Certified physical security

ArxBridge
Canalside offices with a navy steel entrance door in Birmingham

Perimeter and HVM · PAS 68 and IWA 14-1

Sliding Vehicle Gates in Birmingham

Sliding vehicle gates for Birmingham depots, schools and business parks, rated for impact and forced entry and built for daily use at busy entrances.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Birmingham
Prefer to talk?+44 7352 267239

Get a free quote in Birmingham

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Birmingham

What we supply in Birmingham

More on this

A sliding vehicle gate travels sideways across its opening, running on a ground track or hanging from a cantilever frame, so a wide entrance can open and close without a swing arc. That matters in Birmingham, where depots, warehouses, schools and business parks often sit on tight plots with a public pavement close to the gate line. A leaf that swings out would block the pavement, and a leaf that swings in would eat the yard. Sliding vehicle gates keep the whole leaf inside the boundary at every point of its travel.

The ground decides much of the design. A tracked gate needs a level run and a clear track, while a cantilever gate hangs clear of the ground and suits a yard where snow, leaves or loose stone would block a rail. The leaf weight, the number of vehicle movements each day and the wind load on a solid infill all feed into the motor size and the frame section. Those figures should be fixed before the order, not after the gate is built.

Buyers in Birmingham order sliding gates for distribution depots near the NEC and Birmingham Airport, for school entrances, for hospital service yards and for business parks on the edge of the city. The gate can stand alone at a side entrance or sit beside security gates, barriers and bollards at a main entrance. More Birmingham work, from doors to barriers, sits on our physical security in Birmingham page.

ProductSliding vehicle gate, tracked or cantilever
RatingImpact rated to ISO 22343-1, forced entry to LPS 1175
UseDepots, schools and business parks
Reply timeOne working day

How a sliding vehicle gate moves

The leaf runs on rollers or hangs from a top frame, driven by a motor that pulls it sideways across the opening. A tracked gate sits on wheels that run in a rail fixed into the ground, which holds the leaf steady in wind but needs that rail kept clear of debris. A cantilever gate has no rail in the ground; the leaf hangs from rollers on a support frame and needs a longer run beside the opening to balance its weight. The choice turns on the ground, the space beside the opening and the way the yard is used.

Control comes from the same point as the rest of the entrance. The guide to gate automation sets out the control options, from a simple key switch to a system tied to access control and intercom. The motor, the safety edges and the control panel should be named in the same specification as the leaf, because a gate that opens well but stops badly is not fit for a busy entrance.

Birmingham entrances that suit a sliding leaf

The table that follows pairs each Birmingham entrance type with the gate detail that matters most at that entrance.

Entrance in Birmingham Gate detail that matters most
Distribution depots near the NEC Wide leaf, heavy duty motor and control that handles frequent vehicle movements
School entrances Separate pedestrian route, safety edges and a leaf speed that suits children crossing nearby
Hospital service yards Quiet running, a leaf that clears delivery vehicles and access for service staff at all hours
Business park main entrances A smart finish, intercom and access control tied to the tenant system
Birmingham Airport service roads A leaf built for constant use, with a motor and rollers rated for high cycle counts

Depots near the NEC and the airport run vehicles through the gate all day, so the motor and the rollers carry the load that decides the life of the gate. The anti-ram gates and barriers, explained explains the difference between a gate that stops a vehicle and a gate that only controls access, and why the two jobs need different ratings.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Two ratings, two jobs

A sliding gate can carry two ratings, and they test different things. An impact rating tests whether the gate stops a vehicle of a stated weight at a stated speed. A forced entry rating tests whether the gate holds out against hand tools for a fixed length of time. A gate can pass one test and fail the other, so the specification should name each rating that the entrance needs, with the standard in full.

The vehicle impact ratings page lists the impact classes, and the LPS 1175 page gives the forced entry grades. The test record that stands underneath LPS 1175 Issue 8.2 (September 2024) lays out the top grades first: SR4 as D10, then SR3 as C5. The lower grades follow the same pattern, SR2 as B3 and SR1 as A1.

Leaf size alone says nothing about what a gate can stop. Two leaves of the same width can hold different ratings, so the class and the standard in the test papers are the only proof of what the leaf can stop.

The current impact standard is ISO 22343-1:2023, which supersedes PAS 68:2013. From 25 October 2023 that standard no longer counted as current. An old specification that still names PAS 68 should be updated before anything is ordered. The HVM standards guide, from PAS 68 to ISO 22343 sets out how the change affects a gate specification and what to ask for in place of the old rating.

Power, control and keeping people safe

A powered gate must halt when a person or a vehicle crosses its path. Safety edges on the leaf, photocells across the opening and a motor that reverses on contact all form part of the safety system, and each one should be tested at handover. The gate should also fail safe: a power cut must not leave the entrance open to any vehicle, and it must not trap a vehicle inside the yard. The way the gate behaves without power should be written down before the order, not found out during the first outage.

Access control decides who can open the gate and when. A key switch suits a yard with few users, while a site with many staff or tenants needs fobs, codes or a link to the building system. The price follows the leaf, the motor, the control panel and the safety gear, so each of those items should be named in the specification before anything is ordered.

From survey to fitted gate in Birmingham

It begins with a visit. The surveyor walks the Birmingham entrance, tapes the opening and the run beside it, levels the ground across the yard and finds where power reaches the gate line. From that visit we draft the specification: leaf, motor, ratings and control system, all set down for the buyer to sign before we order anything.

Delivery brings the leaf to the Birmingham site on a day agreed with the buyer, and the fitting crew sets the track, hangs the leaf and tests the safety edges before handover. The buyer receives the test records and the operating notes together in a single handover pack.

Frequently asked questions

How much space does a sliding gate need beside the opening?

A tracked gate needs a run at least as long as the leaf, clear of planting, bins and parked vehicles. A cantilever gate needs a longer run, because part of the leaf stays behind the support frame to balance the weight. The survey measures the run and records anything that blocks it.

Can a sliding gate stop a vehicle?

Only a gate with a named impact rating, tested to ISO 22343-1, can be described as stopping a vehicle. A standard sliding gate controls access; it is not an impact barrier. The rating should be named in the specification, with the vehicle weight and speed from the test.

What happens to a sliding gate in a power cut?

That depends on the design agreed at specification stage. Some gates can be released by hand from inside the site, while others hold shut until power returns. The behaviour without power should be written down before the order, so nobody finds it out during an outage.

Do sliding gates suit a sloping entrance in Birmingham?

A slope across the gate line suits a cantilever gate better than a tracked gate, because the leaf hangs clear of the ground. The survey records the fall across the opening, and the specification names the gate type that fits that ground.

Ask for a quote for sliding vehicle gates in Birmingham

Send the gate width and the site address to [email protected] and our reply reaches you inside one working day. A surveyor then visits the entrance to measure the run and the ground. Contact ArxBridge to start.

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.