Certified physical security

ArxBridge
Waterfront offices with glass entrances and bollards in Cardiff

Perimeter and HVM · PAS 68 and IWA 14-1

Sliding vehicle gates in Cardiff

Sliding vehicle gates in Cardiff for depots, hospitals, campuses and service yards, with leaf, track, drive and safety set out for each entrance.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Cardiff
Prefer to talk?+44 7352 267239

Get a free quote in Cardiff

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Cardiff

What we supply in Cardiff

More on this

A sliding vehicle gates order for Cardiff gives a yard, depot or service entrance a leaf that runs sideways on a track instead of swinging out into the road, so the entrance stays clear for traffic while the gate is moving. The leaf, the track, the rollers and the drive are sized together from the measured width, the slope of the ground and the vehicles that will pass through, and the gate only runs true when the track bed is level and the run-back beside the opening is kept clear. A security gates in Cardiff page covers the wider gate range, while this page covers the sliding leaf alone.

Cardiff gives that gate a wide range of entrances. Depots and yards round Cardiff Bay hold service gates that open for lorries through the working day, the University Hospital of Wales holds a service yard gate for deliveries and waste vehicles, Cardiff University holds campus gates that separate teaching areas from service roads, and the Principality Stadium holds service entrances that open for event traffic and then shut again. Cardiff Airport holds airside and landside gates, Cardiff Central station holds yard gates behind the public areas, Queen Street and the St David’s Centre hold service gates behind retail units, and Cardiff Castle and City Hall hold yard gates that sit beside older walls. Physical security in Cardiff covers the wider city picture, and a sliding gate follows the entrance, not the postcode.

Sideways runLeaf slides along the track, so no swing space is needed in the road
Sized to the openingLeaf, track, rollers and drive sized from the measured width and ground fall
Rated where neededLeaf, frame and lock judged against the SR scale where a rating is named
Written recordOpening width, drive type and safety devices listed before fitting

How a sliding gate works at a Cardiff entrance

The rating schedule expects LPS 1175 Issue 8.2 (September 2024) defining the SR scale that a gate leaf, frame and lock are judged against. SR1 means one minute against tool set A1, SR2 three minutes against tool set B3, SR3 five minutes against tool set C5 and SR4 ten minutes against tool set D10. Each part is tested to the rating written in the specification, so a sturdy leaf set in a flimsy frame fails, and a sound lock fixed to a frame that bends fails as well. The LPS 1175 page gives the full scale, and the rating named on the order is the rating the gate must meet on site.

The leaf runs on rollers along a track set into the ground, or hangs from a cantilever frame where a ground track cannot be kept clear, and the choice is made from the ground, the traffic and the way the entrance is used. A tracked gate needs a level bed and a track that stays free of stone and grit, while a cantilever gate needs a firm frame and a counterbalance that holds the leaf true through its full travel. The automatic gates cost factors page explains what shapes the price of the leaf, the track and the drive, and the anti-ram gates and barriers walkthrough looks at what happens where the gate must also hold back a vehicle.

Choosing the leaf, track and drive

The leaf is chosen from the opening width, the height and the wind load on the site, with a solid leaf giving privacy and a barred leaf letting staff see through the entrance. The drive follows the leaf weight and the opening rhythm, with a light duty motor for a gate used now and then set against a heavy duty motor for a depot gate worked every few minutes. The vehicle impact ratings page gives the ratings that apply where a vehicle impact is part of the risk, and the due diligence for vehicle security barriers guide lists the checks a buyer should run before the order is placed.

Where the gate forms part of a hostile vehicle mitigation line, the gaps beside the leaf matter as much as the leaf itself. ProtectUK guidance caps the clear gap beside the line at 1,200 mm and sets the lowest height at 500 mm for the line, so a person cannot slip through beside the gate and a vehicle cannot pass under it, and an impact rating under ISO 22343-1:2023, for instance V/7500[N3]/80/90:0/0, is one rating that names the vehicle, the speed and the distance the vehicle moved past the line. The hostile vehicle mitigation page looks at the wider line, and the gate is only one part of it.

Fitting and upkeep through the year

Fitting starts with the ground, and the track bed is dug, levelled and set before the leaf is hung. The surveyor measures the opening width, the ground fall across the run and the clear run-back beside the opening, so the leaf that arrives parks fully clear of the entrance when it is open. The writing an operational requirement guide covers the list the site should agree before fitting starts.

Upkeep is mostly cleaning and checking. The track is swept clear of stone and grit, the rollers are checked for wear, the safety edges and photocells are tested, and the drive is checked for the force it applies when the leaf meets an obstruction. A leaf that drags, a roller that grinds or a safety edge that no longer stops the leaf is put right before the next check, so the gate keeps running true through wet months and dry months alike. The Romford premises: Saffron Road, Romford, Essex RM5 3ES. Phone the office during working hours. The programming a security door and barrier package guide covers how the gate, the access control and the barriers are timed together.

Entrance Leaf Drive Check on site
Depot yard Solid steel leaf Frequent use motor Track, rollers and safety edges
Hospital service yard Barred leaf Standard motor Photocells, lock and track bed
Campus service road Barred leaf Standard motor Run-back clear and rollers
Stadium service entrance Solid steel leaf Frequent use motor Lock, drive force and safety edges

A sliding gate is only as true as its track. When the track bed sinks or grit builds up in the rail, the leaf drags and the rollers wear fast, so the bed is levelled before fitting, and the rail is swept clear at each visit before the rollers are checked.

Questions about sliding vehicle gates in Cardiff

Does a sliding gate need a level track run?

Yes, the track bed is levelled before the leaf is hung, and the ground fall across the run is measured at the survey. A bed that sinks or a rail that fills with grit makes the leaf drag and wears the rollers fast, so the track is swept clear at each visit and the level is checked again where the ground has moved.

What happens when the power fails?

The drive has a manual release, and staff can shift the leaf without power once the release is shown to the site team at handover, so the gate can be opened and shut without power. The release position and the way it is used are written on the handover sheet, and the gate is tested by hand at each visit to confirm the release still works.

Will a sliding gate hold back a vehicle that hits it?

Only where the gate has been tested to an impact rating and the rating is named in the specification, such as a rating under ISO 22343-1:2023. A standard sliding gate holds back people and slows entry, but it is not an impact rated barrier, so the risk assessment names the rating where a vehicle impact is part of the risk.

How wide must the run-back beside the opening be?

The leaf parks beside the opening when it is open, so the run-back needs the full width of the leaf kept clear of bins, parking and planting. The survey measures the run-back at the same visit as the opening width, and the gate is only ordered where the clear run-back matches the leaf that will be fitted.

Send the entrance width, the ground fall and the vehicle types to [email protected] while the survey is under way, and the reply that comes back within one working day gives the leaf size, the drive and the price.

Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.