Certified physical security

ArxBridge
Quayside offices and navy steel entrance door beside the Tyne in Newcastle upon Tyne

Fire · EI 30 to EI 120

SR2 Fire Doors in Newcastle upon Tyne

SR2 fire doors in Newcastle upon Tyne for shops, offices, stadiums and hospitals. Forced entry rated to LPS 1175 SR2 with a fire rating beside it.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Newcastle upon Tyne
Prefer to talk?+44 7352 267239

Get a free quote in Newcastle upon Tyne

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Newcastle upon Tyne

What we supply in Newcastle upon Tyne

More on this

An SR2 fire door does two jobs in one doorset: it holds back fire, and it resists a forced entry attack. SR2 sits at class B3 in LPS 1175 Issue 8.2, the September 2024 issue, and the three minute attack it must resist uses the tool set named for class B3. Leaf, frame, hinges, lock and wall fixing are tested together as one doorset, so strength in the leaf alone buys nothing. SR2 fire doors suit the Newcastle upon Tyne openings where a fire line and a security line fall on the same door.

Newcastle upon Tyne hands these doors a clear set of sites. Grainger Town and Eldon Square hold shops and offices that lock stock and equipment behind a front door. The Quayside holds restaurants and offices along the river. St James’ Park holds concourses and service areas that empty out after a match. Newcastle University and Northumbria University hold teaching and research buildings, and the Royal Victoria Infirmary and Freeman Hospital hold wards and plant buildings. Every one of those doors must hold a fire rating and resist a forced entry attempt after hours.

What follows covers the Newcastle upon Tyne openings that need an SR2 fire door, the two ratings side by side, the specification for a shop, a stadium or a hospital, and the steps from first measure to handover. The Newcastle upon Tyne area page gives the wider rated protection across the city.

RatingSR2, LPS 1175 Issue 8.2, class B3
Fire ratingE, EW or EI, 30, 60, 90 or 120 minutes
Attack timeThree minutes, tool set B
Reply timeNext working day

Newcastle upon Tyne openings that need an SR2 fire door

The heaviest demand sits in Grainger Town and around Eldon Square. A shop front guards stock, an office entrance guards equipment and records, and a service door off a rear lane faces the same risk after closing time, while the fire line through the same opening must stay intact. Three minutes of resistance covers the tool set a casual intruder carries, so SR2 fits many of these openings, though the class should follow the risk at that opening rather than the street name.

Stadium and Quayside venues make the second set. Concourse doors, hospitality entrances and service doors at St James’ Park, and restaurant and office doors along the Quayside, need a fire rating for crowded areas and a forced entry rating for the hours the building stands empty. Hospital and university doors make the remaining set: ward doors, plant rooms and stores at the Royal Victoria Infirmary and Freeman Hospital, and laboratories and plant areas at Newcastle University and Northumbria University, where a doorset must hold fire back and keep unauthorised entry out of rooms holding drugs, records or research material.

Reading the SR2 rating beside the fire rating

SR2 means the doorset stood up to a defined three minute attack, using the tool set named for that class, and the test covers leaf, frame, hinges, lock and the fixing into the wall. The SR scale itself comes from LPS 1175 Issue 8.2. The LPS 1175 classes page lists each class in turn. Fire resistance comes in classes E, EW or EI, from 30 minutes up to two hours, under the furnace test BS EN 1634-1:2014+A1:2018, which grades the doorset, and the fire ratings page walks through the classes. A doorset claiming both ratings must hold test papers for each, and the specification should name both in full.

Newcastle upon Tyne opening Door duty Rating to quote Fire rating
Shop or office, Grainger Town or Eldon Square Front and rear entrance, fire rated SR2, tool set B, three minutes E, EW or EI, 30 to 60 minutes
Stadium or Quayside venue Concourse and service door SR2, tool set B, three minutes E, EW or EI, up to an hour
Hospital ward or store, RVI or Freeman Ward, store and plant room door SR2, tool set B, three minutes E, EW or EI, 30, 60, 90 or 120 minutes
University laboratory or plant area Door on a fire compartment line SR2, tool set B, three minutes EI 30, EI 60 or EI 120

An opening whose risk runs past SR2 needs the next class quoted, not SR2 stretched past its test. The guide to SR2, SR3 and SR4 compares the classes and the point where a higher class earns its extra cost, and the SR3 fire doors range covers those openings. Both ratings need looking after once the door is in use, and the guide to keeping dual certified fire security doors valid names the checks worth making after fitting.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Putting an SR2 specification together in Newcastle upon Tyne

Begin with four items: opening size, SR2 class, fire class and hardware. The opening size decides the leaf and frame. SR2 decides lock, hinges and wall fixing. The fire class decides leaf build and seals. Hardware decides closer, panic bar and access control. A door needing all four should list all four together in the specification, each beside its own test papers. The guide to SR2, SR3 and SR4 lays out the differences and the point where a higher class earns its extra cost.

List leaf, frame, seals, closer, lock and fixing method as one set, so both ratings rest on the same doorset as built. The fire door hardware guide deals with closers, locks and panic bars on a rated door, and the fire door certification guide spells out the papers to ask for before the order goes in.

From first measure to a fitted SR2 door in Newcastle upon Tyne

A Newcastle upon Tyne job usually starts from drawings, or from a site plan where no drawings exist, with the opening sizes and the ratings wanted for each door marked on them. The surveyor then measures each opening by hand on site, looks over the wall build and the floor levels, checks the threshold, and writes down the closer, the access control and any power supply fitted to the door.

The workshop builds each doorset to the written specification, and the SR2 and fire test papers travel with it. A pack reaches the buyer at handover, holding the fire test papers, the SR2 test papers and the care notes. Send the opening sizes and a photo to [email protected]. A reply lands the next working day, carrying a check of the rating and a price band.

Put SR2 and the fire rating on the same specification line, since a door quoted with one rating only leaves the other duty uncovered.

Frequently asked questions

What does SR2 mean in plain words?

SR2 means the doorset stood up to a three minute forced entry attack with the tool set named for that class. Leaf, frame, hinges, lock and wall fixing were all tested together, and the class fits many shops, offices and service doors in Newcastle upon Tyne.

Is SR2 enough for a shop in Grainger Town?

For many shops, yes: three minutes of resistance covers the tool set a casual intruder carries. A cash room, a control room or a store holding high value stock may need SR3, so the risk at that opening is worth checking before the class is fixed.

Can an SR2 door also be a fire door?

Yes. The SR2 test and the fire test cover the same doorset as built, so the specification should name both ratings in full, each with its own test papers.

How long does an SR2 fire door take from survey to fitting?

Each doorset is made to surveyed sizes, so timing follows the survey and the specification. Dates are set in the reply after the survey, once the opening sizes and the ratings are fixed.

Planning an SR2 fire door for a Newcastle upon Tyne building?

Send the opening sizes and a photo, and a doorset sized for the opening, the SR2 class and the fire class comes back with a price. Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.