Fire · EI 30 to EI 120
Fire Rated Steel Doors in Cardiff
Fire rated steel doors for Cardiff hospitals, offices, schools and venues, built to BS EN 1634-1 with test evidence and a reply in one working day.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Cardiff
Get a free quote in Cardiff
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Cardiff
What we supply in Cardiff
Cardiff calls on fire rated steel doors where a stair core, a plant room, a corridor or a service riser has to hold fire and smoke back for a set period. The Senedd and the Wales Millennium Centre stand in Cardiff Bay, the Principality Stadium stands beside the River Taff, the civic buildings line Cathays Park, and offices, hotels and shops fill the city centre, and steel doors guard escape routes and compartment lines across many of those buildings.
What the city holds decides where the doors go. University Hospital of Wales at Heath, the hospitals and clinics across Cardiff, the campuses of Cardiff University and Cardiff Metropolitan University, the schools in the suburbs and the hotels around the Bay each hold doors that shut, latch and seal once the alarm goes off. The fire strategy for the building fixes the rating for every opening, and the leaf, the frame, the seals and the hardware are then treated as one tested unit built to that rating. For rated work across the city as a whole, see physical security in Cardiff.
Which Cardiff buildings ask for these doors first
In Cardiff, the highest ratings usually sit on stair cores and risers in civic buildings and offices. Doors at the Senedd, the civic offices in Cathays Park and the offices of Callaghan Square and Central Square stand on escape routes used by staff and the public, so each opening needs a fire rating that matches the compartment wall around it. The fire door regulations for offices guide runs through how an office schedule treats escape doors, plant rooms and risers.
Hospitals and universities bring a different mix. Wards, operating theatres, pharmacies and plant rooms at University Hospital of Wales answer to one estate plan. Teaching halls, laboratories and student blocks of Cardiff University and Cardiff Metropolitan University spread across the Cathays and Llandaff campuses. A ward door, a drug store door or a laboratory door takes the class the fire strategy for its floor calls for. The fire door regulations for hospitals guide explains how a hospital schedule treats wards, theatres and departments.
Stadiums, hotels and shops form the third group. The Principality Stadium, the hotels around Cardiff Bay and the city centre, the shops at St David’s and the concourses at Cardiff Central station all hold crowds through the day, and their escape doors have to hold shut in a fire yet open freely when people leave in an evacuation. The fire door regulations for schools guide runs through a school schedule for classrooms, halls and stair cores.
How a fire rating works on a steel door
Only the complete doorset holds the rating, because leaf, frame, intumescent seals, hinges, closer and locks were tested as one set. If a part is swapped after that test, the rating no longer has its backing. The rating sums up what the door does under fire, and the specification should list each part with the test evidence that backs it.
Steel doors are classed under BS EN 1634-1, with fire resistance from 30 minutes up to 120 minutes. E stands for integrity, so the door stops flames and hot gases getting through; EW puts a limit on radiated heat; EI adds insulation, which keeps the temperature rise on the unexposed face down. E30 often fits a corridor door, while a stair core or a riser in a tall building may call for EI60 or more. The fire ratings page lists every class in full.
Many Cardiff doors need two duties at once. A plant room door, a riser door or a service door may need a fire rating beside a forced entry class, and the dual certification for fire and security doors guide explains how one doorset can carry both. For forced entry, the scale is set at SR1 to SR5 by LPS 1175 Issue 8.2 (September 2024). A door that needs both ratings must hold test evidence for each. The steel versus timber fire doors guide compares a steel leaf with a timber leaf where the opening takes hard use.
Rating guide for Cardiff openings
Take the table as a rough guide, not a ruling. The class for each opening is fixed by the fire strategy for the building and the person responsible for it, and that happens before a price is put forward.
| Site in Cardiff | Opening | Rating to quote | Door type |
|---|---|---|---|
| Civic buildings and offices | Stair cores and service risers | EI60, or the class the fire strategy names | Steel doorset, fire rated |
| Hospitals and clinics | Wards, theatres and drug stores | EI30 to EI60, with smoke seals fitted | Steel door, fire rated, with seals |
| Universities and schools | Laboratories, halls and stair cores | E30 to EI60, as the fire strategy lays out | Steel door, fire rated, glazed where needed |
| Stadium, hotels and shops | Escape doors and back of house corridors | E30 to EI60, with panic hardware | Steel door, fire rated, with panic hardware |
| Plant rooms and basements | Boiler rooms, electrical rooms and stores | EI60 or higher, as the fire strategy sets it | Solid steel door, fire rated |
Specifying a fire rated steel door in Cardiff
For each opening, begin with the fire strategy and the compartment line the door sits on. From the wall rating, and from what the room is used for, comes the E, EW or EI class, while the how to specify security doors guide lays out what to settle before a price is quoted. The fire door certification guide runs through the evidence that should sit behind the class quoted.
Put the leaf, the frame, the seals and the hardware into one set in the specification, next to the test evidence for the class quoted. Name the finish and the vision panel, the threshold and the access control interface, so the fitted door stays in daily use without losing any of its rating. The plant room fire doors guide looks at the doors that take the heaviest wear in a building.
Where a Cardiff door must hold both a fire class and a forced entry class, put the two on one specification line. The SR2 fire doors page covers a door that carries an SR2 class beside its fire rating. The fire door gaps guide lists the clearances that keep a rated door in working order once fitted.
Survey to fitted doorset in Cardiff
A Cardiff project begins with drawings plus a door schedule giving the class each opening needs. On site, the survey team measures each opening, looks over the wall build and floor level and the pipe and cable runs that cross the frame, and notes the closer, the lock and the door’s daily use. Sizes and the fixing method are set by the survey, and every doorset is built to suit the opening that was measured.
The written specification is what each doorset is built to, and test evidence for the class quoted goes with it. Fitting and handover sit with the installation service, and the fire door maintenance guide runs through the routine checks that keep a doorset in order once it is handed over.
The reply is back inside one working day, giving a budget range, a look at the class quoted and a written specification. Write to [email protected] with the drawings and the class for each opening, or send those same details through the quote form.
Doors, frames and hardware across Cardiff buildings
Check the compartment line first. A class lifted from another building rarely suits a Cardiff door, so put the wall rating and what the room is used for in the enquiry, and both shape the specification.
Questions about fire rated steel doors in Cardiff
Which fire rating fits a Cardiff stair core door?
That is set by the fire strategy for the building. EI60 often fits a stair core door, E30 often fits a corridor door, and the wall the door sits in fixes which one applies.
Can a fire rated steel door hold a forced entry rating too?
Yes, where the doorset has passed tests for both duties. Put the BS EN 1634-1 class and the LPS 1175 SR class on a single specification line, with test evidence for each class.
Do Cardiff hotels and stadiums need fire rated steel doors?
Doors on escape routes, stair cores and back of house corridors in hotels, stadiums and shops often need a fire rating, and the fire strategy for the building sets the class.
What does a Cardiff quote need?
The quote needs drawings, the class for each opening and the wall rating, sent through the quote form or by email, and the reply carries a written specification and a look at the class, with a budget range, all of it back inside one working day.
Need a fire rated steel door for a Cardiff building? Put the drawings and the class for each opening in front of us, and we will come back with a tested doorset for every one.
Other areas
Fire rated steel doors in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.