Fire · EI 30 to EI 120
SR2 Fire Doors in Cambridge
SR2 fire doors for Cambridge colleges, hospitals, laboratories and stations: forced entry and fire resistance in one tested steel doorset, made to size.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Cambridge
Get a free quote in Cambridge
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Cambridge
What we supply in Cambridge
Some Cambridge doors carry two duties in a single opening, and no second leaf can take one of them away. A door on an escape route that guards a laboratory, a plant room or a records store must hold fire in its compartment and slow a forced entry attempt, and SR2 fire doors are the doorsets tested for both duties, leaf, frame and hardware as one. One opening, one doorset, and a test record for each duty.
Cambridge gives the pair of duties plenty of work. Colleges of the University of Cambridge hold teaching rooms, libraries, accommodation and chapels, Addenbrooke’s Hospital and the Cambridge Biomedical Campus hold wards, laboratories and plant rooms, and Cambridge Science Park holds research and office buildings. Cambridge station brings a public entrance busy with every train, and the centre around King’s College Chapel, the River Cam and the Fitzwilliam Museum holds shops, offices and museums. Physical security in Cambridge maps rated protection across the city, and the doorsets on this page sit where the two duties meet in one opening.
In this doorset the forced entry rating is SR2, class B3, held for three minutes against the tool set the standard names. The fire rating runs E, EW or EI, at half an hour, one hour or two hours. Both duties rest on test evidence for the same build, leaf, frame and hardware together, and the buyer reads that evidence at handover to prove the door on the pallet is the door the specification named. Later inspections return to the same record, so the two ratings stand or fall on papers that match the fitted product.
College quads, wards and laboratories: where Cambridge needs both ratings
Colleges hold the clearest case. One college door can stand on an escape route from a stair, guard a library or a laboratory store, and face a quad where the public walks, all at once. Old college walls are thick and openings uneven, so the surveyor measures each opening where it stands and the doorset is made for those measurements, not for a size on an old plan. Where a frontage is listed, the specification records the limit, so the workshop builds for the opening as found.
Addenbrooke’s Hospital and the Cambridge Biomedical Campus hold wards, laboratories and plant rooms where doors carry beds, trolleys and kit all day. A door out of action there blocks a route clinicians count on, so fitting is set around ward work, the clear opening takes a bed, and the threshold lets a wheel cross without a jolt.
Cambridge Science Park holds research and office buildings where laboratories, plant rooms and stores sit behind doors guarding kit and records, and Cambridge station holds a public entrance that fills and empties with each train. Around King’s College Chapel, the River Cam and the Fitzwilliam Museum, shops, offices and museums hold doors that face the street and guard a store at the same time. In each of those buildings a door holding only one of the two ratings leaves the opening half guarded, and the specification names both together so the gap never opens.
Reading the two ratings on one doorset
The forced entry class and the fire class are named side by side on the specification, and the test record behind each is read at handover. Orders placed before LPS 1175 Issue 8.2 (September 2024) had been published used the earlier issue, and those doorsets are judged against the class named on their own test record. The fire grades behind BS EN 1634-1:2014+A1:2018 came from furnace tests on a doorset built as it would be fitted, leaf, seals and hardware together. For the classes, see our LPS 1175 standard page and the fire ratings page, and the guide on specifying fire doors for a housing tender explains how a fire class goes into a tender specification.
Hardware belongs to the rating, not beside it. Closer, lock, hinges and seals are the set the test record names, and swapping any one of them after fitting can throw the rating into doubt. The keeping the rating valid guide explains how both ratings stay in force after fitting, and the CDM 2015 duties guide lays out what buyer and contractor each owe while work runs on site.
The table below names the handover checks and what each one proves.
| Handover check | Look for | Proves |
|---|---|---|
| Test record | Class and fire grade on the same build | Both ratings on one doorset |
| Leaf and frame | Sizes against the survey sheet | Product fits the opening |
| Seals | Seated all round the frame | Fire and smoke held back |
| Hardware | Closer, lock and hinges as on the record | Tested set fitted |
| Closing | Door shuts fully on its closer | Rating works in use |
How an SR2 fire door job runs in Cambridge
Work begins with a message naming the building, the openings and the ratings each opening must carry, and the first reply lands inside a working day carrying a survey date. The surveyor measures each opening where it stands, notes the wall behind the frame and the state of the reveal, and photographs the uneven points in old college walls so the workshop builds for the opening in front of it. The specification returns to the buyer for sign-off before any metal is cut, because paper is cheap to change and a finished doorset is not.
Fitting falls to the installation service, drawings to the design service where the buyer needs them, and the handover notes follow the commissioning and handover guide. The maintenance service looks after the checks that keep both ratings in force once the job is signed off.
After handover, check the test record before swapping a closer or a lock. The hardware set belongs to the rating, and a part from another range may hold the door open or leave the leaf unproven, which loses a rating that was paid for faster than anything else.
Questions Cambridge buyers ask about SR2 fire doors
Can an SR2 fire door stand on an escape route?
Yes, when the specification names the fire class for that route and the test record covers the doorset as built. The door holds fire in its compartment while people leave, and the forced entry rating guards the same opening once the building is shut. Route, fire class and SR class are named together on the specification, so none of the three is missed.
Does a listed college frontage block a new steel door?
Not always, and the buyer asks the planning authority before ordering. Where consent is needed, the specification records the limit, the drawings show the opening as measured, and the finish is chosen to sit beside the existing frontage. The survey notes the state of the opening, so the consent papers and the workshop drawings agree.
What if the closer or the lock is swapped later?
The rating can fall into doubt, because the test record names the hardware set the doorset was tested with. Any swap is judged against that record first, and a part from outside the tested set needs evidence of its own before it goes on. The handover notes list the hardware set, so a later swap can be judged against the record.
How are uneven openings in old college buildings measured?
The surveyor takes the opening at several points and builds to the worst of them, not to an average. The frame is made to fit that point, the drawings show the packers and the seal positions the fitter needs, and the doorset is measured against the survey sheet when it reaches the site.
Ask for a quote for SR2 fire doors in Cambridge. Send the building, the openings and the two ratings each opening must carry to [email protected], or through our contact page. ArxBridge is based on Saffron Road, Romford, Essex RM5 3ES, and the first answer lands inside one working day.
Other areas
SR2 fire doors in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.