Certified physical security

ArxBridge
Waterfront offices with glass entrances and bollards in Cardiff

Fire · EI 30 to EI 120

SR2 fire doors in Cardiff

SR2 fire doors in Cardiff for hospitals, universities, offices and civic buildings, with fire classes, SR2 resistance and fitting set out for each opening.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Cardiff
Prefer to talk?+44 7352 267239

Get a free quote in Cardiff

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Cardiff

What we supply in Cardiff

More on this

An SR2 fire doors order for Cardiff pairs a fire rated leaf with forced entry resistance, so one doorset holds back fire and smoke for its rated time and holds back a hand tool attack for 3 minutes with tool set B3. The leaf, frame, hinges, lock and closer are tested as one doorset, and the rating only stands when the item on site matches the item that was tested, down to the hardware positions and the gaps round the leaf. A fire rated steel door in Cardiff covers the fire side alone, while this page covers the doorset that carries both ratings at once.

Cardiff gives that doorset a wide range of buildings. The University Hospital of Wales and the hospitals round Heath hold corridors and ward doors that stay shut against fire and open easily for trolleys, Cardiff University and its halls hold doors across teaching rooms and laboratories, and the civic buildings round City Hall and the National Museum Cardiff hold doors that meet the public every day. Cardiff Bay holds offices beside the water, the Principality Stadium and the Wales Millennium Centre hold service doors behind busy public rooms, Queen Street and St David’s have shopfront doors in constant use, and Cardiff Central station and Cardiff Airport hold doors at entrances that never fully close. Physical security in Cardiff gives the broader picture across the city, and an SR2 fire doorset follows the opening, not the postcode.

SR2 rated3 minutes against tool set B3, leaf, frame and lock judged together
Fire ratedFire classes E, EW and EI, from 30 up to 120 minutes
Made to sizeEvery doorset made for the opening sizes taken on site
Written recordRating, hardware and gaps listed for each opening before fitting

What SR2 means on a Cardiff doorset

The test record endorses LPS 1175 Issue 8.2 (September 2024) providing a table where SR2 sits at three minutes under tool set B3, between SR1 at one minute under A1 and SR3 at five minutes under C5, with SR4 at ten minutes under D10. Each part of the doorset earns its own verdict against the rating written on the order: a heavy leaf set in a light frame fails, and a sound lock fitted to a frame that bends under load fails too. The LPS 1175 page lists every rating in the scale, and the figure written on the order is the figure the fitted doorset has to meet on site.

The fire side of the doorset is tested separately, and the test record accepts BS EN 1634-1:2014+A1:2018 grouping the fire classes by what they hold back: E for flames alone, EW for flames with limited radiation, and EI for flames plus insulation against heat, over periods of 30 to 120 minutes. A doorset that carries E30 holds back flames for 30 minutes, while a doorset that carries EI60 holds back flames and heat for 60 minutes, and the class named in the specification is the class the fire strategy for the building asks for. The fire ratings page gives the classes in full, and the how to specify security doors walkthrough lists the checks a drawing has to clear before the order is placed.

How the fire rating and the SR2 rating sit together

A doorset that carries both ratings has been tested for both jobs, and the hardware that serves one job must not undo the other. A closer that holds the leaf shut for fire must still let the leaf latch firmly for security, and a lock that resists a tool attack must still let the leaf release cleanly on the fire alarm. The dual certification walkthrough shows how the two tests sit together, and the keeping a dual certified doorset valid guide shows why a later change to the hardware can take the rating away.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Where Cardiff buildings use this doorset

Hospital corridors round Heath ask for this doorset where a ward door must hold back fire and also keep store rooms and medicine rooms shut against entry. University halls and laboratories ask for it where a door must hold a fire line and also guard equipment rooms that sit empty at night. Offices in Cardiff Bay ask for it at stair doors and riser cupboards, where a fire line runs past rooms that hold plant and records, and the doorset keeps the line intact while the rooms stay locked.

Older civic fabric asks for a slower approach. City Hall, the National Museum Cardiff and the buildings round Cardiff Castle hold doors in openings that are not square and walls that are not plumb, so the frame is measured in three places and the leaf is made to the smallest reading. The listed building fire doors walkthrough deals with the case where the opening must be kept and the doorset must fit it, and the finish is agreed before the build so the new leaf sits quietly beside the old stone and timber.

Specifying, fitting and keeping the rating valid

The order starts with the opening list, and each line records the opening dimensions, the wall build-up, the fire class, the SR rating and the hardware. On site, the surveyor takes the width and the height at three separate points, records the sill height and any pipes or cables that run through the opening, so the drawing works from the smallest reading and the leaf that arrives suits the opening it was taken for. The ten-step LPS 1175 specification walkthrough follows the same list in order.

After fitting, the rating is kept by checking the closer, the seals and the gaps at regular intervals and by writing down what was found. A gap that has grown, a seal that has split or a closer that no longer shuts the leaf all take the doorset away from the item that was tested, and each fault is dealt with before the next scheduled visit. The Romford workshop: Saffron Road, Romford, Essex RM5 3ES. Visit the office during working hours.

Opening Fire class SR rating Check on site
Ward corridor EI60 SR2 Gaps, seals and closer
Plant room E30 SR2 Lock, hinges and latch
Office stair EI30 SR2 Latch, seals and closer
Store room EI60 SR2 Lock, gaps and frame fixings

A doorset stands or falls on its frame. If the leaf hangs square while the frame sits twisted, the latch catches and the seals leave gaps, so the frame is checked true before the leaf goes on, and the gaps are measured once more once the finish has dried.

Questions about SR2 fire doors in Cardiff

Can a single doorset hold a fire rating and SR2 together?

Yes, where one doorset has passed both tests as one item, with the leaf, frame, hinges, lock and closer all in place at the test. The order names both the fire class and the SR rating, and the item that arrives on site must match the tested item, so a later swap of the lock or the closer can take one or both ratings away.

What fire class should a Cardiff hospital corridor doorset carry?

The fire strategy for the building names the class, and the doorset is ordered to that class, whether the line asks for E30, EI30 or EI60. The class is written on the opening list beside the SR rating, so the leaf, the seals and the closer are all chosen for the same line, and the handover sheet records the class that was fitted at each opening.

Do older Cardiff buildings need a different approach?

Yes, when an opening sits out of square or a wall runs out of plumb, the frame is measured in three places and the leaf is made to the smallest reading. The finish and the hardware are agreed before the build, so the new doorset fits the old opening without cutting the wall, and the listed building guide covers the case where the opening itself must be kept.

How often should the doorset be checked after fitting?

The latch, the closer, the seals and the gaps are checked at regular intervals, and what was found is written down for each opening. A gap that has grown, a seal that has split or a closer that no longer shuts the leaf is dealt with ahead of the following check, so the doorset stays close to the item that was tested.

Send the opening sizes with the fire class and SR rating for each doorset to [email protected] when the opening list is ready, and the reply that arrives inside one working day gives the specification, the hardware and the price for each doorset.

Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.