Fire · EI 30 to EI 120
SR2 Fire Doors in Nottingham
SR2 fire doors in Nottingham for hospitals, universities and the arena: B3 forced-entry grade with a separate fire rating, surveyed and fitted to order.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Nottingham
Get a free quote in Nottingham
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Nottingham
What we supply in Nottingham
A Nottingham building that needs one door to stop both fire and forced entry starts with two ratings, not one. The SR2 grade gives the door a B3 forced-entry rating, with an attack time of three minutes. The fire rating sits apart from that grade, and it is read from BS EN 1634-1, where the classes run E, EW and EI and the times span half an hour to two hours. SR2 fire doors in Nottingham are specified with both ratings named on the same order, so one order names both ratings.
Queen’s Medical Centre takes SR2 fire doors on ward corridors, store rooms and plant areas, where staff move beds and trolleys through the leaf all day and the door must shut firm behind them. Nottingham Trent University takes the same doors on lecture blocks, libraries and halls, and the University of Nottingham takes them on the same kinds of rooms, where students pass through at changeover and the leaf takes daily knocks. Motorpoint Arena Nottingham takes them on back-of-house doors and service corridors, where crowds, deliveries and staff share the same routes on event nights.
Victoria Centre and the shops round Old Market Square take SR2 fire doors on stock rooms, service corridors and plant rooms, where the door must stay shut against smoke and hold its grade after years of use. The physical security in Nottingham page looks at the city as a whole, covering doors, shutters, gates and barriers. A door that serves a hospital ward, a lecture hall or a shop stock room is read the same way, from the rating, the hardware and the frame that holds it.
Hospital wards, lecture blocks and arena corridors
A ward corridor door at Queen’s Medical Centre opens for beds, trolleys and staff on foot, and it must close by itself every time. The closer holds the leaf shut against smoke, and the vision panel lets staff see the corridor before they push through. The hospital fire door notes cover ward doors in full, and the fire door closer notes cover the closer grades that keep a leaf shut.
Lecture blocks at the two Nottingham universities take doors that students push open all day, so the hinge set, latch and closer wear faster than the same parts on an office door. Hinges to BS EN 1935 grade 13 are tested at 120 kg for 200,000 cycles, while grade 14 takes a 160 kg leaf over the same 200,000 cycles. Lever handles to BS EN 1906 grade B or B1 suit a leaf that many hands use each day.
Motorpoint Arena Nottingham takes SR2 fire doors on the routes that crowds, staff and deliveries share on event nights, and the leaf must stay clear, shut firm and open fast when the crowd moves. Where more than 60 people gather in one room, the panic bar to BS EN 1125 must span at least 60 per cent of the leaf width and work with one push. The stadium fire door notes cover arena doors in full.
How the SR2 grade and the fire rating sit side by side
The specification cancels LPS 1175 Issue 8.2 (September 2024) cancelling any grade table from an earlier issue that a supplier still sends with a quote. The LPS grade is a forced-entry rating, and the fire rating is separate, so a door that passes one test has not passed the other until both sets of evidence name the door as built. SR2 sits at B3, with three minutes of attack time. SR1 at A1 allows one minute, and the step past SR2 takes the attack time to five minutes at SR3 and ten at SR4.
The fire rating is read from BS EN 1634-1, with the classes and times set out on the fire ratings page. The test evidence names the leaf and the frame, the seals and the hardware together, because a grade claimed for a leaf alone leaves the frame and the ironmongery outside the test. The LPS 1175 page carries the full grade table. The SR2, SR3 and SR4 notes set the three grades side by side.
Gaps round the leaf are checked at 4 mm, and any wider gap lets smoke through before the seals have a chance to work. The intumescent seal swells once the heat passes roughly 200 to 250 degrees, and the swollen seal closes the gap round the leaf. Smoke seals carry the Sa or S200 mark under BS EN 1634-3, and they hold back cold smoke from the first minute. The fire door gaps notes cover the gap check in full, and the intumescent seals notes cover the seal types and the temperatures that set them off.
BS 8300 keeps the opening force low enough for staff pushing a trolley or a person in a wheelchair. Approved Document M sets the same limit in figures, with the force held under 30 N early in the swing and under 22.5 N later on. A closer that pulls too hard fails the access test, and a closer that pulls too soft fails to shut the leaf. The fire door hardware notes cover the latch, the hinges and the closer as one set.
The enhanced tier starts at 800 people in a venue, and the standard tier covers halls that hold from 200 up to 799. The SIA holds the regulator role, Royal Assent dates from 3 April 2025, and the start date is expected in spring 2027. Each tier and its duties are paired on the Martyn’s Law page. PAS 24 is a residential door standard, so it has no place on a commercial door order.
Nottingham buildings and the SR2 door each one takes
| Nottingham building | SR2 door | Building notes |
|---|---|---|
| Queen’s Medical Centre | SR2 fire door with vision panel | Ward corridors, stores and plant areas |
| Nottingham Trent University | SR2 fire door with heavy-duty hinges | Lecture blocks, libraries and halls |
| University of Nottingham | SR2 fire door with panic hardware | Lecture blocks and student halls |
| Motorpoint Arena Nottingham | SR2 fire door with panic bar | Back-of-house doors and service corridors |
| Victoria Centre | SR2 fire door on stock rooms | Service corridors, stock rooms and plant rooms |
Read the rows as a starting point. Each opening takes its door from the daily use and the risk at that spot.
Survey, fitting and handover in Nottingham
The survey starts at each opening, before any door is named. The engineer takes the opening sizes, looks at the wall and the lintel, checks the frame and the floor, and weighs the risk at the front of the building against the risk at the back. The survey sets the door type, the grade, the hardware and the finish, and the design in Nottingham notes turn that survey into a specification.
A Nottingham door rarely stands alone on its building. The steel doors beside it are covered on the fire-rated steel doors in Nottingham page, the security doors at the front are covered on the security doors in Nottingham page, and the blast doors on the same site are covered on the blast-resistant doors in Nottingham page.
The door schedule and the grade evidence are held at the card Saffron Road, Romford, Essex RM5 3ES. The Nottingham file travels with the team to the survey. Phone promptly with the opening sizes and the fire rating, so those details set the survey price.
Email [email protected] with preparation notes for the Nottingham survey, and the reply covers the survey scope and the fee. Fitting is covered on the installation in Nottingham page, and the doors are made to order, as covered on the manufacture in Nottingham page.
A grade on a leaf alone proves little, so read the evidence for the door as built, frame, seals and hardware included.
Nottingham buyers ask about SR2 fire doors
What does SR2 mean on a Nottingham fire door?
SR2 is the B3 grade under LPS 1175, with an attack time of three minutes. It is a forced-entry rating, and the fire rating is separate, read from BS EN 1634-1, where the E, EW and EI classes apply.
How wide should the gap round a Nottingham SR2 fire door leaf be?
The gap is checked at 4 mm round the leaf. A gap past that lets smoke through before the intumescent seal swells, so the gap is measured again at handover.
Which closer suits a Nottingham SR2 fire door in a hospital corridor?
A closer of at least EN 3 suits a fire door leaf, set so the leaf shuts firm without pulling too hard for staff with a trolley. BS 8300 sets the opening force limits, and the closer must meet them while still shutting the leaf.
Does a Nottingham arena need an SR2 fire door or a higher grade?
The risk at the opening sets the grade, not the building size. An arena back-of-house door that holds stock overnight may take a higher grade than a front door in daily use.
Plan the SR2 fire doors for your Nottingham building
Send the opening sizes and the fire rating, and the price covers the survey, the doors and the file. Get a free quote