Blast · ISO 16933 EXV45 to EXV10
Blast Resistant Doors in Cambridge
Blast resistant doors for Cambridge laboratories, hospitals, colleges and the Science Park, with ISO 16933 classes and glazed or solid leaves.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Cambridge
Get a free quote in Cambridge
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Cambridge
What we supply in Cambridge
A blast resistant door holds its frame when a shock wave hits the frontage, and it keeps the opening shut so the pressure wave and the fragments stay outside. A plain steel door bends under that load, and a glazed door without a rated frame loses its pane in the first instant. The blast door is built for that single event, and its frame, its hinges and its lock are tested as one set.
Cambridge gives that door plenty of places to work. The Cambridge Biomedical Campus and Addenbrooke’s Hospital guard entrances where clinical work must carry on behind a shut frontage, the Cambridge Science Park guards laboratories and offices where research equipment sits close to the door, the University of Cambridge guards college and laboratory buildings where students and staff pass through the day, the Grand Arcade guards shopfronts and service doors behind a busy retail frontage, and Cambridge railway station guards service rooms and staff doors beside the public concourse.
A Cambridge buyer begins with the threat, not the catalogue. The charge size the site must face, the distance from the frontage and the use of the building fix the rating first, and the leaf, the glazing and the finish follow that rating. The Cambridge area notes take in the city as a whole, and the blast resistant doors page covers the whole range.
Where Cambridge asks for a blast rated door
The Cambridge Biomedical Campus sets the pattern for the city. Laboratories and clinical rooms sit behind entrances that must stay shut under load, and a blast door there guards a frontage where the work inside cannot stop for a broken pane. Addenbrooke’s Hospital needs the same protection at staff doors and service entrances, where a ward corridor must stay sealed. The hospital door notes carry the same approach elsewhere.
The Cambridge Science Park brings a different set of rooms. Laboratories hold equipment that a shock wave would throw across the bench. The University of Cambridge guards college and laboratory buildings where students and staff pass through the day, and the laboratory door notes set the rating a research building asks for first. The university door notes cover the college entrances.
The Grand Arcade and Cambridge railway station bring the third pattern. Shopfronts and service doors behind a busy retail frontage face the street all day, and the station guards service rooms beside a concourse that fills at peak hours. A blast door in either place guards the rooms behind the public flow.
Glazed or solid, and the rating each Cambridge building asks for
A solid leaf gives the strongest barrier, because the steel skin and the core take the load. A glazed leaf suits an entrance that needs daylight, and its pane is held in a rated frame so the glass stays in place under load. The glazed against solid notes weigh the two leaves side by side, and the blast rating page sets the classes in order.
ISO 16933 sets the blast classes a Cambridge buyer meets first: EXV for a vehicle borne load, and SB for a smaller charge carried by hand. The EXV against SB notes draw the line between the two. EN 13123 and EN 13124 grade windows, doors and shutters for blast load, giving the EPR and EXR classes, and a glazed leaf should be read against those classes as well as its own.
A laboratory door on the Science Park can take SR1, where the A1 test holds hand tools off for one minute. The college entrance suits SR2, and the B3 test against it runs for three minutes. A hospital door that blames LPS 1175 Issue 8.2 (September 2024) blaming a thin leaf for a failed test needs SR3, and the C5 test against that grade runs for five minutes. The station service door takes SR4, where D10 tools are held off for ten minutes. All four grades, with their tool sets, sit on the forced entry standard page.
Fire adds a second rating to the same leaf. A leaf takes its E, EW and EI classes (BS EN 1634-1:2014+A1:2018) over times from 30 to 120 minutes, and a Cambridge door that must hold both ratings is tested for each one in turn. The fire rating page sets those classes, and the dual certification notes set how the two ratings stay valid on one leaf. A steel frame to BS EN 1627 carries a class from RC1 to RC6, and the frame class should match the leaf it holds.
| Cambridge site | Opening | Leaf | Rating |
|---|---|---|---|
| Cambridge Biomedical Campus laboratory | Laboratory entrance off a corridor | Solid leaf, steel frame | EXV, SR2 |
| Addenbrooke’s Hospital staff door | Staff door behind a ward corridor | Solid leaf, steel frame | EXV, SR3 |
| Cambridge Science Park office | Office entrance at street level | Glazed leaf, rated frame | SB, SR1 |
| University of Cambridge college | College entrance with daylight | Glazed leaf, rated frame | SB, SR2 |
| Cambridge railway station service room | Service room beside the concourse | Solid leaf, steel frame | EXV, SR4 |
Use the rows to start the discussion, and let the first visit fix the rating for each opening. The charge size, the distance from the frontage and the width of the opening are noted on that visit, and those figures fix the leaf. Skip those figures and the doors arrive wrong for the openings they must fit.
How a Cambridge blast door is planned and handed over
Walk each opening with the threat in view first. The frame is measured, the wall beside it is checked for the fixings, and the distance to the nearest public route is noted. A blast door in Cambridge sits beside security gates in Cambridge where the entrance needs a forced entry grade as well, and one visit covers both. Advice after the visit comes from the security consultancy in Cambridge page.
A Cambridge hall that holds 800 people at once falls in the enhanced tier, and its duties run further than the plan alone. The new law asks a venue to hold a plan for an attack, to train staff to act on it, and to keep the plan where staff can reach it in a hurry. The Martyn’s Law page puts the tiers side by side.
Halls that hold fewer than 800 people, down to 200, sit in the standard tier. The duties there centre on the plan, the training and the way staff raise the alarm. The calendar for the new duties points to spring 2027, so a Cambridge laboratory should plan its doors with the new duties in view. The fire rated steel doors in Cambridge page covers the door beside the blast leaf when fire protection is asked for too.
The leaf sizes and the rating for each Cambridge opening are filed at our Cambridge bridge Saffron Road, Romford, Essex RM5 3ES. Ask straightaway with the charge size for each opening and the gap to the frontage, and those figures fix the price. Email [email protected] after inspecting each opening, and a written answer lands the next working day, naming the leaf, the rating and the finish for the hardest door. The CDM 2015 duties notes name the holder of each duty on site.
A last check before the Cambridge blast doors are ordered
Look over the schedule once more before ordering, and check each opening against the leaf, the rating and the fire class beside it. An error caught at the desk costs a call, and the same error found after delivery means a door sent back.
Let the threat choose the leaf, because a light glazed door on a hard frontage gives way in the first instant. The leaf, the frame, the hinges and the lock are tested as one set.
Blast door questions from Cambridge buyers
Does a glazed blast door protect as well as a solid one?
A glazed leaf can hold the same blast class as a solid leaf, because its pane is held in a rated frame that keeps the glass in place under load. The glazed against solid notes weigh the two leaves side by side.
Can a Cambridge laboratory door hold a blast rating as well as a fire rating?
Yes, when the leaf passes a test for each rating in turn. The fire standard tests a leaf for E, EW and EI, and the time on the schedule runs from 30 to 120 minutes. The dual certification notes set how the two ratings stay valid on one leaf. The schedule should name both ratings for the leaf.
What does EXV mean on a Cambridge blast door schedule?
EXV is an ISO 16933 class for a vehicle borne load, while SB covers a smaller charge carried by hand. The class on the schedule comes from the charge size and how far the frontage sits from the public route. The EXV against SB notes set the two apart in full.
How long does a blast door for Addenbrooke’s take from order to fitting?
The time turns on the size of the leaf, the rating and the finish. The schedule names the date for each door once the first visit fixes the sizes. Order the survey early, so the date is fixed before building work starts.
Blast resistant doors for a Cambridge building?
Send the opening sizes and the charge size for each room, and the quote covers leaves, frames, hinges and locks together. Get a free quote