Fire · EI 30 to EI 120

Fire Rated Steel Doors in Wolverhampton

Fire rated steel doors in Wolverhampton, E, EW and EI classes from 30 to 120 minutes, surveyed, specified and fitted with a written record for each leaf.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Wolverhampton
Prefer to talk?+44 7352 267239

Get a free quote in Wolverhampton

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Wolverhampton

What we supply in Wolverhampton

More on this

RatingE, EW and EI classes, 30 to 120 minutes each
BuildSteel leaf and frame, tested as a doorset
EntryForced entry grade where the same leaf needs it
ReplyAnswer inside one working day

A fire rated steel door holds back flame and smoke long enough for people to leave and for the fire service to work. In Wolverhampton that need sits in wards at New Cross Hospital, in lecture rooms at the University of Wolverhampton, in the stands at Molineux Stadium, in the Grand Theatre, and in factory units on the industrial estates around the ring road. Fire rated steel doors give each opening a tested minute figure, with the leaf, frame and hardware tested together as one doorset.

The sections below name what the fire classes mean, where the rating changes across a building, how fire and forced entry ratings sit on one leaf, and the steps from survey to handover. Each opening carries its own class and minute figure, so two doors in one building can hold different ratings.

What the fire rating means on a steel leaf

Each opening takes one class and one minute figure, with the figure sitting between 30 and 120 minutes. E covers integrity, EW adds a limit on radiated heat, and EI adds insulation, so the class names what the leaf holds back and how long the hold lasts. BS EN 1634-1:2014+A1:2018 labels each leaf with its E, EW or EI class and the minutes it held.

The leaf, frame and hardware go through the fire test as one doorset, and the record covers the door as built.

Fire and forced entry on one doorset

This page renders LPS 1175 Issue 8.2 (September 2024) rendering the grades from A1 to H20. A1 takes one minute, B3 takes three, C5 takes five and D10 takes ten. The names for those pairings are SR1, SR2, SR3 and SR4. Each grade in that set measures forced entry, and a fire rated steel doorset can carry one where the same leaf must resist both fire and attack. The guide on dual certification runs through doors that carry a fire class and a forced entry grade on the same leaf.

PAS 24 applies to residential doors only, and a ward leaf or a stadium door takes no rating from it. The LPS 1175 page in the standards section lists each grade with its attack time.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Steel leaf, frame and hardware

A steel leaf takes its strength from the sheet and the core inside it, and the frame holds the leaf square while the fire test runs. Hinges, locks and closers are part of the tested doorset, so a change of hardware after the test needs a fresh look at the record.

Intumescent strips are set into the leaf edge or the frame, and they swell in heat to close the gap round the leaf.

Where the rating changes across a building

The table below pairs each part of a Wolverhampton building with the class it usually takes and the reason for it.

Place Class named in the schedule Why it matters
Hospital wards EI People who cannot move fast need the longest hold
Stair cores EI The escape route must stay clear of smoke and heat
Plant rooms E or EW Fire must stay in the room with less need for insulation
Service corridors EI Corridors carry people and cables between fire zones
Storage rooms E Stock is replaceable but the fire must not spread

Access and opening force

The table below sets the access figures for a leaf under BS 8300 and Approved Document M.

Measure Limit
Opening force, first 30 degrees Below 30 N
Opening force, beyond 30 degrees Below 22.5 N

Even a heavy steel leaf must open with a light push, so closers and hardware are set to the access figure as well as the fire figure. The closers guide for fire doors names the hardware that shuts the leaf and holds it shut.

Seals, gaps and smoke

Smoke moves faster than flame, so the seals round a fire leaf count as much as the leaf. A smoke seal closes the gap when the leaf shuts, and a worn seal lets smoke through long before the fire reaches the door.

The gap round the leaf is checked with the leaf shut, and the record notes the gap at the top, the sides and the threshold. A leaf that has swollen or dropped on its hinges will not shut tight, and the handover check picks that up.

Walk the gaps before the handover is signed. A leaf with the right class and the wrong gap still lets smoke through, and the gap is the part most often missed on a first walk round.

How a Wolverhampton fire door project runs

Survey comes first, and the surveyor records every opening, its size and the class the schedule names for it. The rating and the written specification follow the survey, then supply and fitting follow the specification, with the doorset tested as built. Fitting follows the specification, and the record names the fitter for each leaf.

Send the schedule by post and enter Saffron Road, Romford, Essex RM5 3ES email tomorrow if the delivery date needs to move. A first answer comes back inside one working day. It names the rating check with the budget range for the doors, with the written specification beside them.

Fire rated steel doors around Wolverhampton

Match days at Molineux Stadium and evening shows at the Grand Theatre fill the city centre, and the doors on concourses, back of house areas and escape routes carry the ratings for those crowds. New Cross Hospital adds wards and treatment rooms, and the University of Wolverhampton adds lecture rooms, laboratories and student housing, so one city schedule can cover a ward leaf, a laboratory leaf and a stadium leaf in the same week. The Wolverhampton area page covers the stadium, the university, the hospital, the station and the factories in one place. The security doors range in Wolverhampton covers the leaves beside the fire doors on the same schedule.

The stadiums guide on fire door regulations runs through the ratings for concourses and stands. The theatres regulations guide for fire doors looks at auditoriums and back of house areas. The hospitals regulations guide for fire doors looks at wards, corridors and treatment rooms. SR2 fire doors in Wolverhampton cover leaves that need a forced entry grade on top of a fire class.

Crowded places in the city bring Martyn’s Law duties. The Act has spring 2027 as its planned start, and the SIA will act as regulator. The lower tier covers 200 to 799 people, and the upper tier covers 800 people and above. The Martyn’s Law premises guide lists each tier with the measures it asks for. Email [email protected] for wards and floors in the message so the team can price each opening in turn.

Fitting doors in a live building

Most Wolverhampton doors are fitted while the building stays in use, so the work is planned round ward rounds, lessons and match days. One floor or one wing is done at a time, and the fire route for that area stays open while the leaf is off its hinges.

Keeping the rating valid after handover

A fire door holds its rating only while it is checked, so the record sets the date for the first inspection. Each inspection notes the gaps, the seals, the closers and the latches, and the results go on the same file. The maintenance guide for fire doors sets the checks for each visit, and the record for each leaf holds the date and the result.

A damaged seal or a missing closer must be fixed before the next inspection, and the repair is noted on the same file as the test. Clearances that keep smoke out are named in the gaps guide for fire doors.

Wolverhampton fire door questions

What do E, EW and EI mean on a fire door?

E means the leaf holds back flame and smoke, EW adds a limit on radiated heat, and EI adds insulation so the far side stays cool. The number after the class is the minutes the leaf held in the test, from 30 to 120.

Can a single leaf hold both ratings at once?

Yes, where the same leaf must resist both. Fire testing and forced entry testing run apart, and each rating sits on its own record.

Do fire doors need regular checks?

Yes. Gaps, seals, closers and latches wear with use, and a check finds the wear before the rating is lost in practice. The maintenance guide sets the checks for each visit.

What do you need to quote fire doors in Wolverhampton?

The number of openings, the size of each leaf, the class and minutes the schedule names, and the building type for each door. Add the site address and the floor for each opening.

Ask for a quote for fire rated steel doors in Wolverhampton. Send the number of openings, the size of each leaf and the class the schedule names, then Get a free quote and expect a first answer inside one working day.