Harbourside converted buildings with steel entrance doors in Bristol

Fire · EI 30 to EI 120

SR2 fire doors in Bristol

SR2 fire doors in Bristol with a B3 forced entry class and fire ratings to 120 minutes, surveyed and fitted for hospitals, offices and schools.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Bristol
Prefer to talk?+44 7352 267239

Get a free quote in Bristol

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Bristol

What we supply in Bristol

More on this

A hospital corridor door in Bristol, a stair door in a Harbourside office and a stockroom door in Broadmead all ask for the same thing from one leaf: time against fire and time against a forced entry attempt. SR2 fire doors give both, with a fire rating and a forced entry class tested on the same doorset, so the leaf that holds back smoke and flame also holds back a tool attack for three minutes. That pairing suits a building where a fire door already sits on a compartment line and the entrance also needs a named level of resistance, because one order covers two risks.

Bristol mixes building types that push a fire door in different directions. Bristol Royal Infirmary and Southmead Hospital run corridors where beds, trolleys and porters pass all day, and a door there must close on its own after every passage. Lecture buildings at Bristol’s two universities move hundreds of people between classes, and a door there must open with a light push while still shutting tight. Cabot Circus and Broadmead hold retail units with stockrooms behind the shopfront, Bristol Temple Meads runs a station concourse, and the Harbourside holds offices and restaurants beside the water. Each place needs the same two answers, fire time and forced entry time, in a different balance.

A survey of the opening comes before any catalogue choice. The survey records the size, the wall build up, the traffic through the door and the hardware the users need, and the specification names the fire rating, the forced entry class and the finish for that opening. A door ordered that way arrives made to the surveyed size. The other products fitted in the same buildings appear on the physical security in Bristol page, which covers the city as a whole.

RatingSR2, class B3, 3 minute delay
FireE, EW and EI ratings, 30 to 120 minutes
Gaps4 mm around the leaf
Reply timeOne working day

Where Bristol buildings put an SR2 fire door to work

Hospital corridors give the clearest case for the pairing. On a ward corridor in Bristol Royal Infirmary or Southmead Hospital, a door stands on a compartment line, so it must hold fire and smoke while staff move patients, and it also guards drugs stores and plant spaces where a forced entry attempt is a real risk. The same leaf carries both duties, which keeps the closer, the seals and the lock working as one set. The rules for those rooms are set out in our hospital rules guide, and the routine that keeps the seals and the closer in order is in our maintenance guide.

Offices on the Harbourside and shops in Cabot Circus and Broadmead use the door in a different way. A stair door in an office must stay shut against fire while staff pass through it all day, and a stockroom door must resist a quick attack from the service corridor while the shop stays open. Bristol Temple Meads and Bristol Airport put the same leaf on plant rooms and service doors where the public never goes, and the units at Avonmouth and Filton put it on stores and control rooms beside busy yards. The commercial rules guide covers offices and shops, and the airport rules guide covers terminals.

Fire rating and forced entry class in one leaf

Fire performance is timed in minutes: E for integrity, EW for integrity with limited radiation and EI for integrity with insulation, in steps from 30 to 120 minutes. The test record identifies BS EN 1634-1:2014+A1:2018 therefore, and the rating applies to the leaf, the frame and the seals together, not to the leaf alone. At about 200 to 250 degrees the intumescent seals expand to close the gap round the leaf, and that gap stays at 4 mm, as the gap sizes guide explains. A smoke seal to Sa or S200 keeps cold smoke from passing the closed door, and the fire ratings page lists each one. Each side of a dual certification doorset is checked at handover.

The forced entry side of the leaf is a class, and the class for this door is SR2, which is class B3 under the current issue, with a delay of three minutes against the tool set for that class. The doorset schedule supplies LPS 1175 Issue 8.2 (September 2024) elsewhere in the pack, beside the fire rating, so one document names both tests and the buyer checks one pair of figures at handover. SR1 sits below SR2 and SR3 and SR4 sit above it, so the class follows the risk at that opening. Our LPS 1175 page lists each class with its delay, and our ten steps guide walks through the choices.

Hardware decides whether the two ratings work in daily use. A closer sized from EN 1 to EN 7 under BS EN 1154 must be at least EN 3 on a fire door, so the leaf shuts on its own after every passage. Hinges to BS EN 1935 grade 13 take 120 kg across 200,000 cycles, and grade 14 takes 160 kg across the same cycles, which matters on a heavy steel leaf. A panic bar to BS EN 1125 must cover at least 60 percent of the leaf width where more than 60 people use the escape route. The force a door needs stays capped: 30 N over the first 30 degrees of swing, then 22.5 N once past that point. Under TS 007, a 2 star handle fitted with a 1 star cylinder reaches 3 star protection. The hardware guide and the closers guide cover the choice in detail.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

What to name in the specification before ordering

A specification that lists rating, class, size, finish and hardware for every opening leaves the supplier nothing to guess, and it gives the buyer a line to check at handover. The table that follows sets a starting point with five openings seen often across Bristol. Final figures come from the survey, because wall build up and door traffic can lift a choice a class or drop it one.

Opening in Bristol Fire rating Forced entry class Hardware to name
Hospital ward corridor EI 60 SR2, class B3 Closer EN 3, panic bar
Office stair door EI 30 SR2, class B3 Closer EN 3, lever handles
Retail stockroom EI 60 SR2, class B3 3 star cylinder set, closer EN 3
Plant room at Temple Meads or the airport EI 60 SR2, class B3 3 star cylinder set, hinges grade 14
University lecture block corridor EI 30 SR2, class B3 Closer EN 3, push pad

From survey to handover in Bristol

The order runs in five stages. A survey visit records the opening sizes, the wall build up and the way people use each door, and the specification that follows names the rating, the class, the finish and the hardware for every opening. Fitting sets the frame square and true and the closer to the force the opening needs, and the gaps are checked at 4 mm.

Handover closes the job with a pack holding test evidence, a hardware schedule and care notes for every door, and the buyer checks rating and class on the order against the labels on the leaf. The certification guide explains what the test evidence should show, and the snagging checks guide lists what to look for before signing.

A fire door that never shuts is a fire door in name only. The closer, the seals and the gaps decide the rating in use, not the label on the leaf.

Frequently asked questions

How long does an SR2 fire door hold back fire in a Bristol hospital?

It depends on the rating named in the specification, which runs from EI 30 to EI 120. The compartment line decides the figure, and the survey fixes the rating for each opening before the order is placed.

What does SR2 mean, and what is class B3?

SR2 is the rating under LPS 1175, and B3 is its class, with a three minute delay against the tool set for that class. SR1 sits below it and SR3 and SR4 sit above it.

Do I need a new frame with the leaf?

The rating applies to the leaf, the frame and the seals together, so the existing frame is checked before reuse. A frame that is out of square or damaged is replaced, because a new leaf in a weak frame holds neither the fire rating nor the forced entry class.

How wide can the gap around the leaf be?

The gap is kept at 4 mm around the leaf. Intumescent seals expand at about 200 to 250 degrees to close that gap in a fire, and a smoke seal to Sa or S200 keeps cold smoke from passing the closed door. The gaps are checked at handover.

SR2 fire doors in Bristol, surveyed and fitted

Send the opening sizes, the rating wanted and a photograph of each frame to [email protected]. We reply inside one working day, naming an indicative price and the next step. ArxBridge, Saffron Road, Romford, Essex RM5 3ES, for enquiries. Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.