Perimeter and HVM · PAS 68 and IWA 14-1
Sliding Vehicle Gates in Cambridge
Sliding vehicle gates for Cambridge depots, hospital yards, college sites and science park units, rated where the risk calls for it and built to the opening.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Cambridge
Get a free quote in Cambridge
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Cambridge
What we supply in Cambridge
A sliding gate moves to one side along the fence, instead of swinging out over the road or back across the yard. That sideways travel fits a wide vehicle opening where the fence gives room to one side and no room for a leaf to swing. Sliding vehicle gates work well at depots, hospital yards, college grounds and car parks, where vehicles come and go all day and the gate has to clear the way fast, then shut and lock behind them.
Cambridge has no shortage of such sites. Vans and lorries serve the units of the Cambridge Science Park through the day, the Cambridge Biomedical Campus runs service yards and staff car parks beside its buildings, Addenbrooke’s Hospital runs a busy yard of its own, the colleges of the University of Cambridge open onto narrow lanes where a swinging leaf would block the road, and Cambridge station moves taxis, buses and delivery vans through a tight forecourt. At those entrances, a sliding gate keeps the way clear for vehicles and leaves the yard behind it open for parking and loading.
ArxBridge supplies sliding vehicle gates for Cambridge buyers who want a vehicle entrance under control, with a rating where the risk calls for one, and made to the measurements of the opening it will guard. Gate, motor and access control are ordered together as one entrance, so nothing is added as an afterthought. The area page for the city, physical security in Cambridge, covers the wider picture.
Where a Cambridge site puts a sliding gate to work
The Science Park and the Biomedical Campus are the clearest case. Units there take vans and lorries through wide openings many times a day, and a leaf that swings across that opening would need a wide clear arc in the yard. A sliding gate travels beside the fence instead, so the yard keeps all its area for loading and parking. The lead times and programme risks guide shows how a rated gate is planned around the build programme, so the opening is ready on arrival.
The colleges bring a different pattern. Grounds beside the River Cam and lanes near King’s College Chapel leave little room for a leaf to swing, and a gate at a college entrance must open for morning deliveries, shut through the day and open again for service vehicles, without reaching across a pavement where people walk. Cambridge station brings the same pressure at a larger scale, with taxis and buses moving through the forecourt all day. For both, the sliding action is what matters: the gate stays clear of the space people use.
At Addenbrooke’s Hospital and across the Biomedical Campus, delivery vehicles, waste collection and porters pass through one gate, while staff and visitors use the main entrances. Keeping the service gate separate from the staff car park gate lets each run on its own access control. The hostile vehicle mitigation page shows how a gate sits beside bollards and barriers where a vehicle route runs close to a building.
Tracked or cantilever for a Cambridge opening
A tracked gate runs on wheels along a rail fixed into the ground across the opening, while a cantilever gate is carried by rollers on a post, so nothing crosses the ground at the opening. Uneven ground, a slope, a drain or a crossing all point to the cantilever build, and a flat yard on firm ground takes a tracked gate well. The gate automation guide shows how the drive and the controls fit the gate type.
Each Cambridge site is matched to its build in the table below, with the rating and the automation point for that site.
| Cambridge site | Gate build | Rating | Automation point |
|---|---|---|---|
| Science Park units beside the A14 | Cantilever, wide opening | SR2 or SR3 | Fast motor for van and lorry flow |
| Biomedical Campus service yards | Tracked gate on level ground | SR2 | Access control set to delivery hours |
| College grounds near the River Cam | Cantilever, uneven ground | SR2 | Intercom and card reader |
| Cambridge station forecourt | Tracked, short opening | SR1 or SR2 | Timed opening for taxis and buses |
Ratings and standards for a Cambridge gate
Where a Cambridge gate must resist forced entry, the rating comes from the LPS 1175 standard. A class is never fixed until LPS 1175 Issue 8.2 (September 2024) must be checked against the risk at the entrance, because the class follows the value held behind the gate and the tools an intruder might carry. The scale runs SR1 to SR5.
Where a gate leaf also needs fire resistance, the choice between BS EN 1634-1:2014+A1:2018 can be settled only by test evidence that covers the leaf, the frame and the hardware together. The fire ratings page carries the classes, and a leaf with a fire rating needs its seals and fixings checked as part of that rating.
Stopping a vehicle calls for a different rating from resisting forced entry. A gate on a vehicle route that must hold against impact is specified to ISO 22343-1:2023, and the classes now in force sit on the vehicle impact ratings page. The old PAS 68:2013 standard no longer stands, after its withdrawal on 25 October 2023. Where the risk is a person with tools rather than a vehicle, the forced entry class is the right rating, and the hostile vehicle mitigation page shows how gates, bollards and barriers share the work at a vehicle entrance.
Forced entry and vehicle impact are two different jobs for one gate. Name the rating that matches the real threat, or the gate will be measured against a test it was never built to pass.
Automation, access control and safety
Most sliding gates are powered, so motor, access control and safety devices sit in the same specification as the gate leaf. Entry can be controlled by card, keypad, intercom or timed schedule, and the choice follows the people who use the gate and the hours they use it. A depot gate in daily use needs a fast motor and a reader placed where a lorry driver can use it from the cab, while a college gate needs timed opening and an intercom for visitors. Safety is not an extra on a powered gate: force limitation, safety edges and photocells halt the gate if a person or a vehicle stands in its path, and those devices belong in the specification beside the gate and the rating. When a gate closes on a vehicle or a pedestrian, the specification has failed, not the motor. After handover, the keeping a rating valid guide lists the routine checks.
From survey to fitted gate in Cambridge
Every job opens with a survey: width and height, fence line and ground, run back room along the fence, and power and drainage at the threshold. The written specification follows, naming gate build and SR class where one applies, with vehicle impact class where one applies, and the motor, access control and safety kit. The design service turns the survey into that specification, and the acceptance and snagging guide lists the checks at handover.
Once the survey is done, the gate is built to those measurements. Fitting takes place on site under the installation service. For a Cambridge order, send the opening width and a photograph of the fence to [email protected] by email. A written specification and a budget range arrive within one working day. See the wider gate range on the security gates page.
Questions about sliding vehicle gates in Cambridge
Sliding gate or swing gate for a Cambridge yard?
Choose the sliding gate where the opening is wide and the fence line gives run back room, and choose the swing gate where the yard has a clear arc and the opening is narrow. The survey measures the run back first, because that measurement settles the choice.
What rating should a Science Park gate carry?
The rating follows what sits behind the gate and how the entrance is used. Units on the Science Park often ask for SR2 or SR3 against forced entry, and a vehicle impact class to ISO 22343-1:2023 where a vehicle is a real threat.
Does a sliding gate in Cambridge need planning permission?
Permission can be needed where the gate faces a public road or stands in a conservation area, and the height of the gate and its position on the boundary both count. Cambridge has wide conservation areas around the colleges and the city centre, so the planning position is settled during the survey, ahead of the specification.
What keeps a sliding gate running after fitting?
Check the track or the rollers, the motor and the safety devices on a set round, and keep the run back clear of leaves, grit and parked vehicles. The maintenance service covers those visits, and the first one can be booked when the gate is handed over.
Planning a sliding vehicle gate for a Cambridge site?
Send the width of the opening, the run back along the fence and photographs of the ground, and a specification for gate, motor and safety devices follows. Contact ArxBridge to start.
Other areas
Sliding vehicle gates in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.