Certified physical security

ArxBridge
Port-side commercial buildings with steel doors in Southampton

Fire · EI 30 to EI 120

SR2 Fire Doors in Southampton

SR2 fire doors in Southampton with a fire rating and forced entry resistance on one doorset, for hospitals, cruise terminals, shops and university blocks.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Southampton
Prefer to talk?+44 7352 267239

Get a free quote in Southampton

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Southampton

What we supply in Southampton

More on this

In Southampton, SR2 fire doors put two duties on one doorset: hold fire back for the time the fire strategy asks for, and resist forced entry for three minutes against the tool set named in the security standard. That pair suits buildings where both risks meet, and Southampton has many of them, from cruise terminals and cargo quays at the docks to wards at Southampton General Hospital, shops at Westquay and Ocean Village, and teaching blocks at the city’s two universities.

One rating seldom covers a Southampton site by itself. A hospital corridor door must hold fire and smoke yet keep a pharmacy or records store locked, a cruise terminal door must serve crowds at sailing time yet guard the rooms behind it, and a shopping centre door must let staff use a service corridor all day yet keep the stock room shut. For gates, shutters and barriers elsewhere around Southampton, the city overview of rated physical security work gathers them in one place.

Port and cruise terminalsTerminal doors, stores and plant rooms
Hospital and healthWard doors, pharmacies and stores
Retail and leisureWestquay, Ocean Village and back of house
Universities and student blocksLabs, plant rooms and halls

Two ratings on one Southampton doorset

An SR2 fire door carries two ratings on the same doorset, and each rating rests on its own test evidence. The minutes quoted for fire resistance rest on a furnace test run on the whole doorset per BS EN 1634-1:2014+A1:2018. Fire resistance is usually classed E, EW or EI, with the time in minutes set by the fire strategy for that wing of the building. Class B3, the SR2 forced entry mark, is listed under the current issue, LPS 1175 Issue 8.2 (September 2024), which names tool set B for a three minute attack. It resists three minutes of attack with tool set B. To read how a furnace run turns into a minute figure, open the fire ratings page; the LPS 1175 standard page then sets out each SR class beside the tools its test uses.

Both ratings have to name the same doorset. A fire certificate for a leaf by itself says nothing about the frame, the lock and the hinges that the SR2 test covers, and an SR2 certificate says nothing about the seals and the closer that the fire test covers. Paperwork for both sides is covered in two places: the dual certification guide pairs the fire and forced entry evidence, while the fire door certification guide notes the handover papers worth requesting.

Southampton buildings where both ratings meet

Hospital buildings ask for the pair most often. Corridor doors at Southampton General Hospital separate wards and treatment rooms from escape routes, so the fire rating matters at every hour, while pharmacy doors, records stores and plant rooms need the SR2 rating to keep medicines, notes and equipment behind a lock. The hospital fire door guide sets out what a hospital asks of its doors.

Port and cruise terminal buildings ask for the pair where crowds meet back of house rooms. A terminal door that serves passengers at sailing time must hold fire on an escape route, while the stores, plant rooms and offices behind it need forced entry resistance once the terminal closes. The port fire door guide sets out the pattern for port buildings.

Retail and university buildings ask for the pair on service corridors and stores. Shops at Westquay and Ocean Village need fire doors on the routes staff use between the shop floor and the stock room, and those same doors need SR2 where the stock room holds high value goods. Teaching blocks, laboratories and student accommodation at the University of Southampton and Southampton Solent University need the same mix on plant rooms, server rooms and stores. The shopping centre fire door guide and the student accommodation fire door guide give the pattern for each.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Typical ratings by Southampton site

Use the rows as a first guide for the survey talk. The fire strategy and the risk assessment settle the final ratings for each opening, and nothing is ordered until the specification is agreed.

Southampton site Door position Fire rating SR2 and hardware
Hospital wards and corridors Corridor doors and ward entrances E or EI, 30 or 60 minutes SR2, lever handles and closers
Pharmacy and records stores Store and records rooms E or EI, 30 minutes SR2, high security lock
Cruise terminals and docks Terminal doors, stores and plant rooms E or EI, 30 to 60 minutes SR2, heavy duty hinges
Retail service corridors Stock rooms and service corridors E or EI, 30 minutes SR2, access control ready
Universities and student blocks Labs, plant rooms and stores E or EI, 30 minutes SR2, hard wearing finish

Setting down an SR2 specification

Start from the opening and the two ratings it needs. For every door, write down its measured size, the fire class and time, the SR class, and the hardware, with the test papers for each rating kept beside them in the specification. What moves the price of each doorset is traced in the fire door cost factors guide, and the guide to specifying security doors runs through the points to settle before a quote.

Cost the whole unit together, leaf, frame, seals, hinges, lock, closer and finish, so the price covers everything, not the leaf on its own. The closer and the seals belong to the fire rating, the lock and the hinges belong to the SR rating, and a quote that prices the leaf alone leaves both ratings short. Where access control is fitted, name the reader, the cable route and the power feed beside it.

Survey, making and fitting in Southampton

Every job begins with a survey of each opening, the wall make-up and the way staff move through the door during the day. From the survey come the leaf, frame and threshold sizes, the fire class and the SR class for each opening, and the doorset is then made to the specification the survey agreed.

The acceptance and snagging guide lists the handover checks that run before sign off, and the fire door inspection checklist lists the checks for seals, gaps and closers.

Through the quote form, pass on each opening size together with the rating its door must hold. A written answer lands by the end of the next working day, holding the specification and a price figure for each doorset.

A note before you accept a quote

Ask for the test evidence for both ratings before you accept a quote. A fire certificate on its own says nothing about forced entry, and an SR2 certificate on its own says nothing about fire, so the two papers must name the same doorset.

SR2 fire doors in Southampton: questions

Can one doorset hold both a fire rating and SR2?

Yes. One doorset can hold both, built and tested for the two ratings together. For fire, the doorset passed BS EN 1634-1:2014+A1:2018, while the forced entry side rates SR2, class B3 per LPS 1175 Issue 8.2 (September 2024). Ask to see the test evidence for each rating, and check that both name the same doorset.

Which fire rating does a hospital corridor door need?

The fire strategy for the building decides it, usually E or EI with a time in minutes. The corridor door holds fire and smoke on an escape route, so the class and the time are set by the strategy, not by the security rating.

Does SR2 change the way a fire door closes?

It can change the hardware, not the job of the closer. The closer and the seals still shut the door after every pass, while the lock and the hinges carry the SR2 rating. The two sets of hardware are chosen together, so the door still closes firmly and still resists attack.

How long does an SR2 fire door job take from survey to fitting?

The survey and the specification come first, the doorset is made to those figures, and fitting follows the programme agreed at the start. The making time depends on the size of the order and the hardware on each door.

SR2 fire doors needed for a Southampton hospital, terminal, shop or university block? Pass on the sizes and ratings for the openings on your list, and each doorset gets its own price figure in the reply.

Ask for a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.