Fire · EI 30 to EI 120

SR2 Fire Doors in Coventry

SR2 fire doors for Coventry hospitals, universities, the arena and the station: forced entry and fire resistance in one steel doorset, made to size.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Coventry
Prefer to talk?+44 7352 267239

Get a free quote in Coventry

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Coventry

What we supply in Coventry

More on this

RatingSR2, class B3, three minutes against named tools
Fire gradeE, EW or EI, half an hour, one hour, two hours
BuildSteel leaf and frame, sized from the survey
ReplyAnswer by the next working day

Coventry Cathedral stands in a quarter of galleries, a theatre and a transport museum, and a short walk away the two universities and a large hospital fill whole districts with students, patients and staff. Doors across those buildings face the same double demand: hold back fire on an escape route, then resist a forced entry attempt once the building is shut. SR2 fire doors answer that demand with one leaf, one frame and one set of test papers, instead of two separate doors in one opening.

The forced entry side is SR2, which is class B3: the doorset resists the named tool set for three minutes. The fire side is graded E, EW or EI, at thirty, ninety or one hundred and twenty minutes, from furnace tests on the same build, fitted as it would be on site. Both grades rest on evidence for the same build, so the buyer reads the papers at handover and checks the door that arrives is the door the specification named. Later visits return to those papers, and a grade stands only while the fitted leaf, frame and fittings match the build the papers describe.

That double demand turns up in wards, lecture halls, galleries, plant rooms and station entrances, and it turns up in shops and offices around the city centre too. Wherever a door guards a store by night and an escape route by day, the specification names both grades for the same leaf, so no opening is left half guarded.

Doors the city keeps shut at night, open by day

The cathedral quarter shows the mix at its clearest. Coventry Cathedral holds worship space beside offices, stores and plant rooms, the Herbert Art Gallery and Museum holds galleries beside workshops and storage, and the Belgrade Theatre holds an auditorium beside dressing rooms, scene stores and a public foyer. Doors there meet visitors through the day and guard stores after closing, so each leaf needs a fire grade for the escape route and a forced entry grade for the hours when the building is shut. The museum fire door rules guide covers galleries and stores of this kind.

Coventry University holds teaching blocks, libraries and halls of residence near the city centre, while the University of Warwick holds lecture halls, laboratories and accommodation on its campus at the edge of the city. University Hospital Coventry and Warwickshire holds wards, theatres and plant rooms where beds, trolleys and kit pass through doors all day. A leaf out of use there blocks a route people count on, so fitting is timed around teaching and ward work, the clear opening fits a bed or a trolley, and the threshold is set so a wheel crosses without a jolt. The student accommodation fire door rules guide covers halls of residence of this kind.

The arena by the ring road hosts matches and large events, where doors open for thousands at once and then guard the building overnight. Coventry station holds a public entrance that fills with each train, and shops in the Lower Precinct and West Orchards hold street doors beside stock rooms. In each of those buildings a leaf that holds only one of the two grades leaves its opening half guarded.

Putting both classes on the specification

The specification names LPS 1175 Issue 8.2 (September 2024) alone for the SR classes, and SR2 sits as class B3 under that issue. The fire side names BS EN 1634-1:2014+A1:2018 in the grade line, with E, EW or EI at thirty, ninety or one hundred and twenty minutes. The forced entry standard page and the fire ratings page list the classes in full, while the guide on dual certification for fire and security doors sets out how both ratings are proved on one build.

The closer, lock, hinges and seals are part of the rating itself. They are the set the test papers name, and changing any one of them after fitting can put the rating in doubt. The keeping the rating valid guide sets out what keeps both ratings in force after fitting, the fire door rules for hospitals guide covers ward and theatre doors, and the fire door inspection checklist guide sets out the checks a later visit runs through. Where no forced entry class is needed, fire rated steel doors in the same range carry the fire side on its own.

The handover checks, and the proof each one gives, run as follows.

Item Evidence Why it matters
Test papers SR class and fire grade on one build Proves both grades on one doorset
Survey sheet Sizes taken from the measured opening Proves the doorset fits
Seals Seated all round the frame Hold fire and smoke back
Fittings Closer, lock and hinges as named Show the tested set was fitted
Closing test Leaf shuts fully on its closer Shows the grade works in use

Survey, sign-off and fitting in Coventry

A buyer starts the job by sending the building, the openings and the grades each opening must carry. A reply arrives the following working day with a survey date, and at the survey the surveyor walks each opening, records wall thickness, checks the reveal for damage and photographs the tightest points. Those notes go to the workshop, so the doorset is built for the opening in front of it rather than for a size on an old plan.

The buyer signs the specification before the workshop cuts any metal, since a drawing can be changed in an afternoon and a finished doorset cannot. The installation service fits the doorset, the design service draws it where the buyer needs drawings, and the maintenance service runs the later checks that keep both grades in force. The commissioning and handover guide lists the handover papers the buyer keeps.

Once the doorset is signed off, judge any closer or lock swap against the test papers first. A part from outside the tested set can leave the leaf unproven or hold it open, and the grade paid for can be lost by one small change.

Four questions from Coventry buyers

May this doorset sit on a route people use to leave the building?

Yes, provided the fire grade for that route is written into the specification and the test papers cover the fitted build. While people leave, the leaf holds fire in its compartment; once the building is shut, the same leaf resists a forced entry attempt. Naming route, fire grade and SR class in one place keeps all three in view.

What happens when a listed frontage limits the finish?

The buyer checks with the planning authority before ordering, and any consent limit goes into the specification with drawings of the opening as measured. A finish is then picked to sit beside the stone and brick around it, and the survey notes give the consent papers the same measurements the workshop uses.

Can a lock or closer be changed after the door is fitted?

A swap can put the grade in doubt, since the test papers name the exact fittings the doorset was tested with. Judge any new part against those papers before fitting it, and ask for evidence of its own where it sits outside the tested set. The handover notes carry the fittings list, which is the reference a later change is measured against.

How is an uneven opening in an older building measured?

Each opening is measured at several points, and the build follows the tightest of them rather than an average. Drawings mark where packers go and where seals sit, the frame is made for that tightest point, and the doorset is checked against the survey sheet on arrival at the site.

For a quote on SR2 fire doors in Coventry, tell us the building, which openings need new doorsets and the two grades for each one. Email [email protected] with the building and the openings, or use our contact page. Our base sits at Saffron Road, Romford, Essex RM5 3ES. A reply lands the next working day.

Ready to specify your project?