Fire · EI 30 to EI 120
SR2 Fire Doors in Oxford
SR2 fire doors in Oxford that hold three minutes against the B3 tool set and carry a fire rating under BS EN 1634-1, with 4 mm leaf gaps, plus a closer.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Oxford
Get a free quote in Oxford
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Oxford
What we supply in Oxford
An SR2 fire door in Oxford holds two roles on one leaf, and the buyer should read them apart. The SR2 grade measures the leaf against forced entry, while the fire rating measures the same leaf against fire, and each role reads from its own test. A leaf that holds one role and fails the other leaves the building short on the side that was never checked.
The forced entry side reads from LPS 1175. SR2 sits at B3 on that scale, which gives the leaf three minutes of hold against the B3 tool set, and the scale runs from A1 at the low end through H20 at the top. A college gatehouse, a hospital ward door or a museum store door that faces a forced entry risk takes the grade that matches the risk, and the grade goes into the specification by name.
Oxford puts an SR2 fire door to work in many kinds of building. Gatehouses and libraries in the colleges of the University of Oxford need a leaf that guards books and stores, the John Radcliffe Hospital needs ward and department doors that hold fire between wards, and Westgate Oxford needs store doors behind its shopfronts. The Ashmolean Museum and the Bodleian Library guard galleries and reading rooms, while the Covered Market, Oxford Castle and Oxford station hold doors in busy public fabric. The physical security in Oxford page sets the colleges, the hospital and the market of the city in one place.
Two roles on one Oxford leaf
The leaf carries a forced entry grade and a fire rating, and the two never stand in for each other. The SR2 grade gives the leaf three minutes of hold under the B3 tool set, while the fire rating says the leaf holds fire for its class time, and a specification that names only one of them leaves the other side open. Name both in the specification, and check the test evidence for both before the leaf is ordered.
The specification centres LPS 1175 Issue 8.2 (September 2024) centring on the grade the leaf was built to, and the LPS 1175 page gives each grade with its tool set and its minutes.
A fire rating by itself says nothing about forced entry. A leaf with a strong fire rating and no SR grade will hold fire yet give way to tools, and a leaf with a strong SR grade and no fire rating will hold tools yet let fire through. The buyer who needs both roles should ask for one leaf that carries both tests, and the test evidence should name the leaf build, the frame, the seals and the ironmongery for each role. The fire door certification notes cover the evidence a fire leaf should carry.
Fire classes and leaf gaps on an SR2 door
The fire side of the leaf reads from BS EN 1634-1, with classes E, EW and EI that run for 30 minutes at the low end and 120 minutes at the top. E holds the leaf against flames, EW caps the heat that passes through, and EI caps the heat at the face that stays away from the fire. The class and its minutes go into the specification, and the fire ratings page shows the classes a buyer will meet.
Leaf gaps matter as much as the class. The gap at the head and at the jambs should stay inside 4 mm, since a wide gap lets smoke and heat pass a leaf that holds its class on paper. The engineer checks the gap at three points down each side, and a gap that has grown gets the leaf rehung before the next check. The fire door gaps notes list the same limits for a fire leaf.
The closer on the leaf should be at least power size 3 under BS EN 1154, with the sweep and latch speeds set so the leaf meets its latch each time. A closer that leaves the leaf short of its latch leaves the fire rating open, and the fire door closers notes list the power sizes a fire leaf takes.
Where an SR2 fire door stands in Oxford
College doors ask first. Gatehouses and libraries in the colleges of the University of Oxford guard rooms full of books and stores, and a leaf there takes the SR2 grade for the forced entry risk and the fire class for the rooms behind it. The Bodleian Library holds doors of the same kind, with store doors behind the reading rooms that take the same pair of roles.
Hospital and retail doors ask next. Ward doors and department doors at the John Radcliffe Hospital hold fire between wards while they guard drugs and equipment stores, and Westgate Oxford holds store doors behind shopfronts that take the same pair of roles. The Ashmolean Museum holds store doors behind its galleries, Oxford station holds doors on its concourse and in its back rooms, while the Covered Market and Oxford Castle hold doors in older fabric where the leaf must fit the opening as found. The dual certification notes cover a leaf that carries both roles, and the security gates in Oxford name the gates that stand guard on the same sites.
Oxford sites and the SR2 door each one takes
| Oxford place | Leaf type | Leaf notes |
|---|---|---|
| University of Oxford colleges | Gatehouse and library doors | SR2 leaf with a fire class for the rooms behind |
| Bodleian Library | Store doors behind reading rooms | Leaf sized to the opening as found, seals checked at fitting |
| John Radcliffe Hospital | Ward and department doors | Fire class between wards, SR2 grade on the store doors |
| Westgate Oxford | Store doors behind shopfronts | Leaf that guards stock and holds fire between units |
| Ashmolean Museum | Store doors behind galleries | SR2 grade on the store leaf, fire class for the gallery behind |
Use the rows to shortlist the leaf build, then let the survey fix the class and the grade for each door.
From survey to handover in Oxford
Each opening gets measured before a leaf is ordered. The engineer takes the sizes of each opening, the frame depths and the wall build, and notes the use of each room and who walks through it, and fixes the leaf build, the grade, the fire class and the closer for each door. The fire compartmentation notes show how a leaf fits the wall that holds the fire back.
Other doors on the same building often run beside an SR2 fire door. The fire rated steel doors in Oxford hold fire without the SR grade, the security doors in Oxford guard the same building, and the installation in Oxford notes cover how the leaf goes in. The SR2 fire doors parent page gives the full product picture.
Deeper physical measures are asked of the enhanced tier, which covers a hall in Oxford that holds 800 people or more. A hall with 200 to 799 people inside counts as standard tier.
Ask for the door drawings and the fire test record at the catch Saffron Road, Romford, Essex RM5 3ES. Post first with the leaf sizes and the rating ready.
Email [email protected] for design notes on the leaf build, the closer and the intumescent seals, and the reply gives the survey date and says what the survey file holds.
A leaf that holds one role and fails the other leaves the building short, so check the SR grade and the fire class as one set, never one alone.
Oxford buyers ask about SR2 fire doors
Does an SR2 grade also give a door its fire rating?
No. The SR2 grade measures the leaf against forced entry for three minutes at B3, while the fire rating measures the same leaf against fire under BS EN 1634-1. A leaf that needs both roles should carry test evidence for both.
What fire classes can an SR2 door carry?
E, EW and EI, with 30 minutes at the low end and 120 minutes at the top. E stops flames, EW limits heat passing through, and EI limits heat on the side away from the fire.
What gap should an SR2 fire door hold?
Inside 4 mm at the head and the jambs. A gap past that mark lets smoke and heat pass a leaf that holds its class on paper, so the gap gets checked at three points down each side.
What closer should an SR2 fire door take?
A closer of power size 3 or more under BS EN 1154, with sweep and latch speeds that bring the leaf fully home to the latch. A closer that leaves the leaf short of its latch leaves the fire rating open.