Perimeter and HVM · PAS 68 and IWA 14-1
Sliding Vehicle Gates in Edinburgh
Sliding vehicle gates in Edinburgh for depots, campuses, hotels and yards. Tracked or cantilever, LPS 1175 rated and automated, specified for each opening.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Edinburgh
Get a free quote in Edinburgh
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Edinburgh
What we supply in Edinburgh
Sliding vehicle gates in Edinburgh suit the sites where a swinging leaf has no room to open: a yard behind a hotel, a service entrance on a campus, a depot gate on a narrow street. The leaf runs sideways on a track or hangs from a beam, so the full width stays clear for vans and lorries, and the gate can carry a forced entry class and an impact class on the same frame. Depots around Leith and Newbridge, campuses at Riccarton and George Square, and hotels in Princes Street and George Street all have entrances where only a sliding leaf fits.
Edinburgh gives a sliding gate two problems to solve at once. The Old Town holds closes, wynds and narrow lanes where a gate line may sit between stone walls with little room at either side, while the New Town holds mews lanes behind Georgian townhouses where a gate must open without swinging across a pavement or a shared lane. Rain, frost and leaves add their own trouble to a ground track, so the choice between a tracked leaf and a cantilever leaf follows the ground and the drainage. More rated work across the city sits on the physical security in Edinburgh page.
Where Edinburgh puts a sliding vehicle gate
Depots and yards put them at the main entrance. Sites around Leith, Newbridge and the city ring road run lorries, vans and plant through one gate all day, and a sliding leaf leaves the full opening clear while the yard stays shut to the street. The leaf must take knocks from vehicles, the track or beam must stay true under daily use, and the access control must let authorised drivers through. The warehouses and logistics sector page details how depots and yards arrange their entrances.
Campuses and hospitals put them at service yards and rear entrances. Heriot-Watt at Riccarton, the University of Edinburgh around George Square and the Kings Buildings, and the Royal Infirmary at Little France all run deliveries, waste collection and maintenance vehicles through yards close to pedestrian routes, so the gate must separate vehicles from people on foot while letting service traffic through on a schedule. A sliding leaf suits these yards because it opens along the fence line.
Hotels, venues and mews lanes form the third group. Hotels along Princes Street, George Street and the Royal Mile take deliveries and linen vans through rear lanes, venues near the festival sites need a service gate that can stay shut through a performance, and mews lanes behind New Town townhouses hold garages behind gates that must open in a lane barely wider than a van. The security gates cost factors guide details what moves the price of a gate of this kind.
Tracked or cantilever, and which rating
The ground decides the type. A tracked gate runs on a rail in the ground, which suits a level yard with good drainage, while a cantilever gate hangs from a beam and clears the ground, which suits a yard where the ground falls across the opening, where drains cross the gate line, or where frost and leaves would block a rail. The survey measures fall and drainage before either type is named, and the gate automation guide details how the motor, the safety edges and the access control sit on each type.
The rating follows the risk at the gate. LPS 1175 Issue 8.2 names the SR classes for gates, and the September 2024 issue keeps the scale at SR1 to SR5, so the class comes from the risk assessment for that entrance rather than the size of the site. The LPS 1175 standard page names the SR classes, and the guide on LPS 1175 gates and grilles details how the classes apply to a gate leaf and frame.
Vehicle impact needs its own class on the same gate. The vehicle impact test now sits in ISO 22343-1:2023, and PAS 68:2013 was withdrawn during October 2023, so a specification should name the ISO 22343-1:2023 class and never quote a PAS 68 class for new work. The vehicle impact ratings page gives the impact scale, and the ISO 22343 vehicle security barriers explained guide details how the test works. A powered gate also carries safety duties for the operator and the safety edges, and those duties sit in the specification beside the ratings.
Rating guide for Edinburgh sliding gates
Read the table as a broad pointer, not a decision. The risk assessment settles both classes, and the survey settles the gate type before pricing.
| Site in Edinburgh | Gate type | Ratings to quote | Drive and safety note |
|---|---|---|---|
| Depot or yard | Tracked, level ground | SR2 to SR3, plus ISO 22343-1 class | Motor sized to leaf weight |
| Campus service yard | Cantilever, ground falls | SR1 to SR2, plus ISO 22343-1 class | Pedestrian route kept clear |
| Hotel rear entrance | Tracked or cantilever, per the lane | SR1 to SR2 | Quiet motor and timed closing |
| Mews or tight lane | Cantilever, no swing room | SR1 to SR2 | Leaf runs along the fence line |
Specifying a sliding gate in Edinburgh
Begin with the opening, the ground and the traffic. Name the clear width, the fall across the opening, the drainage around the gate line and the vehicles that use it, then set the gate type, the SR class and the impact class on one line for the same leaf and frame. The due diligence vehicle security barriers guide details the checks to run before a gate is ordered, and the vehicle dynamics assessment explained guide details how approach speed and angle shape the impact class.
Name the leaf, frame, track or beam, motor, safety edges, access control and foundations as one gate unit, with the test evidence for both classes beside them. Include the finish, the power supply and the manual release, so the gate keeps working through a power cut and a full winter of use. Where the entrance also needs a pedestrian gate beside it, set that gate on its own line with its own class, and the security gates page gives the wider range to choose from.
Planning permission needs its own step in the specification. A gate that faces the highway, sits in a conservation area or forms part of a listed building may need permission from the City of Edinburgh Council, and a tall gate beside a pavement can need it too. Note the position, the height and the listing grade, and check the permission position before any steel is ordered. Where the risk runs higher than a gate alone can hold, the hostile vehicle mitigation page gives the barriers that sit with it.
Survey to working gate in Edinburgh
A gate job in Edinburgh begins with drawings or a schedule naming the opening width, the gate type and the ratings for each gate. On site, the surveyor tapes the opening, checks the fall across the gate line, the drainage, the power supply and the foundations, and watches how vehicles and people on foot use the entrance through a working day. Those figures settle the leaf size, the beam or track and the motor.
Fitting is part of the installation service. The guide on anti ram gates and barriers details how a rated gate line holds together.
Use the quote form for the opening width, the ground fall and the rating the gate must hold, or write to [email protected]. The first answer lands by the next working day, with the rating checked, a price figure and the specification in writing.
Gates, ratings and records for Edinburgh entrances
Send the opening width, the ground fall and the rating the gate must hold in the enquiry, with the listing grade where one applies. A gate lifted from another yard rarely fits an Edinburgh entrance, so send all three figures with the enquiry.
Questions about sliding vehicle gates in Edinburgh
Tracked or cantilever for a yard with a slope?
Cantilever, where the ground falls across the opening or drains cross the gate line. A tracked leaf needs a level rail and clear drainage, and frost or leaves in the rail can stop it.
Which LPS 1175 class fits a sliding gate?
The risk assessment for the entrance decides it. SR1 to SR3 is the usual range for depots and campuses, and a higher class applies where vehicle attack is a named threat.
Does a sliding gate in the New Town need planning permission?
It may, where the site is listed, sits in a conservation area, or the gate faces the highway. Check the position, the height and the listing grade with the City of Edinburgh Council before ordering.
How does a sliding gate job move from survey to handover?
Drawings and the ratings for each gate come first, the surveyor tapes the opening and checks the ground fall, each gate follows the written specification, and dispatch honours the dates set when the survey was done. The first answer lands by the next working day, with a price figure and the specification in writing.
Need sliding vehicle gates for an Edinburgh depot, campus, hotel or yard? Send the opening width and the rating the gate must hold.
Other areas
Sliding vehicle gates in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.