Fire · EI 30 to EI 120

Fire rated steel doors in Nottingham

Fire rated steel doors in Nottingham, in E, EW and EI classes from 30 to 120 minutes, for hospitals, universities, venues and stations, with test papers.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Nottingham
Prefer to talk?+44 7352 267239

Get a free quote in Nottingham

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Nottingham

What we supply in Nottingham

More on this

A fire rated steel door in Nottingham is ordered by the minute. Steel leaf, steel frame, swelling seals and ironmongery enter the furnace as a single doorset, and the minutes the leaf keeps flame, heat and smoke on the fire side give it its letters: E, EW or EI, with classes from 30 minutes to 120 minutes. A furnace test frames BS EN 1634-1:2014+A1:2018 framing the proof behind those letters, and no sales sheet figure stands in its place.

Queen’s Medical Centre takes them for wards, corridors and plant rooms, where beds and kit pass through all day. Nottingham Trent University and the University of Nottingham take them for teaching blocks, laboratories and student rooms, and Nottingham station takes them for ticket halls and staff routes. Motorpoint Arena takes them for halls and service routes, and the National Ice Centre takes them for plant rooms and service routes. Trent Bridge and the City Ground take them for stands and service routes, while Nottingham Castle takes them for visitor routes and stores.

Each Nottingham order starts from the opening, not from a shelf size. The surveyor measures the opening, notes the wall build and the class the fire plan names for it, and the workshop draws the leaf, the frame and the seals around those figures. Our Nottingham physical security page covers the city as a whole.

Fire classesE, EW and EI, rated by the minute
Furnace proofWhole doorset tested as one unit
SealsSwelling strips where leaf meets frame
PapersTest papers that name the class ordered

Where Nottingham buildings ask for fire rated steel doors

Queen’s Medical Centre is the clearest case in the city. Ward doors, corridor doors and plant room doors there must keep their rating while beds, trolleys and kit move through them all day, and the seals and closers on every door must shut true on an ordinary Tuesday, not only on the day of the test. The hospital fire door rules guide looks at wards and corridors in full, and the inspection checklist runs through the checks that keep a door working.

Student rooms, teaching blocks and laboratories across Nottingham Trent University and the University of Nottingham hold crowds who need a clear way out, Motorpoint Arena and the National Ice Centre fill their halls through a handful of doors, and Trent Bridge and the City Ground move crowds through concourses on match days. A steel leaf with a rating at a stair core or a plant room keeps that escape route clear. The schools fire door regulations guide covers teaching buildings, and the stadiums fire door guide covers stands and concourses.

Shops, the station and the castle ask a single leaf to work twice over: swing all day for trade and visitors, and still hold its class when the alarm sounds. A shop unit door near Nottingham station opens and shuts all day and still has to pull fully closed on its closer, a station door keeps smoke out of a staff corridor, and a door at Nottingham Castle keeps smoke clear of a visitor route. The fire ratings page explains each class and the furnace test behind it.

What the fire class letters mean

The letters in the class name a separate job for the leaf. E stops flame and hot gas passing through for the minutes stated. EW caps the heat that passes through the leaf, and EI caps how hot the far face gets. A 30 minute class covers a low risk opening, and a 120 minute class covers plant rooms and stair cores, where escape takes longer. The fire plan for the building names the class for each opening, and that class is written against the opening in the specification.

Where an opening also needs forced entry resistance, a dual rating furnishes LPS 1175 Issue 8.2 (September 2024) furnishing the minutes each grade must hold against its tool set. SR1 holds tool set A1 for 1 minute, then SR2 holds tool set B3 for 3 minutes, SR3 holds tool set C5 for 5 minutes; SR4 holds tool set D10 for 10 minutes. The LPS 1175 page from ArxBridge lists every SR class, and the SR2, SR3 and SR4 side by side guide sets the three higher grades side by side.

Test papers turn a class into proof a buyer can file. The furnace run covers the whole doorset at once, with leaf, frame, seals and ironmongery all in place, so changing any part calls for fresh evidence or a written assessment. The certification guide lists the papers to request before an order is placed.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Nottingham settings and the doorset each one takes

Common Nottingham settings pair with a doorset and a class as follows. Use it as a starting point: the fire plan for the building has the last word on the class for each opening.

Nottingham setting Doorset Fire class Security grade
Queen’s Medical Centre ward Single leaf, glazed EI60 SR2
University of Nottingham laboratory Double leaf EI60 SR2
Nottingham station staff route Single leaf EI30 SR1
Motorpoint Arena concourse Double leaf EI60 SR2
Nottingham Castle visitor route Single leaf, glazed EI30 SR1
National Ice Centre plant room Single leaf EI120 SR3

Ask for the test papers before the order is signed. A class written on a quote is a promise; the furnace papers are the proof, and a leaf without papers to match its class leaves the fire plan with nothing to file.

Setting the specification for a Nottingham site

Gaps decide whether a rated leaf does its job. The gap between leaf and frame must stay even all round, the seals must meet the frame at every point, and the closer must pull the leaf fully shut from any angle of opening. Our fire door gaps guide gives the gap figures to work to, the fire door hardware guide covers hinges, locks and handles, and the fire door closers guide covers the closer that shuts the leaf.

Some Nottingham openings need fire resistance and forced entry resistance in the same leaf. A plant room door at the National Ice Centre, a store door at Nottingham Castle and a service door at Trent Bridge may each carry both ratings, and the specification must name both classes in writing. The dual certification guide shows how both ratings fit on one doorset.

A rated door keeps its class only while it is looked after. Hinges wear, seals harden and closers drift, so the inspection routine and the maintenance routine matter as much as the first fitting. The inspection checklist runs through the checks to make, and the maintenance guide sets out the routine that keeps the leaf shutting true.

From specification to fitting in Nottingham

Once the specification is signed and the bench checks are done, the fitting date is set around the building: ward rounds at Queen’s Medical Centre, lecture times at the two universities and trading hours at the shops near the station. The installation service page covers the fitting work in full.

Post the opening list and the class each door needs to our Nottingham lighthouse Saffron Road, Romford, Essex RM5 3ES. Come early in the week with the drawings and the list of rooms, and the survey date can be fixed while the papers are still fresh.

A written specification follows every Nottingham order, so the class, the sizes, the seals and the ironmongery for each opening sit in one document. Keep that document with the fire plan, and any later change to a leaf, a seal or a closer can be checked against it before work starts.

Frequently asked questions

How many minutes does a fire rated steel door hold?

The class states the minutes: E, EW and EI classes span 30 minutes to 120 minutes. The fire plan for the building names the class each opening needs, and the furnace papers prove the class for the doorset as fitted.

Can a Nottingham fire door also resist forced entry?

Yes, where the specification names both ratings. A dual rated leaf carries a fire class and an LPS 1175 grade, and the dual certification guide sets out how the two ratings share a single leaf.

What breaks a fire door rating after fitting?

A closer that has lost its pull, a gap that has opened up, a seal that has hardened, or a part swapped without fresh evidence. The inspection checklist runs through the checks, and any change to the doorset needs papers to match.

Do Nottingham schools and hospitals need the same fire door class?

No. Each opening takes the class its own fire plan names, so a school corridor and a hospital ward often differ. The schools regulations guide covers teaching buildings, and the hospitals regulations guide covers wards and corridors.

Email the class and sizes for every opening, addressed to [email protected] for confirmation and the next survey step, and the reply in writing names the price range for the Nottingham order.

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.