Fire · EI 30 to EI 120
SR2 fire doors in Leeds
SR2 fire doors for Leeds hospitals, universities, stadiums and offices, dual rated for fire and forced entry, with a written specification per doorset.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Leeds
Get a free quote in Leeds
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Leeds
What we supply in Leeds
SR2 fire doors in Leeds give one doorset two jobs, holding back fire and smoke through its rated time and holding back a forced entry attempt for three minutes. Leaf, frame, seals and hardware pass through one test as a doorset, so the fire rating and the SR2 rating belong to the same set, not to separate parts. A Leeds buyer orders this door where a fire compartment line also needs a forced entry rating, and where one door must pass both tests.
Leeds General Infirmary takes this door for ward corridors and pharmacy stores on compartment lines, and St James’s University Hospital takes it for the same corridors and stores, while at the University of Leeds, alongside Leeds Beckett University, it goes where halls of residence and plant rooms sit behind doors that face open circulation, and at Elland Road and Headingley Stadium it goes where concourses and cash offices sit behind doors that face crowds. The First Direct Arena takes it where back of house corridors meet public areas, Trinity Leeds and the Victoria Quarter take it where service corridors meet retail floors, and Leeds Station takes it where plant rooms and back of house areas sit beside the concourse. Leeds Bradford Airport takes it where baggage halls and offices sit behind doors that face public circulation, Kirkgate Market takes it where storage areas meet trading floors, and the Royal Armouries takes it where stores and galleries sit behind doors that face visitors.
ArxBridge supplies SR2 fire doors for Leeds hospitals, universities, stadiums and offices, with each opening measured first and each doorset built to the ratings the site needs. The buyer agrees the fire rating and the SR class before anything is ordered, with the hardware agreed at the same time. The physical security in Leeds page gives the Leeds picture in full, and the matching steel door range sits on the fire rated steel doors page.
Leeds buildings that need SR2 fire doors
Ward corridors at Leeds General Infirmary sit on compartment lines that need a door that carries a fire rating with a forced entry class in one set, and ward corridors at St James’s University Hospital sit on the same lines. A pharmacy store that holds controlled stock needs the same door, and a corridor that carries patients, beds and trolleys needs a door that opens with a light push and closes firm behind them. The fire door regulations for hospitals guide lists the rules for ward and pharmacy doors, and the fire door regulations for A and E departments guide covers the rules for emergency department doors.
Halls of residence at the University of Leeds, alongside Leeds Beckett University, need this door where bedrooms open onto corridors that form part of the escape route, and plant rooms need it where services pass through a compartment wall. Concourse doors at Elland Road and Headingley Stadium face crowds on match days, and back of house corridors at the First Direct Arena meet public areas where a door must hold both ratings. The fire door regulations for stadiums guide gives the rules for concourse and back of house doors, and the fire door regulations for student housing guide covers the rules for halls of residence.
Service corridors at Trinity Leeds and the Victoria Quarter meet retail floors where a door must hold fire back and keep intruders out, and plant rooms at Leeds Station sit beside a concourse that stays busy all day. Baggage halls at Leeds Bradford Airport need the same door where offices sit behind doors that face public circulation, storage areas at Kirkgate Market meet trading floors, and stores at the Royal Armouries sit behind doors that face visitors. The fire door regulations for shopping centres guide covers the rules for service corridor doors, and the fire door regulations for airports guide gives the rules for baggage hall and office doors.
What a Leeds SR2 fire door usually covers
Each row pairs a Leeds building with where the door sits and the ratings that opening calls for.
| Building in Leeds | Where the door sits | Fire and SR2 ratings | Extra help |
|---|---|---|---|
| Leeds General Infirmary ward corridor | Corridor on a compartment line | SR2, fire E, EW and EI to 120 minutes | Closer set for easy opening |
| University of Leeds hall of residence | Bedroom corridor door | SR2 with fire ratings E, EW, EI to 120 minutes | Seals checked at handover |
| Elland Road concourse | Concourse door facing crowds | SR2 and fire E, EW and EI, from 30 minutes | Hardware to match the corridor |
| Trinity Leeds service corridor | Service corridor to retail floor | SR2, E, EW and EI fire ratings to 120 minutes | Signage fitted with the door |
| Leeds Station plant room | Plant room beside the concourse | SR2 with E, EW and EI, from 30 minutes | Keys and access agreed at order |
How the fire and forced entry ratings work in Leeds
SR2 means class B3 under LPS 1175, holding a forced entry attempt for three minutes, and the fire rating runs from 30 to 120 minutes, with E, EW and EI named for each opening. One doorset carries both ratings, so leaf, frame, seals and hardware go through one test set, and a door that passes one test but not the other is not a dual certified doorset. The fire ratings page pairs each rating with its test, and the dual certification of fire and security doors guide shows how one doorset holds both ratings. Where a higher forced entry class is needed, the SR3 fire doors range carries the next class up.
The specification observes LPS 1175 Issue 8.2 (September 2024) requiring the SR2 class for each doorset on a compartment line, so the forced entry class sits beside the fire rating on the same sheet. The fire schedule directs BS EN 1634-1:2014+A1:2018 measuring the fire resistance of each doorset, with E, EW and EI named for each opening. The LPS 1175 page runs through the forced entry classes in full, with SR1 holding one minute and SR4 holding ten minutes, and the ten steps that specify an LPS 1175 door guide walks through the order in which each point is agreed.
Opening force matters on a door that patients, students and visitors push open all day. BS 8300 and Approved Document M cap the opening force in the first 30 degrees at below 30 N, and below 22.5 N after that, with the closer set to meet the limit and still close the leaf firm. The fire door closers guide explains how the closer is set, and the fire rated glazed doors page shows the vision panel range for corridor doors.
From survey to fitted door in Leeds
At the first visit, the wall build and the compartment lines are noted, each opening is measured, and the access times for the measure are agreed. After the visit, the specification names the fire rating for each doorset, the SR class, the hardware and the finish, and it is set down so the fitter prices the job from the sheet alone.
Each doorset is fitted, then checked against the written specification at handover, leaf, frame, seal and closer in turn. The fire door inspection checklist guide covers the handover checks for a fitted doorset, and the fire door certification guide explains the papers that travel with the door.
Send the door schedule to our Leeds annexe Saffron Road, Romford, Essex RM5 3ES. Share with us the leaf sizes and the compartment lines your doors must hold. Email [email protected] for plans showing the compartment lines and the door positions. We send the rating, the specification and the price back to you within one working day.
Notes for Leeds buyers
One doorset, two tests. A fire door that passes its fire test but fails its forced entry test leaves the compartment line open to attack, while a doorset that passes both keeps the line true on both counts.
Questions about SR2 fire doors in Leeds
What does SR2 mean?
SR2 is class B3 to LPS 1175. It holds off a forced entry attempt for three minutes, with the class named in the specification beside the fire rating, so the buyer sees both ratings for each doorset on the same sheet.
Which fire rating does an SR2 door carry?
It turns on the compartment line the door sits on. E, EW and EI are named for each opening, with the rating running from 30 to 120 minutes, and the rating is fixed with the buyer at survey stage.
Can one door hold both ratings?
Yes. One doorset is tested for fire and for forced entry together, leaf, frame, seals and hardware in one test set, so both ratings travel on the same doorset.
How long does a Leeds SR2 door job take?
The time depends on the number of doorsets and the lead time on the hardware. A short run usually takes a matter of weeks, while a long run needs more time, with the programme agreed in writing when the survey is done.
Other areas
SR2 fire doors in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.