Fire · EI 30 to EI 120
SR2 Fire Doors in Birmingham
SR2 fire doors for Birmingham offices, hospitals, schools and shops, dual rated for forced entry and fire, with survey, specification and fitting.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Birmingham
Get a free quote in Birmingham
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Birmingham
What we supply in Birmingham
One leaf can hold back fire and forced entry together, and that is what a dual rated doorset is for. In Birmingham, an SR2 fire door puts the pair into a single leaf, so hospital corridors, school entrances and shop back doors each answer the fire plan and the security plan with no second door needed.
An SR2 fire door in Birmingham joins an SR2 forced entry class to a fire class. Each rating wants its own test evidence, and both sit in the same file. Door, frame, seals, closer and lock go through the test as one set, so any change to one part wants a fresh check against the evidence. A closer swapped for another model breaks that set, even when the new one looks the same.
New Street offices, Queen Elizabeth wards, University of Birmingham classrooms and Bullring shopfronts each draw a different fire line and face a different attack risk. What a door needs follows the room it guards and the people who pass through it. The Birmingham area page puts each of those uses on the city map.
Birmingham buildings that take an SR2 fire door
Stair cores and lift lobbies round Colmore Row and Snow Hill want a door that holds a fire line and stands up to forced entry after hours. Closer, lock and seals all earn a line in the specification beside the rating: the closer shuts the leaf each time, the lock holds it, and the seals sit tight against smoke. The office fire door rules page has what a building manager owes those doors.
At Queen Elizabeth Hospital and the clinics across the city, corridors want a door that lets beds and trolleys through fast and still shuts on its own at the alarm. A vision panel lets staff see what waits beyond, and the hardware must suit hands that are often full. The hospital fire door rules page has the fire plan lines that run through wards and departments.
Schools, the University of Birmingham and Bullring shops each use doors in their own way. Bags and feet knock a school entrance all day, students flow through a university corridor without a break, and a shop back door guards stock while goods move through it. The education sector page follows a school and a campus from gate to classroom.
The two ratings behind one doorset
The specification bears LPS 1175 Issue 8.2 (September 2024) to the front of the file. B3 pairs with SR2, A1 pairs with SR1, C5 pairs with SR3 and D10 pairs with SR4. Every class faced its own tool set in the test, and the LPS 1175 page puts each class beside the tools of its test. The SR2 SR3 SR4 comparison page puts the three classes beside the risk at each opening.
Fire has its own test evidence, and it comes next. The fire section puts BS EN 1634-1:2014+A1:2018 from the furnace test first in the file, with the class in E, EW or EI form, from 30 to 120, written beside each door. The fire ratings page tells what each class holds back, and the dual certification guide puts the fire class and the security class together in one doorset.
PAS 24 was written for houses, not for commercial doors. Its doorsets are residential ones only, so a Birmingham office, hospital or school named beside it gets the wrong standard in the file. The dual certified doors guide has what keeps both ratings live after handover: leaf edge gaps, seals and closer, each checked in turn.
A quick reference for SR2 fire doors
Take the table as a rough pointer only. Fire plan plus opening measure fix the fire class and the security class for each door. People behind it, shut hours and the risk on the far side all feed into that choice.
| Birmingham building | Where the door sits | Fire | Security |
|---|---|---|---|
| Office stair core, Colmore Row | Stair door in daily use | EI 60 | SR2, class B3 |
| Hospital corridor, Queen Elizabeth Hospital | Corridor door, vision panel fitted | EI 60 | SR2, class B3 |
| School entrance, city school | Main entrance | EI 30 | SR2, class B3 |
| Shop back door, Bullring | Stock room | EI 60 | SR2, class B3 |
| Plant room, university campus | Plant room | EI 120 | SR2, class B3 |
Writing the SR2 fire door specification
Open with the fire line and the risk at the door. The fire plan fixes the class for the opening, the risk fixes the SR class, and both classes share the same lines of the specification, test evidence beside each one. The fire door certification page has the evidence a buyer ought to ask for ahead of ordering.
Gaps, seals and hardware get settled in one pass. Leaf edge gap, intumescent seal, closer, lock and any vision panel all belong to the tested set, so swapping any one of them wants a check against the evidence. A hinge from another set breaks it the same way. The fire door gaps page has the limits for the leaf edge, and the fire door hardware page has the closer, hinges and lock as one set.
End with the face and the use. Hospital doors want a face that wipes clean, school doors want a face that takes knocks, and office doors want a face that suits the floor they open onto. The healthcare sector page follows hospital doors from ward to plant room, and the face ought to suit the room while the seals and the closer stay on show.
From first measure to handover: SR2 fire doors
A measure at the opening starts the job. The surveyor takes width, height and the state of the frame, looks at the fire line the plan draws through the building, and notes how much traffic the door takes each day. Photos plus a scaled drawing of each opening back the specification up.
Next, the written record fixes each door’s fire class and SR class, leaf, frame, seals, closer, lock and vision panel beside them. The hours stay the ones the site agrees, and wards, classrooms and trading stay in use.
Handover ends the job. The client takes the keys with the test evidence for both ratings, the O and M manual, the maintenance scope. Routine checks after handover sit with the maintenance service, so each rated door keeps working. Send the sizes and classes to [email protected], or hand the same two items to the quote form. A written answer arrives before the next working day closes. It holds the specification, the rating check and a price band.
Hold off on any hardware swap after handover until the evidence has been checked. A closer, lock or seal outside the tested set can undo both ratings, so check each change against the file first.
SR2 fire doors in Birmingham: questions
What does SR2 mean on a fire door?
It means the doorset stood up to the class B3 tool attack set, under the current forced entry standard, and it holds a fire class of its own too. Each rating was tested on its own and written beside the other, so the file wants evidence for both.
Does an SR2 door always need a fire rating?
No. A door on an outside wall, or in a line the fire plan leaves out, often wants no fire class at all. A door across a compartment line always wants one. The fire plan draws the line, and the class goes into the specification for that opening.
Can an SR2 fire door suit a school entrance?
Yes, when the specification states the use. A school entrance takes heavy traffic each day, so leaf, closer and hardware want choosing for that wear. Gaps and seals get checked at fitting, then again at each routine visit.
How often should an SR2 fire door be checked?
At the routine visits the maintenance scope fixes, and after any knock, repair or hardware change. Each visit looks at the gaps, the seals, the closer and the lock. Any fault found gets put right before the door is left in use.
SR2 fire doors planned for a Birmingham office, hospital, school or shop? Send the opening sizes and the classes wanted. Expect a specification back before the next working day ends.
Other areas
SR2 fire doors in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.