Certified physical security

ArxBridge
Industrial brick buildings with navy steel doors in Sheffield

Fire · EI 30 to EI 120

Fire Rated Steel Doors in Sheffield

Fire rated steel doors for Sheffield hospitals, universities, shops and stadiums, built to the fire test standard with evidence and a reply in one working day.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Sheffield
Prefer to talk?+44 7352 267239

Get a free quote in Sheffield

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Sheffield

What we supply in Sheffield

More on this

Sheffield turns to fire rated steel doors where a plant room, a stair core, a service riser or a corridor must hold fire and smoke back for a stated time. Wards at the Royal Hallamshire Hospital and the Northern General Hospital, lecture halls at the University of Sheffield and Sheffield Hallam University, the shops of Meadowhall, the stands of Bramall Lane and Hillsborough, and the workshops of Kelham Island and Attercliffe all keep doors on escape routes and compartment lines. Fire rated steel doors protect those lines across the city.

Each building’s use fixes where its doors go. Wards, theatres and pharmacy stores at the two main hospitals need doors that shut, latch and seal when the alarm sounds, and so do lecture halls and laboratories at the two universities, classrooms and halls in schools around the suburbs and the concourses at Sheffield station. That building’s fire strategy fixes the rating at every opening, with leaf, frame, seals and hardware counting as one tested doorset built to that rating. Rated work in other parts of the city is covered at physical security in Sheffield.

HospitalsNorthern General, Royal Hallamshire
UniversitiesUniversity of Sheffield, Sheffield Hallam
Shops and stadiumsMeadowhall, Bramall Lane, Hillsborough
Workshops and industryKelham Island, Attercliffe units

Which Sheffield buildings ask for these doors first

In offices and civic buildings, stair cores and risers usually take the longest ratings. The offices of the city centre and St Pauls Place, the Winter Garden and the Millennium Gallery quarter and hotels near Sheffield station all have doors on escape routes used by staff and members of the public. Each opening needs a fire rating to match the compartment wall around the opening, as the fire door regulations for offices guide shows how an office schedule deals with escape doors, risers and plant rooms.

Hospitals and universities bring their own mix. Plant rooms, wards, operating theatres and pharmacies at the Royal Hallamshire Hospital and the Northern General Hospital follow one estate plan. Teaching halls, student blocks and laboratories across the University of Sheffield and Sheffield Hallam University spread over campuses in the city centre and at Collegiate Crescent. The fire strategy for the floor sets the class for a laboratory door, a drug store door or a ward door. The fire door regulations for hospitals guide shows how a hospital schedule covers wards, theatres and departments.

Shops, stadiums and workshops form the third group. The shops at Meadowhall, the stands and concourses at Bramall Lane and Hillsborough Stadium, the arena and the workshops of Kelham Island and Attercliffe all hold crowds or shift workers through the day. Their escape doors must stay closed in a fire but open freely when people leave during an evacuation. The fire door regulations for warehouses guide covers a warehouse schedule for stores, loading bays and escape stairs.

How a steel door earns its fire rating

The rating sits with the complete doorset alone, never with the leaf by itself. Hinges, closer, frame, leaf, intumescent seals and locks were tested as one set together, so swapping a part after that test leaves the rating with no backing. Each part belongs in the specification with the test proof that backs it.

A steel door carries a fire resistance class from 30 minutes to 120 minutes. E means integrity, so flames and hot gases stay on the fire side; EW puts a cap on radiated heat; EI adds insulation, keeping the face away from the fire cooler. E30 is a common fit for a corridor door. In a high block, a stair core or a riser may need EI60 or more. Each class, with its test basis, is explained on the fire ratings page.

Many Sheffield doors need two duties at once. A service door, a plant room door or a riser door may need a forced entry class beside a fire rating. The dual certification guide shows how one doorset can carry both. The specification draws LPS 1175 Issue 8.2 (September 2024) back to the SR2 class B3 entry, set on the same row as the fire class. The schedule draws BS EN 1634-1:2014+A1:2018 around the class for each opening, so the E, EW or EI letter stands next to its test record. A steel leaf and a timber leaf suit different openings, and the steel and timber comparison matches each material to the wear an opening sees.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Rating guide for Sheffield openings

Treat the table as a rough guide only, since the class for each opening is set by the building’s fire strategy, and that call comes before any price is put forward.

Place in Sheffield Opening Class to quote Door type
Station buildings and offices Service risers and stair cores EI60, or the strategy’s named class Steel doorset, fire rated
Hospitals and clinics Drug stores, theatres and wards EI30 to EI60, smoke seals included Steel door, fire rated, seals fitted
Universities and schools Halls, stair cores and laboratories E30 to EI60, as the strategy directs Steel door, fire rated, glazed where needed
Arena, stadiums and shops Escape doors and rear corridors E30 to EI60, panic hardware included Steel door, fire rated, panic hardware fitted
Workshops and plant rooms Stores, electrical rooms and boiler rooms EI60 or higher, as the strategy requires Solid steel door with a fire rating

Specifying a fire rated steel door in Sheffield

Take the fire strategy behind the door and the compartment line it sits on as the start for each opening. The E, EW or EI class follows from the wall rating and the room’s use. Each opening needs its points agreed before any price is quoted, and the specifying guide holds them. Evidence for the class quoted is covered by the fire door certification guide.

Put the leaf, frame, seals and hardware on one specification line together, with test proof for the class quoted alongside them. Add the vision panel, the access control interface, the finish and the threshold, so the fitted door holds its rating day after day. The plant room fire doors guide deals with the doors that take the hardest wear in a building.

A Sheffield door that must carry both classes at once, fire and forced entry, puts the two on one specification line. On the SR2 fire doors page, a door holds an SR2 class next to its fire class. The fire door gaps guide lists the gaps that keep a rated door working well after fitting.

Survey to fitted doorset in Sheffield

A Sheffield project starts with drawings and a door schedule that sets the class each opening needs, and the survey team then measures every opening on site, looking at the build of the wall, the level of the floor and the services running across the frame, and noting the closer, the lock and how often the door is used each day. The survey sets sizes and the fixing method, and every doorset is made for the opening that was surveyed.

Each doorset is built from the written specification, with the test evidence for the class quoted going with it. Fitting works to the drawings already issued, with fitting and handover handled by the installation service. Routine checks after handover are covered by the fire door maintenance guide.

[email protected] takes the rating for every opening and the drawings; the reply inside a single working day carries a checked class, a budget range and a written specification. The quote form takes those details too.

Doors, frames and hardware across Sheffield buildings

Start from the wall the door sits in, because a rating taken from another building rarely fits a Sheffield opening. The wall rating and the room’s use should travel with the enquiry, and both facts decide what the specification holds.

Questions about fire rated steel doors in Sheffield

Which fire rating suits a Sheffield stair core door?

It is decided by the building’s fire strategy. A stair core door often takes EI60 and a corridor door E30, with the rating of the wall the door sits in deciding between them.

Can a Sheffield fire door hold an SR2 class too?

Yes, if the doorset has passed a test for both duties. Put the fire class and the SR class on one line of the specification, with test proof behind each class.

Do Sheffield hospitals and stadiums need fire rated steel doors?

In hospitals, stadiums and shops, doors on stair cores, escape routes and back of house corridors often need a fire rating. Each building’s fire strategy sets the class.

What does a Sheffield quote need?

Drawings, the wall rating and the class for each opening are what a quote needs. Use the quote form to send them. A reply arrives inside a single working day, giving a written specification, a checked class and a budget range.

Want a fire rated steel door in Sheffield? Share drawings and the class for each opening. Every opening gets a tested doorset matched to it.

Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.