Certified physical security

ArxBridge
Steel security bollards with amber bands outside a UK office entrance at dusk

Perimeter and HVM · PAS 68 and IWA 14-1

Sliding Vehicle Gates in Wolverhampton

Sliding vehicle gates for Wolverhampton yards, depots and factories: LPS 1175 rated gates with automation, safety devices and a written specification.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Wolverhampton
Prefer to talk?+44 7352 267239

Get a free quote in Wolverhampton

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Wolverhampton

What we supply in Wolverhampton

More on this

A Wolverhampton yard that takes lorries all day needs an entrance that opens wide, closes firmly and never blocks the road outside. A sliding vehicle gate does that job by running back along the fence line, so the full width of the entrance stays clear for the vehicle passing through, and no leaf swings out onto the pavement or into the yard. For a wide entrance with room beside it, it is the most practical gate form there is.

The city gives the sliding gate plenty of ground to cover. Factories, workshops and distribution units sit on the estates at Pendeford, Bilston and Wednesfield, with wide yard entrances, while the i54 site by the M54 at Junction 2 holds large manufacturing and logistics units that take articulated vehicles. Builders merchants, waste and recycling yards, and depots near the A449 and the ring road all run the same pattern: a stream of vehicles in and out, a fence line that must stay closed between visits, and a gate that must open fast enough to keep traffic off the public road.

The choice of sliding gate starts with the ground, not the leaf. A tracked gate runs on a rail set into the ground, which fits a level yard with a firm base. A cantilever gate hangs from rollers on posts and needs no track, which fits a yard where the ground is uneven, or where grit, snow and standing water would clog a rail. The security gates range holds both forms, and the survey should settle which one the ground allows before any leaf is ordered.

Gate formTracked or cantilever sliding gate
RatingLPS 1175 SR2 or SR3
ControlIntercom, fob or number plate reader
Reply timeOne working day

How the yard decides the gate form

Three measurements decide the form. First, the clear width of the entrance, because the leaf must cover it with room for the posts and the lock. Second, the run back, because a sliding leaf needs a clear stretch of fence at least as long as the leaf itself, with no gate post, sign or parked vehicle in its path. Third, the ground levels across the entrance, because a tracked gate needs a level rail and a cantilever gate needs firm posts that can carry the leaf without sag. A yard that fails the run back test cannot use a sliding gate at all, and the survey should say so before the foundation is dug.

Vehicle flow decides the automation. A yard with a steady stream of lorries needs a motor sized for the leaf weight and the number of cycles each day, with an opening speed that keeps queues off the road. A yard with occasional visitors can use a slower motor and an intercom, while a depot with regular hauliers can use fobs or a number plate reader so known vehicles pass without a phone call. The gate automation guide lists the safety devices a powered gate should carry, and the automatic gates cost factors guide explains what sets the price.

Yard in Wolverhampton Gate form Control that fits Rating to ask for
Distribution unit near the M54 Cantilever sliding gate Number plate reader LPS 1175 SR2
Factory yard in Bilston Tracked sliding gate Fob reader and intercom LPS 1175 SR2
Builders merchant yard Tracked sliding gate Intercom and keypad LPS 1175 SR2
Depot with a high threat profile Cantilever sliding gate with barrier Card reader and intercom LPS 1175 SR3
School or hospital service yard Sliding gate with pedestrian gate Timed opening and intercom LPS 1175 SR2

Ratings that a sliding gate should carry

Forced entry resistance for a gate is graded under LPS 1175 Issue 8.2, which rates gates and grilles from SR1 to SR5 against the tool set and attack time named in the standard. The rating covers the leaf, the posts, the rollers or track, and the lock as one gate, so a strong leaf on weak posts earns nothing. The gates and grilles guide under LPS 1175 shows how the classes read against a gate, and the guide to SR2, SR3 and SR4 explains when SR3 is worth the extra cost over SR2. Most Wolverhampton yards sit at SR2, while a site guarding high value stock or a control room may justify SR3.

Vehicle impact is a separate rating for gates that face a ramming risk. The standard in force is ISO 22343-1:2023, and the vehicle impact ratings page gives the scale. In October 2023 PAS 68:2013 was withdrawn, so ask for the ISO 22343-1 class instead, with the speed, the vehicle weight and the penetration distance recorded in the same document. Where a gate alone cannot carry the vehicle rating, security bollards or rising bollards set beside the gate block the route a vehicle could use to get around it.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Safety devices and access control

A powered sliding gate must stop on meeting a person or a vehicle. Safety edges on the leading edge, photocells across the entrance and a force limit on the motor do that work, and the controls must fail safe, so a power cut still leaves people a clear way out where they need one. The guide to powered doors, gates and barriers safety duties sets out the duties that apply to a powered gate, and the specification should name each safety device rather than leaving it to the installer to choose on the day.

Access control should match the people who use the gate. A pedestrian gate of its own, set beside the vehicle lane, keeps people on foot away from lorries, and the warehouse security gates guide shows how a busy yard plans the two lanes together. Card readers, fobs, intercoms and plate readers each fit a different flow of users, and the choice should be written into the specification with the motor and the safety devices.

Check the run back before you choose a sliding gate. A leaf with no clear stretch of fence to slide into is a gate that cannot open, and no motor can fix a yard that has no room for it.

Project steps for a sliding gate in Wolverhampton

Work starts at the entrance, with a survey of where the gate will stand. The surveyor records the opening width, the ground levels, the room for the leaf to run back, the power supply, the drainage, and whether planning rules limit the height, or limit a gate beside a public highway. The planning permission guide for shutters, gates and bollards sets out when a gate needs permission, and the survey should look at the local rules before the specification is settled. Photos and a boundary sketch give the specification solid ground to stand on.

The rating and the gate form are then written down for that entrance: leaf size, infill, automation, access control, and the SR class or the ISO 22343-1 vehicle rating. The gate, bollard and barrier forms in the perimeter range are what the record draws on, and the proof for the rated gate is passed to the buyer with it, so the buyer can check the claimed class against the class the gate was actually tested to. Groundwork comes before the leaf: foundations first, then ducts for power and data, and drainage set to the surveyed levels. For other entrances on the same Wolverhampton site, the page on security doors in Wolverhampton covers the doors that guard the building itself. Send the entrance drawings and the rating the gate needs to [email protected] by email. Expect a reply within one working day.

Frequently asked questions

How much run back does a sliding gate need in a Wolverhampton yard?

At least the full width of the leaf, clear of posts, signs, bins and parked vehicles, along the fence line. A tracked gate also needs a level rail across the whole run, while a cantilever gate needs firm posts that can carry the leaf. The survey measures the run back before the gate form is chosen.

Should a yard choose a tracked gate or a cantilever gate?

The ground decides. A tracked gate fits a level yard with a firm base and a clear rail. A cantilever gate fits uneven ground, or a yard where grit, water and debris would clog a track. A yard with no run back room cannot use either form, and a swing gate or a barrier may fit better.

What happens to a powered sliding gate if the power fails?

A powered gate needs a hand release that staff can work, and controls that fail safe so people can get off the site. The specification should state how the release works and what the fail safe state is, and staff should see the release used at handover.

Does a sliding gate in Wolverhampton need planning permission?

A gate beside a highway that stands above a set height may need permission. Whether it needs permission turns on the height of the gate, where it stands, and whether the site is listed, or lies in a conservation area. A listed building needs consent before its boundary is changed. The survey looks at the local rules before the specification is settled.

Planning a sliding vehicle gate for a Wolverhampton yard?

Send the entrance sketch, the clear width and the rating the gate needs. We reply within one working day, sending a written specification and a survey visit date. Contact ArxBridge to start.

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.