Fire · EI 30 to EI 120

Fire Rated Steel Doors in London

Fire rated steel doors in London, classes E, EW and EI from 30 to 120 minutes. Furnace tested, with intumescent seals and evidence for each door.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in London
Prefer to talk?+44 7352 267239

Get a free quote in London

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in London

What we supply in London

More on this

Fire rated steel doors in London sit at the openings where a fire must be held back while people leave and fire crews work. A stair core in a City tower, a lift lobby in a Canary Wharf block, a ward corridor at St Thomas’ Hospital and a plant room at Heathrow Airport all need a door that shuts firm on its closer and holds its class. Leaf, frame, seals and hardware are tested as one set, and the class names how long the door holds back flame.

London asks for those doors in very different buildings. Guy’s Hospital with St Mary’s Hospital fit them at wards, corridors and plant rooms. Lecture blocks, laboratories and student rooms at King’s College London, Imperial College London and UCL take them too. West End theatres and hotels fit them at auditoria, kitchens and service routes, the three stadiums at concourses and plant rooms, and City offices at stair cores and lift lobbies. Rated work elsewhere in the city is listed on the physical security in London page.

ClassesE, EW and EI forms, from 30 to 120 minutes
Leaf and frameSteel leaf with intumescent seals at each edge
Closer and hardwareNamed as tested with the leaf
PapersTest evidence naming the class for each opening

Where London buildings need fire rated steel doors

London hospitals put the heaviest demand on them. At Guy’s Hospital, St Mary’s Hospital and St Thomas’ Hospital, ward, corridor and plant room doors are opened and shut through the day while patients and equipment move past, so a closer that slips or a seal that wears can leave a fire door failing with no visible damage. The fire door regulations for hospitals guide sets out the use of fire doors in hospital buildings, and the inspection checklist sets out the checks for each door.

Universities, stadiums and the airport ask for a different spread. Lecture blocks, laboratories and student rooms at King’s College London, Imperial College London and UCL need clear escape routes for large numbers, concourses at the three stadiums need doors that hold their class while crowds move at set times, and terminals at Heathrow Airport need doors where public, staff and service routes cross. Rated steel doors at the stair cores and service routes keep those routes open. The fire door regulations for stadiums guide records the pattern for crowd venues, and the guide on fire doors and Gateway 2 sets out the rules for taller buildings.

Theatres, hotels and City offices need doors that serve daily use and a fire strategy together. An auditorium door in the West End is opened many times a night and must still shut firm on its closer, a hotel kitchen door holds heat and smoke behind a rated leaf, and a City office stair door is opened through the day. The fire door regulations for theatres guide records the pattern for theatre buildings, the hotel fire doors guide covers hotel doors, and the fire door regulations for offices guide sets out the pattern for office buildings.

Fire classes and the furnace test

Each class letter says what the leaf resists. E says the leaf keeps flame and hot gas on the fire side for the stated minutes. EW says the heat passing through the leaf stays under a set limit, and EI says the face away from the fire stays under a set temperature. A 30 minute class fits a low risk opening. A 120 minute class fits a stair core or a plant room, since people take longer to leave from those rooms. The building fire strategy fixes the class for each opening. The specification lists it door by door.

Papers prove the class. The whole doorset goes through the furnace test with every part in place, and the test method, run according BS EN 1634-1:2014+A1:2018, defines E, EW and EI by what the leaf holds back and for how long. The papers name leaf, frame, seals and hardware that were tested as one set, so any change to a part calls for fresh papers or a written assessment. The certification guide notes which papers are worth asking for, and the fire ratings page gives the classes and the test behind them.

Where a door must also stand up to forced entry, a second rating is set beside the fire class. The grade set out upon LPS 1175 Issue 8.2 (September 2024) fixes the forced entry class by tool set and attack time, and the LPS 1175 standard page names them. The dual certification guide covers doors that hold both ratings, and the guide on keeping dual certified doors valid sets out how to keep both ratings in place.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

What each London building usually needs

Each row gives a first figure for one kind of London building. The survey fixes the class for each opening, door by door.

Building in London Door position Class to set Other items specified
Guy’s, St Mary’s, St Thomas’ Wards, corridors and plant rooms EI 60 or EI 120, as the strategy sets Seals and closer
Universities Teaching blocks, labs and student rooms EI 30 or EI 60, as the strategy sets Vision panel, closer and lock
West End theatres and hotels Auditoria, kitchens and service routes EI 60, as the strategy sets Hold open set, seals and closer
Stadiums and Heathrow Concourses, terminals and service routes EI 60, as the strategy sets Hold open set, seals and access control
City offices Stair cores, lift lobbies and stores EI 30 or EI 60, as the strategy sets Closer, seals and reader point

Setting out fire rated steel doors for a London site

Begin with the door list for the building. Each entry carries the opening size, the wall make up, the class and the ironmongery, with the test papers for that class filed beside it. Papers are read before the order goes in, because a doorset with no papers for its class is a risk at handover. The certification guide names the papers worth asking for, and the inspection checklist gives the checks that follow at handover.

Start the specification with the seals. A strip that swells in heat shuts the gap where leaf meets frame, so the strip, its seat and its size are listed door by door, and a smoke seal joins the list where the strategy calls for one. Set the closer so the leaf shuts firm without slamming, list the hinges and the lock as tested, and pick a finish that suits the room. The intumescent seals guide covers the seals, and the fire door gaps guide lists the gap at each edge of the leaf.

From specification to fitting in London

The workshop builds from the signed specification. Sizes from the survey go into the build, so a ward door leaves the workshop at the size the survey measured, and a theatre door leaves it with its vision panel. On site, each frame is set square and level, each leaf is hung, and each seal is checked against its specification.

Next, the maintenance guide sets out the care each door needs once it is in use, so the tested class stays in place year after year.

Put the door list and the building on the quote form, or email the same list to [email protected]. An answer in writing reaches you inside one working day, with the class and a price figure for each door.

Fire door notes for London buyers

Keep the papers with the specification, not with the invoice. The class, the seals and the hardware of each opening are proved by the test papers, and a handover with no papers leaves the class unproved.

Frequently asked questions

What fire class fits a London hospital corridor door?

The fire strategy for the building settles it. Corridor and ward doors in a London hospital often sit at EI 60 or above, while a quiet office door may sit at EI 30. The survey and the strategy fix the class opening by opening.

Do steel fire doors need intumescent seals?

Yes, where the class asks for them. Heat makes the strip swell and shut the gap at the edge of the leaf, so a steel door with no seals in place cannot hold its class. Seals are listed for each door, and a damaged one is replaced at the next inspection.

Can a fire rated steel door take a security rating too?

Yes, where one doorset holds test evidence for each rating. The furnace test sets the fire class, and the SR1 to SR4 scale sets the forced entry grade. Both ratings are written into the specification, with the papers for each beside them.

How are fire doors in a London theatre checked after fitting?

Each opening is measured against its own specification after fitting. The frame is checked for square and level, the closer is tested for a firm shut, and the seals are looked at for gaps. The handover record lists every opening, with the inspection checklist setting out the checks that follow.

Planning fire rated steel doors for a London building?

Send the door schedule and the fire class for each opening, and a specification for every doorset follows in writing. Start a fire door quote to open the survey.

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.