Fire · EI 30 to EI 120
SR2 fire doors in Sheffield
SR2 fire doors in Sheffield for hospitals, universities, stadiums and shops, with fire and forced entry ratings named for every opening in the city.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Sheffield
Get a free quote in Sheffield
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Sheffield
What we supply in Sheffield
SR2 fire doors in Sheffield give a hospital corridor, a university laboratory or a stadium concourse one leaf that resists fire and resists a forced entry attempt. The leaf carries a fire class and an SR2 rating together, so a door on a fire line also stands up to a three minute attack with the B3 tool set.
Sheffield asks for that pair of ratings in more places than a single building type. Northern General Hospital and Royal Hallamshire Hospital run wards, corridors and plant rooms, and a fire door there must also keep an unauthorised person out of a store or a service room. Sheffield Children’s Hospital holds wards and corridors with the same need. The University of Sheffield holds laboratories and workshops, and Sheffield Hallam University holds laboratories and stores with the same need, while Meadowhall, The Moor and Fargate hold retail units and service corridors where stock rooms sit behind a public frontage. Physical security in Sheffield gives the wider city picture, and the door specification follows the building it serves.
A buyer should name both ratings in the order, not leave one to a brochure line. SR2 means three minutes against tool set B3, and the fire class runs from EI 30 to EI 120 under the fire test, with E and EW classes named where the brief asks for them. The LPS 1175 page gives the four ratings and the tool set behind each one, and the fire ratings page names the fire classes in the same way.
Where the doors go in Sheffield
Bramall Lane, Hillsborough and Utilita Arena Sheffield hold concourses, hospitality rooms and back of house stores where a door must hold a crowd route shut in a fire and keep a service room closed to the public. Martyn’s Law puts venues with a capacity of 800 or more in the enhanced tier, and venues from 200 to 799 in the standard tier. Royal Assent came on 3 April 2025, and the go live date is expected in spring 2027, so a stadium or arena brief should name the tier the venue falls in. The Martyn’s Law page names both tiers and the dates behind them, and the stadium fire door rules cover the doors on a match day route.
Attercliffe and Sheffield Forgemasters hold works and workshops where plant rooms, stores and control rooms sit beside production floors, and Kelham Island holds converted workshops and small makers where an old opening takes a new steel leaf. Sheffield station holds retail units and service rooms that trade around train times, and Ecclesall Road holds shops, clinics and offices where a rear door protects a stock room or a records store. The hospital fire door rules cover the ward and corridor doors in more depth.
Two ratings on one leaf
The specification prescribes LPS 1175 Issue 8.2 (September 2024) behind the fire rating, letting one schedule carry both test results. SR1 stands at one minute against tool set A1, SR2 at three minutes against B3, SR3 at five minutes against C5 and SR4 at ten minutes against D10, so the buyer names the class the opening needs and the test behind it.
The test record references BS EN 1634-1:2014+A1:2018 accordingly, and the rating applies to leaf, frame and seals together. A leaf tested on its own tells only part of the story, because the frame, the seals and the ironmongery decide whether the rating holds in the wall. The dual certification guide covers how the two ratings sit on one leaf, and the keeping dual certification valid guide covers the checks that keep both ratings standing after fitting.
Leaf, frame, seals and hardware
Gaps around a fire door leaf should stay at 4 mm, checked with a gauge at the head and both jambs, because a wide gap lets smoke and flame pass the leaf before the seals act. Intumescent seals swell shut once the heat passes 200 degrees, closing the gap well before 250 degrees, and the seal type should match the fire class named in the order. The gaps guide covers the check in detail, and the seals guide covers the seal types.
Hardware should match the leaf weight and the fire class. A closer sized to BS EN 1154 runs from power size EN 1 up to EN 7, and a fire door takes at least EN 3. Hinges should meet BS EN 1935, with grade 13 rated for a 120 kg leaf over 200,000 cycles and grade 14 rated for a 160 kg leaf over the same count. The hardware guide covers locks, closers and hinges, and the closers guide covers the closer choice.
A door that many people use in a day should open with ease. The effort to open a door is set by BS 8300 and Approved Document M: no more than 30 N over the opening arc to 30 degrees, then no more than 22.5 N past that point. A heavy leaf needs a closer and hinges that keep the push inside those limits. PAS 24 is a residential test, so a commercial door specification in Sheffield leaves it out.
| Site | Fire class | SR class | Hardware note |
|---|---|---|---|
| Hospital ward corridor | EI 60 | SR2 | Closer EN 3, lever handle |
| Meadowhall stock room | EI 30 | SR2 | Lock and closer matched to leaf |
| Stadium concourse | EI 60 | SR2 | Panic hardware on escape route |
| Kelham Island workshop | EI 30 | SR2 | Hinges grade 13, closer EN 3 |
Survey, fitting and handover in Sheffield
Each opening is measured first: the width, the height and the wall depth, with a note of the floor finish and the headroom, and a photograph of the frame and the wall around it, so the written specification names the leaf size, the fire rating and the SR rating for every door. Steel leaves for the same openings are covered on the steel fire doors in Sheffield page.
Paperwork for the order is held at the Romford base on Saffron Road, Romford, Essex RM5 3ES where the schedule is kept. The handover covers the closer, the lock and the seal check, so the site team knows how the door closes and what to look for at each inspection. Maintenance visits keep the gaps and the seals in order after fitting.
A fire door that is wedged open or held back with a box loses both ratings at once. The leaf must close fully on its closer every time, because the fire class and the SR class both depend on a leaf that sits shut in its frame.
Questions about SR2 fire doors in Sheffield
What fire class should a hospital corridor door carry in Sheffield?
The fire strategy for the building gives the class for every opening, and the order repeats it. Corridor doors in a hospital often sit at EI 60, while a store or a plant room door may sit at EI 30 or EI 60, and the written specification names the class for every door on the job.
Does SR2 mean the door resists attack for three minutes?
Yes. SR2 means three minutes against tool set B3, with the leaf, frame, lock and fixings tested as one set. A higher class, SR3 at five minutes against C5, suits an opening where the risk or the value behind the door asks for more time.
Can an SR2 fire door be fitted into an old frame on Ecclesall Road or in Kelham Island?
An old frame takes a new leaf only where the frame is square, sound and deep enough for the seals and the fixings the rating needs. The survey measures the frame before any leaf is ordered, and a frame that falls short is replaced with the leaf.
Who checks the gaps and seals after fitting?
The site team checks the 4 mm gaps and the seals at handover, and each maintenance visit repeats the check. A seal that is cut, painted over or missing should be replaced before the door is used again.
Share the opening measurements at [email protected] and expect a written answer within one working day, giving the fire rating and the SR rating for each door.
Other areas
SR2 fire doors in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.