Certified physical security

ArxBridge
Installer checking the seal of navy steel fire-rated doors in a UK office corridor

Fire · EI 30 to EI 120

SR2 fire doors in Portsmouth

SR2 fire doors for Portsmouth port, dockyard, hospital and campus, EI ratings to 120 minutes with B3 forced entry on the same leaf for every corridor.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Portsmouth
Prefer to talk?+44 7352 267239

Get a free quote in Portsmouth

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Portsmouth

What we supply in Portsmouth

More on this

An SR2 fire door in Portsmouth is ordered as one doorset, with the fire rating, the forced entry grade and the ironmongery all proved together rather than bought as separate parts.

SR2 fire doors guard stair cores, ward corridors, port offices and campus blocks across Portsmouth, holding fire back for their rated minutes while resisting a forced entry attempt at the same leaf.

Portsmouth sets fire doors beside the sea and beside crowds, from Portsmouth International Port and the Historic Dockyard to the University of Portsmouth, Queen Alexandra Hospital at Cosham and the shops at Gunwharf Quays, so each leaf takes a rating matched to its corridor, its use and the people behind it.

Two leaves of equal size often hold different ratings, so the rating on the schedule fixes the order, with frame, seals and ironmongery priced inside the same doorset rather than added as extras later.

Fire classesE, EW, EI, up to 120 minutes
Forced entrySR2 with B3 at three minutes
Dual ratingFire and forced entry on one leaf
Places coveredPort, dockyard, hospital, campus

Where Portsmouth puts SR2 fire doors

Portsmouth International Port orders fire doors for its ferry terminal corridors and port offices, where travellers and staff move through the same routes at every sailing, and the leaf there must hold fire back while staying easy to open on an escape route.

The Historic Dockyard orders leaves for store rooms, workshops and gatehouse offices, where kit and visitors pass through the same doors all day, and the leaf must keep its rating while taking daily knocks from trolleys and kit.

Queen Alexandra Hospital at Cosham orders leaves for ward corridors and treatment rooms where beds, trolleys and staff move all day, and the University of Portsmouth orders leaves for stair cores and lecture blocks where students gather between classes.

The healthcare sector page looks at hospital corridors, and the education sector page looks at campus stair cores.

Gunwharf Quays orders leaves for shop stockrooms, restaurant kitchens and service corridors behind the quayside fronts, and Fratton Park orders leaves for concourses and hospitality rooms that fill on match days.

For the wider city view, the physical security in Portsmouth page runs from the port to the hospital and the campus.

Spinnaker Tower orders leaves for its ticket desks, offices and service rooms at the base, where visitors queue through the year and the leaf must hold its rating while staying open to the public.

E, EW and EI ratings from 30 to 120 minutes

Fire ratings sort leaves by what they hold back: E holds integrity, EW holds integrity with reduced radiation, and EI holds integrity with insulation, and each letter is paired with minutes, from 30 through 60 and 90 to 120.

The furnace test proves BS EN 1634-1:2014+A1:2018 proving the leaf, frame and seals as one doorset, and the rating on the certificate names the minutes the set held.

A corridor leaf takes a different rating than a store leaf, and the fire strategy fixes the rating for that corridor, so the schedule names the rating, the leaf and the reason in one line.

Corridor Use in Portsmouth Fire rating Forced entry
Port office corridor Offices beside the ferry terminal EI60 SR2 with B3
Hospital ward corridor Wards at Queen Alexandra Hospital EI60 SR2 with B3
University stair core Stair core in a lecture block EI30 SR2 with B3
Dockyard store door Stores in the Historic Dockyard EI90 SR2 with B3

Every fire class sits on the fire ratings page; the fire door certification guide reads what a certificate must show before a leaf is accepted.

A leaf that holds fire for sixty minutes still needs its seals, closer and hinges checked as part of the same rating, since a gap at the edge takes the minutes away.

Port buildings take their rules from the fire door rules for ports guide, which reads the regulations for quayside buildings in one place.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

One leaf, two ratings: fire and forced entry

A dual rated leaf carries a fire rating and an SR2 grade on the same certificate, so one leaf answers both the fire strategy and the security brief for its corridor, with no second leaf needed at the same opening.

The forced entry side of the same leaf guards LPS 1175 Issue 8.2 (September 2024) guarding the three minute B3 grade beside the fire rating.

The scale runs SR1 with A1 at one minute, SR2 with B3 at three minutes, SR3 with C5 at five minutes and SR4 with D10 at ten minutes, so the forced entry minutes are read beside the fire minutes on one line.

The dual certification guide reads fire and security ratings together, and the keeping a dual rating valid guide lists the checks that keep both ratings live.

The SR2, SR3 and SR4 guide runs the three higher grades against each other, and every grade in the set appears on the LPS 1175 page.

How leaf, frame and seals are chosen together

The corridor and its escape route fix the brief: leaf width and height, the beds and trolleys that pass, and the sight lines staff need, with the rating settled for that leaf before any price is set.

A heavy leaf calls for a frame, hinges and closer built for its weight, and a corridor leaf that swings all day calls for seals that stay tight through the working year, so the set is priced as one doorset, since a light frame under a strong leaf carries no proved rating.

Seals first: a ward leaf needs seals that close the gap at every edge. The closer next: a stair core leaf needs a closer that pulls the leaf shut each time. The threshold last: a port office leaf needs a threshold that lets trolleys roll over it.

Name the fire rating, the forced entry grade and the ironmongery set on one schedule line, so a leaf never arrives with a strong rating and a closer that takes it away.

Where a ward leaf needs its own rules, the fire door rules for hospitals guide reads the regulations for hospital corridors in one place.

Survey, fitting and care after handover

Before any leaf is ordered, the opening is measured, the wall build is noted and the corridor is watched in use through the day, and the rating, size and ironmongery go down on one sheet together.

Work begins with the frame, set level and bolted to the wall itself, and the leaf is hung after it, with seals, closer and fixings checked singly before the door is shut.

Once handed over, the leaf gets a look for gaps at the edges, the seals get a check for wear, and a closer that stops shutting the leaf on its own is re-set, with any leaf that no longer shuts taken out of service until it is put right.

Sample leaves and ironmongery sets are on view at our Portsmouth cupola Saffron Road, Romford, Essex RM5 3ES. Call them ahead of a visit so the right samples are out on the table.

Email [email protected] in advance of the survey with the corridor sizes and the rating each leaf needs, and answers come back within one working day.

Before any leaf is ordered the sizes are confirmed in writing, so the rating on the schedule is the rating that arrives.

Frequently asked questions

What fire rating fits a ward corridor at Queen Alexandra Hospital?

A ward corridor leaf is often ordered to EI60 with an SR2 grade, and the fire strategy for that corridor fixes the rating.

Can one leaf carry a fire rating and SR2 together?

It can. A dual rated leaf carries a fire rating and an SR2 grade on the same certificate, so one leaf answers both the fire strategy and the security brief for its corridor.

Can an SR2 fire door be trimmed to fit an old frame?

No. The leaf, frame and seals are proved as one doorset, so a trim after making would open a gap and take the rating away. The opening is sized first and the leaf is built to that size.

How is a damaged SR2 fire door replaced?

The damaged leaf is lifted out whole and a fresh leaf is made to the same size and rating, with seals, closer and hinges looked over before the fresh leaf is hung. A leaf that no longer shuts stays out of service until the fresh leaf is in.

Send the corridor sizes and the rating for each leaf, and the team will price leaf, frame and ironmongery as one package. Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.