Perimeter and HVM · PAS 68 and IWA 14-1
Sliding Vehicle Gates in Nottingham
Sliding vehicle gates for Nottingham depots, hospitals, campuses and car parks: tracked or cantilever, rated and automated, built to your opening.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Nottingham
Get a free quote in Nottingham
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Nottingham
What we supply in Nottingham
A sliding vehicle gate moves sideways along the fence line instead of swinging out into the road or back into the yard. That one difference decides where it fits: a wide vehicle opening on a site that has room along the fence but no room for a gate leaf to swing. Sliding vehicle gates suit depots, hospital service yards, university campuses and car parks, where vehicles pass through all day and the gate must clear the opening fast, then close and lock behind them.
Nottingham has plenty of those sites. Warehouses and distribution yards sit beside the A52 and the M1, the two large hospitals run service yards, the two universities run campuses with vehicle entrances that mix staff cars, delivery vans and service vehicles, and the city centre holds car parks and service areas where a swinging gate would block the pavement or the yard. A sliding gate at those entrances keeps the opening clear for vehicles and leaves the space behind the gate free for parking or loading.
ArxBridge supplies sliding vehicle gates for Nottingham buyers who need a vehicle entrance that is controlled, rated where the risk calls for it, and built to the opening it will serve. The gate is specified alongside its automation and access control, so the whole entrance works as one system, not as a gate with a motor added later. Our page on physical security in Nottingham gives the wider picture for the city.
Where a sliding gate suits a Nottingham site
Logistics yards are the clearest case. A depot beside the A52 or the M1 takes lorries through a wide opening many times a day, and a swinging leaf across that opening would need a large clear arc inside the yard. A sliding gate runs along the fence instead, so the yard keeps its full area for loading and parking. The warehouse security gates guide sets out how gate choice follows the vehicles that use the yard and the hours they run.
Hospital and university sites bring a different pattern. Service yards at the two large hospitals take delivery vehicles, waste collection and porters through one gate, while the main entrances take staff and visitors. A sliding gate at the service yard keeps those flows apart, and a second gate at a staff car park can run on access control alone. The hospital security gates guide explains how gates are placed so that service traffic never passes through a patient area.
Schools, colleges and city centre car parks use the same logic at a smaller scale. A school gate must open for the morning drop off, close during the day and open again for deliveries, without a leaf swinging across a pavement where children walk. A car park gate must clear the entrance quickly at peak times and lock at night. In both cases the sliding action is the point: the gate never reaches into the space people use.
Cantilever or tracked: choosing the build
A tracked gate moves on wheels along a rail set into the ground across the opening. A cantilever gate hangs from rollers on a post and needs no rail across the opening, which suits ground that is uneven or that must stay clear for vehicles. The choice follows the site: a level yard with a firm surface takes a tracked gate well, while a yard with a slope, a drain or a crossing point often suits a cantilever gate better. The gate automation guide explains how the drive and the controls are matched to the gate type.
The table below sets out the Nottingham sites where each build is most often the right answer, and the rating and automation point for each one.
| Nottingham site | Gate build | Rating | Automation point |
|---|---|---|---|
| Logistics yards beside the A52 and M1 | Cantilever, wide opening | LPS 1175 SR2 or SR3 | Fast motor for lorry flow |
| Hospital service yards | Tracked, level ground | LPS 1175 SR2 | Access control for delivery times |
| University campuses | Cantilever, uneven ground | LPS 1175 SR2 | Intercom and card reader |
| Schools and colleges | Tracked, short opening | LPS 1175 SR1 or SR2 | Timed opening for drop off |
| City centre car parks | Cantilever, no ground rail | LPS 1175 SR2 | Ticket or card entry |
Ratings and standards for vehicle gates
A gate that is meant to resist forced entry is rated under LPS 1175. Issue 8.2 was published in September 2024, and ratings run SR1 to SR5. The LPS 1175 gates and grilles guide explains how the rating applies to a gate leaf, its frame and its locking. The rating follows the risk at that entrance: a depot holding high value stock needs a higher rating than a staff car park, and the specification should say why.
Vehicle impact is a separate rating. Where a gate must stop a vehicle, name ISO 22343-1:2023 in the specification. The vehicle impact ratings page lists the classes in force. PAS 68:2013 is withdrawn, so a new gate should never be specified to PAS 68. The ISO 22343 vehicle barriers guide explains the current classes, and the anti-ram gates and barriers guide sets out where an impact rated gate is needed and where a forced entry rating is enough.
A gate that resists a crowbar is not the same as a gate that stops a vehicle. Name the right rating for the threat the gate actually faces, or the gate will be tested by the wrong one.
Automation, access control and safety
A sliding gate is usually powered, and the motor, the access control and the safety devices belong in the same specification as the gate. Access control can be a card reader, a keypad, an intercom or a timed schedule, and the choice follows who uses the gate and when. A depot gate that runs all day needs a fast motor and a reader that lorry drivers can reach from the cab, while a school gate needs timed opening.
Safety is not optional on a powered gate. The powered gates safety duties guide sets out the duties that apply, including force limitation, safety edges and photocells that stop the gate when a person or a vehicle is in its path. A gate that closes on a vehicle or a pedestrian is a failure of the specification, not of the motor, so the safety devices should be named in the same document as the gate and the rating.
From survey to fitted gate in Nottingham
The work starts with a survey of the opening: the width and the height, the ground and the fence line, the run back space the gate needs along the fence, and the power supply and the drainage at the threshold. Then comes the written specification, naming the gate build, the LPS 1175 rating where one applies, the vehicle impact class where one applies, the motor, the access control and the safety devices. The in-service care guide explains the checks that keep a gate running after handover, and the security gates cost factors guide shows what moves the price.
Manufacture follows the survey, and the gate is built to the measured opening. Then comes handover, with the keys, the access details, the test records and the care notes in one pack. For a Nottingham order, send the opening sizes and photographs of the fence line to [email protected]. A budget range and a written specification come back within one working day. For the wider gate range, see security gates.
Frequently asked questions
Should my Nottingham yard have a sliding gate or a swing gate?
A sliding gate suits a wide opening where there is room along the fence but no room for a leaf to swing. If the yard has a clear arc behind the gate and the opening is narrow, a swing gate can work. The survey should measure the run back space along the fence first, because that decides the answer.
What rating should a depot gate in Nottingham carry?
It follows the risk at that entrance and the value held behind it. Many depots ask for LPS 1175 SR2 or SR3 for forced entry, plus a vehicle impact class under ISO 22343-1:2023 where a vehicle attack is a real risk.
Does a sliding gate need planning permission in Nottingham?
It can do, where the gate fronts a highway or sits in a conservation area, and height and position both matter. The planning rules are checked as part of the survey, before the specification is written.
What keeps a sliding gate running after it is fitted?
Regular checks on the track or rollers, the motor, the safety edges and the photocells, plus cleaning of the run back area so nothing blocks the gate. The in-service care guide linked above sets out the checks, and a maintenance visit can be arranged at handover.
Planning a sliding vehicle gate for a Nottingham site?
Send the opening sizes and photographs of the fence line and the ground, and a specification comes back for the gate, the motor and the safety devices. Contact ArxBridge to start.
Other areas
Sliding vehicle gates in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.