Fire · EI 30 to EI 120

SR2 fire doors in London

SR2 fire doors for London housing blocks, hospitals and hotels, fire rated and forced entry tested, with a written specification and price range.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in London
Prefer to talk?+44 7352 267239

Get a free quote in London

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in London

What we supply in London

More on this

An SR2 fire door in London holds two lines at once: it holds fire and smoke back for the time written on its rating, and it holds a forced entry attempt for three minutes. The door is tested as a set, naming leaf, frame, seals and hardware together, so a housing block, a hospital or a hotel can trust the door on the stair and the door on the ward alike. London buyers order SR2 fire doors where a fire door must also resist attack, or where a security door must also hold fire.

The housing blocks of Tower Hamlets, Southwark and Camden need SR2 fire doors for flat entrances and stair doors that face the public parts of the building, the hospitals at Guy’s, St Thomas’ and the Royal London need them for ward doors and pharmacy stores that stay open through the night, and the West End hotels need them for service doors and plant rooms that sit behind the guest floors. The schools of inner London need them for hall doors and store rooms, the care homes of the suburbs need them for bedroom corridors and lounge doors, and King’s College London and University College London need them for laboratories and stores that hold equipment and chemicals. Student accommodation in the centre needs them for flat doors that face shared corridors, and the offices of the City need them for plant rooms and risers that sit beside the working floors.

ArxBridge supplies SR2 fire doors for London housing blocks, hospitals and hotels, with each opening measured on site and each door proved to the ratings on the order. Before manufacture, the buyer agrees the hardware, the forced entry class and the fire rating. London as a whole is covered on the physical security in London page. The next class up is on the SR3 fire doors page.

Fire ratingE, EW and EI, 30 minutes through to two hours
Forced entrySR2, class B3, three minutes
Test methodBS EN 1634-1:2014+A1:2018
Survey firstOpenings measured on site before pricing

London buildings that need an SR2 fire door

Housing blocks make the clearest case, in Tower Hamlets, Southwark and Camden. The flat entrance door faces a corridor that anyone can reach, the stair door faces the escape route itself, and both must hold fire back while also resisting a lever attack at the lock. A steel doorset suits a flat entrance that takes daily use, while a timber faced set suits a corridor where how the door looks matters. The SR2, SR3 and SR4 compared guide explains where each class fits.

Hospitals and hotels make the second case, at Guy’s, St Thomas’ and the Royal London, and across the West End. The ward door must hold fire while staff move patients through it, the pharmacy store must resist attack while holding medicines, and the hotel service door must hold both lines while porters pass through all day. A door with a vision panel suits a ward where staff need to see through, while a solid door suits a store where nobody needs a view. See how dual certification works for the way one door carries both ratings.

Schools, care homes and universities make the third case. Rooms that hold people sit beside rooms that hold risk in each one, each one needs doors that hold fire on the escape route and resist attack at the store, and each one needs the hardware to work for staff who use the door a hundred times a day. For the evidence a buyer should ask for, see the fire door certification guide, while the E, EW and EI ratings are listed on the fire ratings page.

What a London SR2 fire door usually needs

Each row pairs a London door with the risks it faces and the fitting it usually takes.

Door in London Risks it faces Rating and build Extra help
Housing block flat entrance Fire and forced entry EI 60, SR2, steel doorset Self closer and smoke seals
Hospital ward door Fire and forced entry EI 60, SR2, vision panel Hold open device
West End hotel service door Fire and forced entry EI 30, SR2, steel doorset Access control reader
School hall door Fire and forced entry EI 30, SR2, timber faced Panic hardware
University laboratory door Fire and forced entry EI 60, SR2, steel doorset Keyed lock and closer
Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

How the two ratings are chosen in London

The fire rating comes first, from the fire strategy of the building. A flat entrance often takes EI 60, a corridor door often takes EI 30, and a plant room often takes a higher rating, with E, EW and EI covering integrity, radiation and insulation for 30 minutes to two hours. The forced entry class follows from the risk at the door: SR2 sits at class B3 and holds for three minutes, with SR1 at class A1 for one minute, SR3 at class C5 for five minutes and SR4 at class D10 for ten minutes.

The specification recaps LPS 1175 Issue 8.2 (September 2024) publishing the forced entry class for each door, so the SR2 class stands next to the fire rating on the same line. The fire test record foreshadows BS EN 1634-1:2014+A1:2018 dating of the fire test for each doorset, so the E, EW and EI ratings sit beside the SR class on the same line. On the LPS 1175 page you will find SR1 to SR4 listed in order, together with the tools each class is tested with.

A door that resists forced entry still needs to open for escape. Under BS 8300 and Approved Document M, a wheelchair user must still open the door with ease. The limit is at most 30 N for the first part of the swing, up to 30 degrees, and at most 22.5 N once the door has swung further. The evidence must cover the whole set, not the leaf on its own, so the seals, the closer and the hardware are named alongside leaf and frame.

From survey to fitted door in London

At the first visit each opening is measured by hand: the reveal depth and the wall build are noted, the cill line is recorded too, and the room use is checked. The specification that follows lists the fire rating first, then the SR class, leaf material, hardware and finish. From that list, a contractor works out a firm price with no guesswork left in it.

The doorset is made in the workshop and hung on site. Before handover, the finished door goes through a check against its written specification. The gaps are measured, the closer is set, the seals are checked and the handover file is handed to the facilities team.

Send the door sizes to our London mezzanine, Saffron Road in Romford, Essex RM5 3ES. Write to us with the door sizes and the ratings you need straight away, and the survey team will bring along the hardware samples that suit the door. Email [email protected] and state the door sizes, the fire rating and the SR class you need, and a written reply lands inside one working day with the ratings and the price.

Notes for London buyers

Ask for both ratings on one certificate, not two. A door with a fire certificate and a separate security certificate still needs the two to name the same doorset, or the evidence splits at the first audit.

Questions about SR2 fire doors in London

Can one door carry both ratings?

Yes. One set of evidence covers both the fire rating and the forced entry class on a dual certified door, and leaf, frame, seals and hardware are tested together as a single set. The specification names both ratings on the same line.

Does an SR2 fire door need a closer?

Yes, where the door sits on an escape route or a fire compartment line. The closer keeps the door shut, and the seals keep the smoke back, so the fire rating holds when the door is not in use.

Can a timber door be SR2?

Yes, where the timber leaf is built and tested to the class. A steel doorset is the common choice for a flat entrance, while a timber faced set suits a corridor where the look of the door matters, and both carry the same SR2 evidence.

How long does a London SR2 door order take?

The time turns on how many doors there are and the ratings ordered, since each door is made to its opening. The survey sets out the dates in writing for the buyer, so you can plan the work.

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.