Certified physical security

ArxBridge
Victorian factory conversion with a navy steel door in Leicester

Perimeter and HVM · PAS 68 and IWA 14-1

Sliding vehicle gates in Leicester

Sliding vehicle gates in Leicester for depots, hospitals, campuses and service yards, with leaf, track, drive and safety set out for each entrance.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Leicester
Prefer to talk?+44 7352 267239

Get a free quote in Leicester

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Leicester

What we supply in Leicester

More on this

A Leicester yard, depot or service entrance can take a gate whose leaf runs sideways on a track, so the entrance opens without anything swinging into the road and traffic keeps moving past it. Leaf, track, rollers and drive are matched to the opening from its measured width, the fall of the ground and the vehicles that use it, and the gate stays true only when its bed is level and the space beside the opening stays clear for the leaf to park in. An order for a sliding vehicle gate covers that leaf alone, while rated gate leaves in full are covered on the LPS 1175 gates and grilles page.

Leicester gives that gate plenty of entrances to guard. Yards and depots around Braunstone and Beaumont Leys open for lorries through the working day, Leicester Royal Infirmary runs a yard gate for its deliveries and waste vehicles, and the two universities run campus gates that keep teaching areas away from service roads. King Power Stadium opens service entrances for event traffic, the National Space Centre and the Curve keep yard gates beside their public areas, and Highcross and the Haymarket keep service gates behind retail units. The wider Leicester picture is on the physical security in Leicester page, and the gate is sized to the entrance it guards.

Sideways runLeaf runs sideways on its track, so the road needs no swing room
Sized to fitLeaf, track, rollers and drive are sized from the opening width and the fall of the ground
Rated where neededLeaf, frame and lock tested to the SR grade where the order names one
Written recordWidth, drive and safety devices written down before the order is placed

Leicester entrances that suit a sliding leaf

A sliding leaf suits depots and yards first, because a leaf that swings would cut across the road or the yard at every move. A yard in Braunstone or Beaumont Leys takes lorries through the working day, and with the leaf parked beside the opening while open, the entrance stays open for the next vehicle. Yard entrances in full are covered on the warehouse security gates page, and service yards where deliveries and waste vehicles share one entrance are covered on the hospital security gates page.

Hospitals, campuses, stadiums and shops use the same leaf where the entrance sits tight against a public road. Leicester Royal Infirmary shares one service yard gate between deliveries and waste vehicles, the two universities keep campus gates between teaching areas and service roads, King Power Stadium opens its service entrances on event days, and Highcross and the Haymarket keep gates for the service yards behind their shops. A sliding leaf needs no swing room, so it suits entrances where pavement or road runs close to the gate.

How a Leicester sliding gate earns its grade

The rating schedule names a grade for the leaf, the frame and the lock to be judged against together. The schedule illustrates LPS 1175 Issue 8.2 (September 2024) placing the class the entrance needs. SR1 holds for one minute against tool set A1, SR2 for three minutes against B3, SR3 for five minutes against C5 and SR4 for ten minutes against D10. Every part is tested to the grade named in the specification, so a strong leaf held in a weak frame fails, and a sound lock on a frame that bends fails with it. The LPS 1175 page lists the full scale, and the grade named on the order is the grade the gate must meet once it is fitted.

Rollers carry the leaf on a track set into the ground, or a cantilever frame carries it where a ground track will not stay clear, and ground, traffic and daily use of the entrance decide between the two. A tracked gate needs its bed level and its rail kept free of stone and grit, while the cantilever form needs a firm frame and a counterweight that keeps the leaf steady across its full travel. What shapes the price of leaf, track and drive is explained on the automatic gates cost factors page, motors, safety edges and photocells are covered on the gate automation page, and gates that must also hold back a vehicle are covered on the anti-ram gates and barriers page.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Choosing the leaf, track and drive

Ratings that apply where a vehicle impact forms part of the risk are given on the vehicle impact ratings page. The leaf is fixed by width, height and wind load, with a solid leaf for privacy and a barred leaf that lets staff see through the entrance. Weight and opening rhythm fix the drive, with a light duty motor serving a gate used now and then and a heavy duty motor serving a depot gate worked through the day. The checks to run before the order is placed are listed in the guide to due diligence for vehicle security barriers.

Where the gate stands in a hostile vehicle mitigation line, what sits beside the leaf matters as much as the leaf itself. PAS 68:2013 gave way to ISO 22343-1:2023 on 25 October 2023, so the impact rating on the order names the current standard. The wider line is covered on the hostile vehicle mitigation page, the move from PAS 68 to ISO 22343-1:2023 is explained on the HVM standards page, and the gate forms only one part of the line.

Entrance Leaf Drive Site check
Depot yard Solid leaf in steel Motor for frequent use Track, rollers, safety edges
Hospital service yard Barred leaf Motor for standard use Photocells, lock, track bed
Campus service road Barred leaf Motor for standard use Run-back clear, rollers
Stadium service entrance Solid leaf in steel Motor for frequent use Lock, drive force, safety edges

Fitting and upkeep through the year

The ground comes first, with the bed for the track dug out, levelled and made ready before the leaf is hung, and the surveyor then measures the width of the opening and the fall of the ground along the run and the clear run-back next to it, so the leaf stands fully clear of the entrance when open. What the site should agree before fitting is covered in the guide to writing an operational requirement.

Upkeep is mostly cleaning and checking: the rail is swept clear of stone and grit, wear is checked on the rollers, the safety edges and photocells are tried, and the drive force is checked against the leaf meeting an obstruction. A leaf that sticks, a grinding roller or a safety edge that has stopped working is fixed before the next visit, so the gate stays true through wet months and dry months. The checks at each visit are named in the in service care for vehicle security barriers guide, and how gate, access control and barriers are timed together is covered in the guide on programming a security door and barrier package.

Email the width of the entrance, the fall of the ground and the vehicles that use it to [email protected] during the working week, and the reply, in one working day, brings the leaf size, the drive type and the price. Post goes to the Romford hub Saffron Road, Romford, Essex RM5 3ES each item marked with the site name and the entrance width, so the papers reach the right file.

What to send with a Leicester sliding gate enquiry

Open the enquiry with the width of the entrance, the fall of the ground and the clear run-back beside it, since a leaf built for one entrance rarely suits the next.

Questions about sliding vehicle gates in Leicester

How much run-back room does the opening need?

The bed is made level before the leaf is hung, and the survey measures the fall of the ground across the run. Where the bed sinks, or grit fills the rail, the leaf starts to drag and the rollers wear quickly, so the rail is swept clear at every visit.

What happens if the power goes off?

The drive carries a manual release. Once the site team has been shown the release at handover, staff can move the leaf by hand when the power is off. The handover sheet shows where the release sits and how it is used, and the release is tried by hand at each visit.

Can a sliding gate stop a vehicle that strikes it?

Only where the gate carries a tested impact rating and the specification names it, such as one under ISO 22343-1:2023. A standard gate keeps people out and slows entry, yet it carries no impact rating, so the risk assessment should name the rating where vehicle impact forms part of the risk.

How much clear run-back must sit beside the opening?

The leaf parks beside the opening while it stands open, so the run-back must hold the whole width of the leaf clear of bins, parking and planting. The run-back is measured at the same visit as the width of the opening, and the gate is ordered only where the clear run-back suits the leaf.

Need a sliding vehicle gate for a Leicester entrance? Send the width of the entrance, the fall of the ground and the vehicles that use it, and the reply sets out leaf, drive and price.

Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.