Fire · EI 30 to EI 120

SR2 Fire Doors in Wolverhampton

SR2 fire doors for Wolverhampton warehouses, factories, schools and hospitals: forced entry and fire resistance in one tested steel doorset, made to size.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Wolverhampton
Prefer to talk?+44 7352 267239

Get a free quote in Wolverhampton

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Wolverhampton

What we supply in Wolverhampton

More on this

A Wolverhampton building that needs a door to hold back both fire and a forced entry attempt has one honest answer: a single doorset tested for both jobs. SR2 fire doors carry a forced entry rating and a fire rating on the same leaf, frame and hardware set, so the door that slows an intruder is the same door that holds a fire in its compartment. That matters where a door sits on a fire escape route and also guards stock, plant or records, because two separate doors cannot share one opening.

Wolverhampton gives that combination plenty of work to do. The i54 park off the M54 at Junction 2 runs advanced manufacturing and distribution units, and the older estates at Pendeford, Bilston and Wednesfield run factories, workshops and warehouses that work through the night. The city centre holds shops, offices and student housing, the University of Wolverhampton holds teaching blocks and halls, New Cross Hospital holds wards and plant rooms, and Molineux holds a stadium that fills and empties on match days. Each of those buildings has doors that must do two things at once, and each one fails its duty if either rating is missing.

SR2 is the forced entry rating in this doorset. LPS 1175 Issue 8.2 (September 2024) ranks doorsets from SR1 to SR5 by the tool set named in the standard and the attack time allowed. The fire rating comes from BS EN 1634-1, which grades a doorset E, EW or EI for 30 to 120 minutes. A dual rated doorset should come with test evidence for both ratings on the same build, not a fire test for one leaf and a security test for another. That evidence is what the buyer checks at handover, and it is what keeps the rating valid when the door is inspected later.

RatingSR2 to LPS 1175 Issue 8.2
Fire ratingE, EW or EI 30 to 120 minutes
LeafSteel doorset made to surveyed sizes
Reply timeOne working day

Where a dual rated doorset earns its place in Wolverhampton

The table below sets out the Wolverhampton buildings where one doorset carrying both ratings is the right call, and the fire rating to ask for in each case. The rating follows the risk at that door and the fire strategy for that part of the building, so the numbers are a starting point for the survey, not a fixed order.

Building in Wolverhampton Why SR2 fits the door Fire rating to ask for
Warehouse or distribution unit Stock and plant behind a door that also sits on a compartment line EI 60
Factory or workshop Tools and materials behind a door used by shift staff at all hours EI 30 or EI 60
School or college block Classrooms and stores behind a door on a corridor escape route EI 30
Hospital ward or plant room Patients and equipment behind a door that must stay shut in a fire EI 60
City centre shop or retail unit Stockroom door that also guards the rear escape route EI 30
Student accommodation block Flat entrance doors on corridors where residents sleep EI 30

What SR2 and the fire rating each prove

The SR2 rating proves the doorset resisted a defined attack for a defined time, using the tool set named in LPS 1175 Issue 8.2. That test covers the leaf, the frame, the hinges, the lock and the fixing into the wall, so a strong leaf on a weak frame earns nothing. The guide to SR2, SR3 and SR4 shows how the classes differ, and when a higher class is worth the extra cost. For most Wolverhampton warehouses, schools and shops, SR2 is the class that matches the risk, while a cash room or a control room may need SR3, which is why the SR3 fire doors range exists alongside it.

The fire rating proves the doorset held its line in a furnace test under BS EN 1634-1. E means integrity, so flame and hot gas do not pass. EW caps radiated heat, and EI caps the temperature of the unexposed face. The fire ratings page explains each letter and each minute band, and the guide to dual certification explains why both ratings must be tested on the same doorset build. A buyer who accepts a fire certificate for one leaf and a security certificate for another has no proof that the door fitted to their opening carries either rating.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Points to settle before the order

Four points decide whether the fitted door keeps its ratings. First, the size: every opening is surveyed, because a doorset made to the surveyed size fits its frame without packing that breaks the seal. Second, the hardware: closers, locks, hinges and seals should come with evidence for the same fire rating and the same SR class as the leaf, since a closer that fails in heat leaves the door open in a fire. Third, the wall: the frame fixing must suit the wall build up, whether brick, block or stud, and the gap between frame and wall must be sealed with the material named in the test evidence. Fourth, the use: a door that staff prop open for deliveries needs a hold open device linked to the fire alarm, or it will stand open when it is needed shut.

Steel is the usual leaf for this doorset, and fire rated steel doors give the strength and the fire performance in one leaf, with a finish that suits a factory floor or a clean corridor. The fire door certification guide sets out the papers to ask for, and the guide to specifying security doors shows how to put rating, size, finish and hardware for each door into a single specification that two suppliers can price on the same basis. Other doors on that Wolverhampton site may need a security rating only, with no fire rating, and the security doors in Wolverhampton page covers those.

A door that carries two ratings on two different test reports is not a dual rated door. Ask for both ratings on one doorset build, in writing, before the order is placed.

From survey to handover in Wolverhampton

Work starts with a survey visit. The surveyor measures each opening, records how the wall is built and what hardware is already fitted, and speaks with the staff who use the doors each day, because a door on a busy warehouse aisle takes different hardware than a door that serves a store. The visit is followed by a written specification, settled with the buyer ahead of any order, naming the SR class and fire rating for each door, with the size, finish and hardware listed beside them. The doorsets are then made to the surveyed sizes and delivered.

Care after handover keeps the ratings alive. The fire door maintenance guide lists what to check on gaps, seals, closers and hinges, and a door checked at set intervals keeps its rating, while a door left unchecked drifts out of rating before anyone notices. Send the opening sizes and the ratings each door needs to [email protected]. A reply arrives within one working day, with a written specification and a date set for the survey visit.

Frequently asked questions

Can one doorset really carry both an SR2 rating and a fire rating?

Yes, when the same doorset build has been tested for both. The fire test and the forced entry test must both cover the leaf, frame and hardware as one build, and the evidence should name both ratings. A leaf tested for fire and a different leaf tested for security do not add up to a dual rated door.

Which fire rating should a Wolverhampton warehouse door carry?

It follows the fire strategy for that part of the building. EI 60 is a common ask for a warehouse compartment door, while EI 30 suits a door on a corridor escape route. The fire risk assessment for the building names the rating, and the specification should copy that rating exactly rather than guessing it.

Do SR2 fire doors suit a school or a hospital in Wolverhampton?

They suit doors where security and fire duties meet, such as a school store on a corridor route or a hospital plant room. A classroom door used by pupils all day needs hardware that staff and pupils can use without a key, so the hardware choice matters as much as the rating. The survey should look at who uses each door before the hardware is named.

What records should I keep after SR2 fire doors are fitted?

Keep the test evidence for both ratings, the hardware schedule, the survey sizes and the handover pack. The fire door regulations for care homes guide shows the kind of record keeping that applies to sleeping accommodation, and the same habit serves any building where fire doors are inspected. Those papers are what an inspector asks to see first.

Need SR2 fire doors for a Wolverhampton building?

Send the sizes of each opening and the rating each door needs. Expect a reply within one working day, with the next step named and the survey visit date. Contact ArxBridge to start.

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.