Fire · EI 30 to EI 120
SR2 fire doors in Solihull
SR2 fire doors in Solihull for shops, hospitals, venues and factories. One doorset carrying a fire class and an SR2 rating, surveyed and fitted.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Solihull
Get a free quote in Solihull
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Solihull
What we supply in Solihull
A buyer in Solihull who wants a fire door with forced entry resistance is buying a single doorset for two duties. Leaf, frame, hinges, lock and closer go through testing as a single assembly, which means the fire rating and the SR2 rating rise and fall together, and the paperwork for the opening lists both. Heat and smoke are held back for the rated period, the B3 tool set is held back for three minutes, and swapping any part after testing voids the pair.
Solihull gives that doorset plenty of work. Touchwood and Mell Square put shopfronts and service corridors beside public walkways, Solihull Hospital runs wards and plant rooms through long days, and the National Exhibition Centre with Resorts World Arena beside it fills halls with crowds on event nights. Birmingham Airport sits close by at Elmdon, the Jaguar Land Rover plant at Solihull runs production buildings with stores and offices, and Birmingham Business Park holds offices and light industrial units across its plots. Shirley, Knowle, Dorridge, Balsall Common and Chelmsley Wood add schools, clinics and small commercial buildings, and the wider West Midlands picture sits on the physical security in Birmingham page.
Where Solihull puts an SR2 fire door to work
The town centre sets the sharpest brief. At Touchwood or in Mell Square, a service door stands between a stock room and a walkway full of shoppers, so the leaf needs to close tight on each swing, the seals need to hold smoke back, and the closer needs sizing to the leaf weight. A cash office door in the same centre takes the same fire class, paired with a lock that staff can undo fast from the inside. The shopping centre fire door guide covers leaves beside public routes, and the retail fire door guide covers shopfronts, stock rooms and rear doors.
Hospitals, halls and the airport set the same brief in other shapes. At Solihull Hospital, ward doors and plant room doors work all day beside trolleys, beds and staff moving between rooms. Halls at the National Exhibition Centre and Resorts World Arena put doors beside crowds on event nights, and Birmingham Airport at Elmdon puts doors beside ticket and information points. The hospital fire door guide covers wards and plant rooms, the exhibition centre fire door guide covers halls and crowd routes, and the transport hub guide covers doors beside passenger routes.
The rest sits with factories, offices and the villages round the town. At the Jaguar Land Rover plant in Solihull, production buildings put stores and offices beside workshops, while Birmingham Business Park puts offices and light industrial units on plots a short walk apart. Shirley, Knowle, Dorridge, Balsall Common and Chelmsley Wood bring schools, clinics and small commercial buildings, each with corridors, stores and plant rooms of its own. The SR2 fire doors parent page lists the product range these Solihull doors come from.
What SR2 means beside a fire class
Risk at the opening fixes the rating, not the size of the leaf. The specification contains LPS 1175 Issue 8.2 (September 2024) approving the SR2 rating for the doors on the schedule, with the fire class for each door written on the same line. The four SR classes are listed below, each with its tool set and its attack time.
| Class | Tool set | Time under attack |
|---|---|---|
| SR2 | B3 | three minutes |
| SR1 | A1 | one minute |
| SR3 | C5 | five minutes |
| SR4 | D10 | ten minutes |
The specification agrees BS EN 1634-1:2014+A1:2018 setting the fire classes E, EW and EI at 30 minute steps to 120 minutes. Which band fits a door is fixed by the fire strategy for where that door stands. The fire ratings page carries the classes behind the test. The 10 steps guide orders the specification work, opening with the risk at the door and closing with the hardware on the leaf.
Two further standards turn up beside the SR2 rating on some orders here. The full SR scale is on the LPS 1175 page, and the dual certification guide explains a leaf that carries a fire class and a security rating at the same time. A door rated under the LPS 2081 route cites LPS 2081 Issue 1.1 (2016), and glazing that must also hold against forced entry is rated under LPS 1270 Issue 1.1 (2014).
Access, hardware and the frame
The leaf is only as strong as the frame round it. Steel is matched to the leaf, hinges are sized to the leaf weight so the leaf never drops, and fixings anchor the frame into the wall so that a blow is met by frame as well as leaf. Intumescent seals and a closer chosen to suit the leaf weight belong in the same line of the specification, and the how to specify guide sets out the checks to make before the order goes in.
A door that resists attack still has to open for everyone who uses it. Under BS 8300 and Approved Document M, the force needed is set at 30 newtons while the leaf swings through its first 30 degrees, then 22.5 newtons after that, and the closer is tuned to the leaf weight and the flow of people through the opening. The access guide carries the opening force limits in full. For life after fitting, read the keeping dual certified doors valid guide, which explains how the rating is kept good once the door is in use.
From survey to fitting in Solihull
Work in Solihull starts at the opening, not at the desk. The surveyor takes breadth and drop at three points and looks at how the wall is built round the opening, and the lintel, the sill and any services that cross the reveal are recorded. The reply arrives in writing inside one working day, and it carries a rating and a price for each opening. The lead times guide lays out each step from survey to fitting.
Survey notes steer the workshop. Site measurements steer the fitting crew, and the frame is set level and square before the leaf is hung. Hinges carry the leaf weight and seals sit round the leaf edge, while the closer is tuned so the leaf shuts tight without a slam. The Romford studio: Saffron Road, Romford, Essex RM5 3ES. The routine checks for each rated opening after handover are set out in the security door maintenance checklist, and the fire rated steel doors page shows the wider range.
Write to [email protected] with details of the rooms each door guards, the fire class for every door and the size of each opening, and the written reply inside one working day names the rating, the fitting route and the price for each opening, with a survey date beside each stage.
A note before you order
A leaf propped open, or a closer too weak for the leaf it serves, leaves the corridor unguarded when it matters. The written specification should name leaf, frame, seals and closer on one line, since the four work as a set and the rating rests on all of them.
Questions about SR2 fire doors in Solihull
What does the SR2 rating add to a fire door in Solihull?
SR2 names a forced entry class under LPS 1175, tested with the B3 tool set over three minutes, and it sits beside the fire class instead of replacing it. A leaf that holds both ratings has been tested for attack and for fire, and the specification for the job should name both ratings on the line for each door, so the leaf that arrives is the leaf that was ordered.
Which fire class fits a shop service door at Touchwood?
The fire strategy for the centre settles it. The class is one of E, EW or EI, in a band of 30, 60, 90 or 120 minutes, and the survey confirms the class for the opening with the wall build and the rooms on each side of the leaf.
Can an SR2 fire door at Solihull Hospital still open easily for staff and patients?
Yes, when the closer matches the leaf weight. The standard holds the push to 30 newtons while the leaf swings through its first 30 degrees, then 22.5 newtons after that, and a leaf that slams or drags wants checking before the seals and hinges wear.
What happens on an SR2 order for the National Exhibition Centre?
Drawings and the fire class for each door come first, then the surveyor measures each opening on site by hand. Each leaf follows the written specification, the leaf is hung and the closer tuned, and the handover sheet names the fire class, the SR2 rating and the hardware for every opening.
Planning SR2 fire doors for a Solihull building? Write with the size of each opening and the fire class for every door, and the written reply will name a tested doorset for each one.
Other areas
SR2 fire doors in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.