Sliding Vehicle Gates in London

Sliding vehicle gates for London depots, hospitals, campuses and car parks: tracked or cantilever, LPS 1175 rated, automated and built to your opening.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in London
Prefer to talk?+44 7352 267239

Get a free quote in London

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in London

What we supply in London

More on this

A wide vehicle entrance with open fence line beside it often suits a leaf that slides sideways. Nothing arcs over the road, and nothing sweeps back across the yard, so the entrance stays clear for the next vehicle. Sliding vehicle gates serve car parks, campuses, depots and hospital service yards, where the gate opens again and again through the day and must shut firmly between vehicles.

London offers that gate a great deal of work. Yards and warehouses cluster in Park Royal, Barking, Dagenham, Enfield and Croydon, beside the North Circular, the A13 and the M25. Guy’s, St Thomas’ and St Mary’s run service yards for deliveries, waste collection and porters, while the universities of Bloomsbury, South Kensington and the City run campuses where staff cars, delivery vans and service vehicles share few entrances. A sliding leaf at those entrances keeps the opening clear and leaves room behind it for parking and loading.

London buyers get their sliding vehicle gates from ArxBridge, with an entrance that is controlled, graded where risk calls for it, and made to fit the opening. Gate, motor and access control are specified as one entrance, not as separate parts. For the wider city picture, see our page on physical security in London, and for the doors guarding the buildings behind the gate, see security doors in London.

LeafSlides sideways along the fence
WidthMade to the measured opening
DriveMotor with safety edges and photocells
GradesSR1 to SR5, plus vehicle impact class

London entrances that fit a sliding leaf

Logistics yards make the strongest case. A Park Royal or Barking depot moves lorries through a broad opening all day, and a swinging leaf there would eat a large empty arc inside the yard. A leaf that slides along the fence leaves the yard free for loading and parking instead. Gate choice by vehicle flow and opening hours is covered in the warehouse security gates guide.

Hospitals and universities use the gate to keep traffic apart. At the large London hospitals, porters, waste collection and deliveries use one service entrance, staff and visitors use the main entrance, and the sliding gate holds the service side apart. A second gate at the staff car park can work on access control by itself. The hospital security gates guide covers gate placement that keeps service traffic out of patient areas.

Schools, housing estates and city centre car parks work at a smaller scale on the same idea. A school gate opens for the morning drop off, closes during the day and opens again for deliveries, without a leaf swinging over a pavement where children walk. An estate gate lets residents through at all hours and keeps parking closed at night, while a West End or City car park gate clears its entrance fast at peak times. Each time, the leaf stays out of the space people use.

Reading the ground: track or cantilever

Two forms cover most London entrances, and ground levels choose between them. A tracked leaf runs on wheels in a rail let into the ground, which suits a level yard on a firm base. A cantilever leaf hangs from rollers on posts with no rail, which fits a yard where the ground slopes, where a drain crosses the entrance, or where grit and leaves would clog a track. Check levels before choosing, because the wrong form wears fast and jams often. How drive and controls are matched to the leaf, and why the motor must suit leaf weight and daily cycles, is explained in the gate automation guide.

The table below matches London sites to the form that usually fits, with the grade and the control point for each site.

London site Form Grade Control
Depots in Park Royal and Barking Cantilever, broad leaf SR2 or SR3 Quick motor, lorry flow
Cargo yards near Heathrow Cantilever, broad leaf SR2 or SR3 Plate reader
Hospital service yards Tracked, level base SR2 Timed delivery access
University campuses Cantilever, uneven base SR2 Intercom plus card reader
Schools, estates, central car parks Tracked, short leaf SR1 or SR2 Timed opening
Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Grades for forced entry and for impact

Tool resistance is graded from SR1 to SR5. The September 2024 issue of LPS 1175 sets that scale, and the grade tests leaf, posts, rollers or track, and lock together as one gate, so a strong leaf held by weak posts gains nothing. How the grade is read against a gate is explained in the LPS 1175 gates and grilles guide. Grade should follow risk at that entrance: a depot holding valuable stock needs more than a staff car park. Record the reason in the specification.

Stopping a vehicle is tested apart from resisting tools. Where the gate must stop a vehicle, ISO 22343-1:2023 belongs in the specification, with the classes now in force listed on the vehicle impact ratings page. PAS 68:2013 ended on 25 October 2023, so no new gate should be specified to it. Where an impact grade is needed, and where a forced entry grade alone is enough, is set out in the anti-ram gates and barriers guide, since the two threats need different steelwork, posts and foundations.

Tool resistance and vehicle stopping are different tests. Name the grade that matches the threat the gate will face, and write that threat into the specification.

Power, control and keeping people safe

Most London sliding gates are powered, and motor, access control and safety devices belong in one specification with the leaf. Control may use a clock schedule, an intercom, a keypad or a card reader, chosen by the users and their hours. A depot gate open all day needs a fast motor, with the reader mounted so a driver in a lorry cab can reach it without stepping down. A school gate needs timed opening.

Safety devices form part of the gate, not an extra. Force limits, safety edges and photocells halt the leaf when a person or vehicle stands in its path, and the duties for a powered gate are set out in the powered gates safety duties guide. A leaf that shuts on a vehicle or a pedestrian points to a fault in the specification, not in the motor, so name each safety device in the specification itself, beside the gate and its grade. When a London gate by a highway or in a conservation area needs permission is also set out in the guide to planning permission for shutters, gates and bollards.

How a London order runs

Work begins at the entrance. The survey records opening width and height, ground and fence line, run back room the leaf needs along the fence, plus power supply and drainage at the threshold. Next is the written specification, naming gate form, LPS 1175 grade where one applies, vehicle impact class where one applies, motor, access control and safety devices. What moves the price, from leaf width and groundwork to motor size and integration with existing systems, is shown in the security gates cost factors guide.

To order in London, send the width and height of the opening, with a photograph of the fence line, by email to [email protected]. Expect a budget range and a written specification back within one working day. The wider gate range is on the security gates page.

Frequently asked questions

Sliding leaf or swinging leaf for a London yard?

Pick a sliding leaf where the opening is wide and fence line room exists, but no room exists for a leaf to swing. Where the opening is narrow and a clear arc sits behind the gate, a swinging leaf can work. Measure run back room along the fence first, since that measurement usually settles the choice on a tight London site.

What grade fits a Park Royal depot gate?

Grade follows the risk at that entrance. Many depots ask for SR2 or SR3 under LPS 1175 against forced entry, plus an ISO 22343-1:2023 vehicle impact class where a vehicle attack is a live risk.

Will a London sliding gate need planning permission?

It may, where the gate stands by a highway or inside a conservation area, with height and position both counting. Planning rules are checked during the survey, before the specification is written, so the gate is not ordered before the permission question is answered.

How is a sliding gate kept running after fitting?

Through regular checks on track or rollers, motor, safety edges and photocells, plus keeping the run back area clear so nothing blocks the leaf. The checks are set out in the in-service care guide, and the first maintenance visit can be booked at handover.

Need a sliding vehicle gate for a London site?

Send the width and height of the opening, plus a photograph of the fence line and ground, and a specification for the gate, motor and safety devices follows. Get a free quote and start the order.

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.