Fire · EI 30 to EI 120

SR2 fire doors in Milton Keynes

SR2 fire doors in Milton Keynes, for the hospital, Stadium MK and the university, with a B3 rating, a fire class and a one working day reply.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Milton Keynes
Prefer to talk?+44 7352 267239

Get a free quote in Milton Keynes

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Milton Keynes

What we supply in Milton Keynes

More on this

One leaf in Milton Keynes carries two ratings at once: forced entry against the B3 tool set, and a fire class for the minutes the building needs. The leaf is built for the exact opening it guards, and a single written record names both ratings, the hardware and the finish before any steel is cut. A hospital corridor, a plant room at the university and an office at the stadium each ask something different of a doorway, so the brief starts with the risk at that spot and then moves to leaf, frame and wall round the opening.

Health, teaching and public buildings across Milton Keynes put this work through its widest mix. Corridors and plant rooms at Milton Keynes University Hospital stay busy through long days, lecture rooms, laboratories and plant areas at the Open University sit behind doors in heavy daily service, and concourses, offices and hospitality rooms at Stadium MK sit behind leaves that face crowds on match days. Centre:MK and Xscape put public entrances before shoppers and visitors, museum rooms at Bletchley Park keep their own entry rules, and offices in Kingston and Furzton hold plant rooms beside entrances staff pass through all day. For openings beyond fire doors, the physical security in Milton Keynes page covers the rest, yet each SR2 order still starts with its own building.

The class for each door follows the risk assessment for the spot, not the leaf size. The survey measures the breadth and the drop of each opening, looks at the make-up of the wall round it, and notes lintel, sill and any services crossing the reveal, so the specification after it names the rating, the fire class and the hardware for every numbered opening.

Fire classE, EW or EI, set per door from the fire strategy
SR2 ratingB3 tool set, held for 3 minutes
Survey firstEvery opening measured at the building
One documentRating, fire class, hardware and finish for each door

Where SR2 fire doors go in Milton Keynes

A corridor leaf at the hospital faces the hardest test in the city. At Milton Keynes University Hospital the leaf must shut firmly on every swing, with smoke seals fitted and a closer sized to the leaf weight. A plant room leaf carries the same fire class, and its lock is one staff can release fast from inside. Leaves that carry both ratings are covered by the dual certification guide. The keeping dual certified doors valid page explains how the rating stays good once the door is in use, so the leaf and its paperwork never drift apart.

Teaching and public buildings need the same care in another form. The Open University holds lecture rooms, laboratories and stores spread across a broad estate, with rooms of the same kind beside entrances that students and visitors pass through all day. Stadium MK, Centre:MK and Xscape each hold public rooms with a leaf facing a queue, and Bletchley Park puts leaves beside its ticket and information points. The access guide sets out what BS 8300 and Approved Document M allow: a push under 30 newtons through the first 30 degrees of swing, with under 22.5 newtons beyond that point, so a leaf that resists attack still opens for everyone who needs it.

How the SR2 rating and the fire class are chosen

Which class applies follows the risk assessment for the spot, not the size of the leaf. The schedule restates LPS 1175 Issue 8.2 (September 2024) assigning the class the opening needs, so the SR2 class sits beside the fire class in one document. SR2 means the B3 tool set held for 3 minutes, against the 1 minute of SR1 at A1, the 5 minutes of SR3 at C5 and the 10 minutes of SR4 at D10, and the SR2, SR3 and SR4 compared page puts the four classes beside each other.

The test record demonstrates BS EN 1634-1:2014+A1:2018 covering the fire class and the leaf together. The classes run E, EW and EI, in steps of 30 minutes up to 120, and the fire strategy for the position settles which class each door needs. The classes behind the test are listed on the fire ratings page, while the 10 steps guide walks a buyer through the specification, starting with the risk at the opening and ending with the hardware on the leaf.

How the rated leaf performs comes down to the frame round it. The frame is steel, matched to the leaf, and the hinges carry the leaf weight without dropping, while fixings anchor the frame to the wall. A blow on the leaf then meets the frame as well as the leaf. Intumescent seals sit round the leaf edge, the closer is sized to the leaf weight. The how to specify guide runs through the checks, as does the specification mistakes guide, before the order goes in.

Hardware numbers go on the specification with the ratings. The closer meets BS EN 1154 at a minimum of EN 3 on a fire door, the hinges meet BS EN 1935 at grade 13 for 200,000 cycles and 120 kg or grade 14 for 200,000 cycles and 160 kg, and the intumescent seals expand near 200 to 250 degrees to close the gap round the leaf. The gap round a fire door leaf is 4 mm, and the fire door closers, fire door hardware, intumescent seals and fire door gaps pages each cover one of those items in full.

Specification item What it records
Leaf with frame Steel leaf with its frame built for the opening
Forced entry rating SR2, B3 tool set, 3 minutes
Fire class E, EW or EI, in steps of 30 minutes to 120
Hardware Hinges, closer and lock sized to the leaf
Seals Smoke and intumescent seals fitted round the leaf
Finish Powder coat shade to suit the room and the frontage

From survey to fitting

Every Milton Keynes SR2 job begins at the opening itself. The survey measures breadth and drop at three points, looks at the make-up of the wall round the opening, and notes lintel, sill and any services crossing the reveal. A written reply then names the rating and the price for each opening, and it comes back inside one working day, so dates for the workshop and the fitting can be set before manufacture begins. The lead times guide sets out each step from survey to fitting. The rating upkeep guide covers the checks to run once the door is in use.

The workshop works from the paperwork agreed at survey stage, and the fitting crew works from the site measurements. On site, the frame is set level and square, with the leaf hung on hinges that carry its weight, the seals set round the leaf edge, and the closer tuned so the leaf shuts firmly without a slam. Our plant Saffron Road, Romford, Essex RM5 3ES from there each leaf is built to its written specification. The fire rated steel doors range is listed on its own page.

Wedging a fire door open, or fitting the wrong closer, takes away the rating the test sheet promises. The specification lists leaf, frame, seals and closer together, so no buyer is left holding test evidence for a door the fitting has let down.

Questions about SR2 fire doors in Milton Keynes

What does the SR2 class mean on a fire door?

The SR2 class comes from LPS 1175 and names the B3 tool set held for 3 minutes, and it stands beside the fire class rather than taking its place. A leaf with both ratings has passed an attack test and a fire test, and the written specification lists both ratings for each door, so the door ordered is the door fitted.

Can an SR2 fire door be used every day?

Yes, when the door is specified for daily use. The push is limited by BS 8300 and Approved Document M to under 30 newtons over the first 30 degrees of swing, with under 22.5 newtons past that point, so the leaf closes firmly yet opens for everyone. The closer is set to the leaf weight and how busy the opening is, and a door that slams or drags is checked before the seals and hinges wear.

Does PAS 24 apply to a commercial SR2 door?

No. PAS 24 is a residential standard for doors and windows in new homes, so it never settles the rating for a commercial door. A commercial SR2 door is specified against the forced entry rating and the fire class, and the LPS 1175 versus PAS 24 page sets out how the two standards differ.

How long does a Milton Keynes SR2 order take?

The written reply fixes the timing once the survey notes have been read. The work then runs survey, paperwork, workshop and fitting in turn, and the reply puts a date on every stage, so the team can plan around rooms that must close.

Send the measurements of every opening, with the fire class beside each door, to [email protected] from the first visit, and the reply, which follows inside one working day, sets out the rating for every door, and the price sits beside it.

Get a free quote