole doorset. Ask for the evidence to arrive with the doors, and file it on the day they arrive.

Specifying doors for a Glasgow site?Send the door schedule and the fire strategy for a tested doorset quotation.
Get a free quote

Ready to specify your project?