Certified physical security

ArxBridge
Honey stone building with a discreet modern security door in Oxford

Perimeter and HVM · PAS 68 and IWA 14-1

Security Gates in Oxford

Security gates for Oxford colleges, hospitals, science parks and yards, with LPS 1175 and vehicle impact ratings, automation and a written specification.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Oxford
Prefer to talk?+44 7352 267239

Get a free quote in Oxford

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Oxford

What we supply in Oxford

More on this

Oxford is a city of colleges, hospitals and science parks behind old walls and narrow lanes, and its gates have to work inside that pattern. A gate on an Oxford entrance must let the right vehicles and people through, stay shut for the rest, and hold its line when it is pushed, climbed or driven at.

The form follows the entrance. College and hospital entrances with room to swing take a hinged gate, long boundaries take a sliding leaf that runs back beside the fence, yards where a track would clog with grit take a cantilever leaf, and people use a pedestrian gate beside the vehicle lane, apart from the vehicles. Security gates are sized to the entrance, not taken from a shelf size.

Oxford puts its own pressures on that choice. Entrances sit tight against pavements and bus routes, run back room for a gate is often short, and listed walls and conservation areas shape what can be fixed to a boundary. Gate type, rating, automation and safety devices belong in a single decision, made before the groundwork starts, and the physical security in Oxford area page shows how those uses sit across the city.

Colleges and schoolsCollege lanes, Headington and Summertown sites
Hospitals and scienceJohn Radcliffe, Churchill and science park sites
Yards and depotsCowley works, Kidlington and Botley Road yards
Retail and stationWestgate, Covered Market and station approaches

Where Oxford sites need security gates

Colleges and schools need gates that work to a timetable. A college gate opens for students, staff and deliveries at fixed times and stays closed between them, while a school gate holds a clear pedestrian route beside the vehicle lane. The education sector page describes how a campus plans its entrances, and the pedestrian gates guide shows how the two lanes are planned as one.

Hospitals and science parks need a different balance. The John Radcliffe Hospital and the Churchill Hospital must keep the ambulance route open at all hours, and the science park sites to the south of the city must let maintenance vehicles in while keeping each compound shut at other times. A gate on such a site sits beside fencing and bollards on the same boundary, and the hospital security gates guide covers the ambulance route and the service entrance together.

Yards, depots and retail sites form the third group. The works at Cowley, the yards around Kidlington and Botley Road, and the service entrances behind Westgate Oxford and the Covered Market all need gates that take heavy vehicles through the day. Security bollards beside the gate shut the gap a vehicle could use to slip past it.

Ratings that govern security gates in Oxford

Gates take their forced entry rating from the September 2024 issue of the standard, and the tender points LPS 1175 Issue 8.2 (September 2024) later in the specification, after the gate form and the leaf size are set. The scale runs SR1 to SR5, and each class names the tools and the attack time the gate must resist. The LPS 1175 standard page sets out every SR class. The LPS 1175 gates and grilles guide reads those classes against a gate leaf and its posts.

A gate that must stop a vehicle is judged on a different scale. ISO 22343-1:2023 is the standard now in force for vehicle security barriers, and a vehicle rated gate takes its class, its vehicle weight, its speed and its penetration distance from that document. PAS 68:2013 was taken off the list in October 2023, so a class from that document on its own no longer counts. The vehicle impact ratings page lays out the current scale, and the anti-ram gate and barrier guide covers gates built to stop a vehicle.

A powered gate brings a safety standard of its own. The powered leaf needs safety edges and photocells that stop it on contact, a limit on the closing force, and controls that drop to a safe state, so people can still get out if the power cuts. The gate automation guide sets out which safety devices belong on a powered gate. The schedule points BS EN 1634-1:2014+A1:2018 behind the fire door entries, so the gate entries carry no fire class of their own.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Rating guide for Oxford gates

Use the table as a rough starting point only. The survey of the site decides the class for every entrance, weighing the traffic, the hours the site lies empty and the kit an intruder might carry.

Oxford entrance Gate form Rating to ask for Control
College or school entrance Hinged vehicle gate and pedestrian gate LPS 1175 SR2 Timed opening, access control
Hospital entrance Sliding vehicle gate, ambulance route kept clear LPS 1175 SR2 Intercom, barrier control
Science park compound Cantilever vehicle gate with mesh infill LPS 1175 SR2 or SR3 Card reader, intercom
Yard or depot, Cowley or Kidlington Sliding vehicle gate on a track LPS 1175 SR2 or SR3 Keypad, intercom
High vehicle threat site Vehicle gate and rising barrier ISO 22343-1 vehicle class Intercom, barrier control

How to specify security gates in Oxford

Begin at the boundary. A college lane leaves little room for a leaf to swing out, a long fence line gives a sliding leaf somewhere to run back, and a yard with soft or uneven ground may suit a cantilever leaf better than a track. Measure the clear width and height, the run back room, the swing arc and the ground levels, and check the pavement and the drainage before the form is fixed.

Settle the rating and the infill next. A solid leaf hides the site and resists climbing, a barred leaf keeps sight lines open for a school or a car park, and a mesh infill suits a depot that needs air and light. Leaf, posts, hinges or rollers and lock must carry test evidence for the same SR class together, because a strong leaf on weak posts carries no tested rating. Sliding vehicle gates show the form for the widest yard entrances in the city.

Finish with the motor and the access control. The motor must match the leaf weight and the cycles each day, with a hand release for a power cut and safety devices that halt the leaf on contact. Intercoms, fobs, card readers and number plate readers suit different flows of users, and the security gates cost factors guide lays out which choices move the price.

Project steps for security gates in Oxford

The survey opens the job, at the entrance itself. Opening size, ground levels, leaf travel, power supply and drainage are recorded, and the pavement, the listed wall or the conservation area beside the boundary is noted. A photograph and a sketch of the boundary go into the file, so the specification comes from the site as it stands.

Then the written record sets out the rating and the form for each entrance: the SR class, or the vehicle rating under ISO 22343-1, with leaf size and infill, motor and controls. The perimeter range lists the gate, bollard and barrier forms the record draws on, and the test evidence for the rated gate travels with the gate to handover.

Foundations, ducts and drainage come before the leaf, laid to the levels the survey recorded. Pass on the entrance sketches and the rating the gate must meet by writing to [email protected], or add the same details on the quote form. The reply lands inside one working day, naming the specification, the checked rating and a price range.

Fix the leaf travel before the foundation is dug. A sliding leaf with nowhere to run back cannot open, and a swing leaf with no arc to turn in cannot open either, so the survey must settle the form first.

Questions about security gates in Oxford

Sliding gate or swing gate for an Oxford college?

The boundary decides. A long fence line gives a sliding leaf somewhere to run back, and a short entrance with room to turn suits a hinged leaf. Where the pavement sits close to the boundary, a leaf that swings out onto the highway is usually ruled out.

Do security gates in Oxford need planning permission?

Sometimes, and the survey should check before the specification is fixed. Height, position beside a highway, listed status and conservation area rules all play a part, and a listed wall needs consent for a change to the boundary.

How does a powered gate behave when the power fails?

Staff use the manual release, and the controls fail safe so people can still leave. Put the release method and the fail safe position in the specification, and show staff how the release works at handover.

Can a gate and a pedestrian lane share one Oxford entrance?

Yes, and most college and hospital entrances work that way. People use a pedestrian gate beside the vehicle lane, apart from the vehicles, with its own access control and its own timed opening, while the vehicle leaf handles deliveries and service traffic.

Need a gate for an Oxford entrance? Send the sketch and the rating, and the specification follows by return.

Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.