Fire Rated Steel Doors in Manchester
Fire rated steel doors in Manchester, classes E, EW and EI from 30 to 120 minutes. Tested in a furnace, with intumescent seals and evidence for each door.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Manchester
Get a free quote in Manchester
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Manchester
What we supply in Manchester
A fire in a Manchester building turns on minutes. A steel door in a corridor wall is what holds those minutes: flame on one side, people moving to safety on the other, and fire crews with a protected way in. Fire rated steel doors are made for that job, a steel leaf in a steel frame, with seals and hardware that were proved together in one test.
Three letters and a number carry the whole story. E says the leaf stops flame and hot gas. EW says it also caps the heat coming through the leaf. EI says it also caps the temperature on the face away from the fire. The number runs from 30 to 120 minutes, and the furnace method laid down by BS EN 1634-1:2014+A1:2018 sets the heat curve and the timing used to prove each figure.
Those doors work across Manchester in hospitals, universities, offices, shops and airport terminals. Manchester Royal Infirmary fits them at wards and plant rooms, the city’s two universities fit them at lecture halls and student flats, Deansgate towers and Spinningfields offices fit them at stair cores, the Arndale Centre fits them at stock rooms, and Manchester Airport fits them at terminals. ArxBridge supplies the doorset for each opening, with class, seals and hardware written down before anything is ordered. Our Manchester city page covers the wider picture: physical security in Manchester.
Fire doors across Manchester hospitals, campuses and terminals
In a hospital the door has to work while patients are moving. At Manchester Royal Infirmary, wards, corridors and plant rooms each need a leaf that keeps its class as beds and trolleys pass through, with closers and seals that still do their job after years of daily use. Hospital use follows the fire door regulations for hospitals. The day to day checks are listed in the inspection checklist.
At the two universities the driver is numbers of people. Between them they fill lecture halls, laboratories and student flats, and the doors at stair cores and service routes keep the way out clear. Teaching buildings are covered by the fire door regulations for colleges guide, and taller buildings by the fire doors and Gateway 2 guide.
Offices, shops and the airport use the same doors at a faster pace. A stair door in a Deansgate tower opens hundreds of times daily, yet it must still close on its closer, a stock room door in the Arndale Centre guards goods behind a rated leaf, and a terminal door at Manchester Airport keeps smoke out of a staff route. Classes and the test behind them are set out on the fire ratings page, and terminal buildings in the fire door regulations for airports guide.
What E, EW and EI mean in practice
Two things sit in every class: letters and minutes. The letters mark the kind of resistance proved, the minutes mark how long it lasted. A store with little in it may take 30 minutes. A stair core may take 60. A plant room, where people need more time to leave, may take 120. The fire plan for the building fixes the figure opening by opening, and the specification carries it.
Papers are what turn a claimed class into a fact. The test puts leaf, frame, seals and hardware into the furnace as one doorset, and the papers name every part that was in there. Swap one part and the papers no longer match, so a fresh test or a written assessment is needed. The rating table beside LPS 1175 Issue 8.2 (September 2024) covers SR1, SR2, SR3 and SR4 for a door that must also resist forced entry, and those grades appear on the LPS 1175 standard page. Which papers to ask for is set out in the certification guide.
Starting classes for Manchester buildings
Treat the table as a starting point. The fire plan settles the final figure, and the survey fixes the class opening by opening.
| Manchester building | Door position | Starting class | Also named |
|---|---|---|---|
| Manchester Royal Infirmary | Wards, corridors, plant rooms | EI 60 through EI 120 | Seals, closer, smoke seals |
| Universities | Lecture halls, labs, student flats | EI 30 to EI 60 | Closer, vision panel, ironmongery |
| Deansgate towers, Spinningfields | Stair cores, lift lobbies | EI 30 to EI 60 | Closer, seals, access control |
| Arndale Centre | Service corridors, stock rooms | EI 60 | Seals, lock, hold open device |
| Manchester Airport | Terminals, back of house routes | EI 60 | Hold open device, seals |
Putting the specification together
Begin with every opening. For each door, record its measured size, the make-up of the wall, the class and the hardware, and put the test evidence for the class quoted with the specification. A door ordered before its papers are read is a risk at handover, so read the papers first, not when the door arrives. Which papers to ask for is shown in the certification guide, and the handover checks in the inspection checklist.
Give seals the closest attention in the specification. An intumescent strip swells in heat and shuts the gap between leaf and frame, so name the strip type, its position and its size door by door, and add a smoke seal where the fire plan calls for one. Hinges and locks are named as tested, the closer is adjusted until the leaf closes firmly yet quietly, and the finish follows the room it serves. The parts of a tested doorset are listed in the fire door hardware guide, and the fire door gaps guide covers the checks at each edge of the leaf.
From survey to handover in Manchester
Building starts once the specification is signed. The workshop makes each doorset from the signed figures, so a ward door at the Infirmary matches the size taken on site. Frames are fitted square and level, leaves are hung, closers are adjusted, and every seal is matched to the specification for its opening.
The care each door needs after handover is set out in the maintenance guide, so the class proved in the furnace is the class the door keeps.
Use the quote form to send the door schedule, with the class marked for each opening, or write to us at [email protected]. Replies arrive in writing within one working day, giving a price figure and a specification for each doorset.
One check before you order
Check the papers before you place the order. A door whose class has no papers behind it can fail at handover, and papers on a desk are far easier to check than a leaf already hung in a frame.
Frequently asked questions
How long does a fire rated steel door hold in Manchester?
Between 30 and 120 minutes, in E, EW or EI form. A low risk store often takes 30 minutes, while a stair core or plant room takes 60 to 120. The fire plan for the building fixes the figure for each opening.
What wall types can a Manchester steel fire door fit?
The survey records the wall make-up for each opening, and the specification names the frame fixing for that wall. A door ordered without the wall make-up on the schedule is a door that may not fit its opening.
Does a Manchester fire door need a hold open device?
Only where the fire plan asks for one, for example on a terminal or retail service door that is held open in daily use. Where one is fitted, it must release on the fire alarm so the leaf shuts on its closer.
What happens if a Manchester fire door fails its handover check?
The door is put right before the handover record is signed off. A closer that does not shut the leaf, a seal that has pulled away, or a frame out of square is fixed and tested again against the specification for that opening.
Planning fire rated steel doors for your Manchester building?
Send in the door schedule, with the class marked for each opening, and a specification comes back for each doorset on the list. Ask for a free quote and we will set up the survey.