Certified physical security

ArxBridge
Installer checking the seal of navy steel fire-rated doors in a UK office corridor

Fire · EI 30 to EI 120

Fire rated steel doors in Solihull

Fire rated steel doors in Solihull for the town centre, the NEC, business parks and hospital wards, with fire class, gaps, closers and fitting on one order.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Solihull
Prefer to talk?+44 7352 267239

Get a free quote in Solihull

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Solihull

What we supply in Solihull

More on this

A steel fire door in Solihull holds a corridor shut against fire and smoke, with leaf, frame, seals and closer fitted to act together from the day the door is hung. A wide gap at the head lets smoke through before the fire reaches the door, and a closer that will not pull the leaf shut leaves the rating as words on paper only. Fire rated steel doors in Solihull cover town centre shops, NEC halls, business park offices and hospital wards, each door cut to its opening and matched against the fire plan of the building.

Touchwood and Mell Square run shopfronts and service doors that take hard daily use, and a fire door on a service corridor must latch first time after a trolley has passed through it a hundred times. The NEC runs hall doors that face exhibition crowds in waves. The physical security in Solihull listing brings the town doors, gates and shutters together.

A fire door order begins with the opening itself, because a frame that sits out of square throws every gap out before the leaf is hung. The survey reads the opening, the wall and the floor at each door, and the specification then names the fire class for that opening with its leaf, frame and hardware. The fire door certification notes set out what a certificate covers, and the answer is sent back within one working day.

Fire classes E, EW and EI30 min to 2 hrs
Gaps, closers and sealsChecked at handover
Dual certification namedFire and security on one leaf
Specification after the surveySent inside one working day

Steel fire doors for Solihull town centre

Town centre doors in Solihull work long days, from shopfronts at Touchwood to service doors behind Mell Square, and the leaf must shut true after every pass of a trolley or a cage. A steel leaf takes the knocks that a timber leaf shows within a year. The fire door regulations for shopping centres notes set out the duties that sit round those doors.

A shop unit door that opens onto a mall needs a closer that shuts the leaf without a slam, and a door that slams all day wears its hinges out. The specification names the closer, the hinges and the seals for each opening.

Fire doors at the NEC and Solihull business parks

The NEC sits in Solihull borough, and its halls run doors that face crowds which arrive in waves for a show and leave in waves at the end of it. A hall door must latch at the end of a wave. Business parks off the M42 run office doors that face a steadier use.

The rating follows the room use rather than the size of the building. Solihull Hospital runs ward doors that must latch first time while trolleys pass, and the fire door regulations for hospitals notes set out the duties that sit round ward doors. The SR2 fire doors in Solihull listing covers the rated fire doors on the town list.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Fire classes, gaps and closers

E, EW and EI name the three classes, each one timed from 30 minutes to two hours, and each class names what the door holds back and for how long. BS EN 1634-1:2014+A1:2018 underpins the test behind those classes. Each class sits beside its test time on the fire ratings page. A door that is named EI 60 in the specification holds integrity and insulation for an hour in the test, and the order carries the class with the leaf.

Solihull building Door use Fire notes
Town centre shops Service and stockroom doors Latch first time, closer set soft
NEC halls Hall and exit doors Latch after each crowd wave
Business park offices Corridor and stair doors Rating follows room use
Hospital wards Ward and corridor doors Latch while trolleys pass, seals intact

Gaps decide whether a fire door works in a real fire. The fire door gaps notes list the head, the jambs and the threshold as the three places to read. A closer that is set too hard slams the leaf and wears the hinges, while a closer that is set too soft leaves the leaf short of the latch, and the fire door closers notes cover the setting. The fire door hardware notes name the hinges, the locks and the seals that hold the rating.

Ratings and the LPS 1175 scale

A dual-certified leaf cuts LPS 1175 Issue 8.2 (September 2024) cutting across two test regimes, and the specification names the fire class beside the security grade. Grades on the LPS 1175 scale run A1 to H20, and each one ties a tool set to a test time, so the grade on the order tells the buyer what the leaf was tested against.

Test time climbs as the grade climbs: SR1 gives a minute, SR2 three minutes, SR3 five and SR4 ten, and the order names those grades A1, B3, C5 and D10. Forced entry testing and fire testing run apart from each other, and the dual certification notes set out how one leaf carries both. 25 October 2023 was the day PAS 68:2013 left the rating list, and ISO 22343-1:2023 took the rating over from there.

Opening force and access under BS 8300

A fire door must shut on its closer yet still open under a light push, so BS 8300 caps the push at 30 N early in the swing and at 22.5 N once the leaf is moving. A closer that is set too hard fails the push test at the handle.

At the handle the survey reads the opening force with a gauge, and the closer is adjusted to the lightest pull that still shuts the leaf and latches it. A door on an accessible route takes a closer with a longer arm or a lower power size. The fire compartmentation notes show how the door sits in the wall that holds the fire back.

Martyn’s Law and crowded Solihull places

A place moves into the enhanced tier at 800 people, and stays in the standard tier between 200 and 799. The Martyn’s Law page carries the detail for both tiers. Its guide for premises notes spell out what each tier must do. The SIA holds oversight, and the start of the duties falls in spring 2027.

The NEC is the largest crowd in the borough, and its halls move into the enhanced tier on a show day, while a business park atrium or a hospital entrance sits under the standard tier.

Honest limits on a steel fire door order

Leaf, frame, hardware and seals come in one order, and the wall round the opening stays outside it, so a wall that needs a builder is listed as a separate job before the fitting is booked. A leaf that arrives with a mark on it is listed for a swap.

A fire door order leaves paint and powder coat untouched, and refinishing a leaf sits outside the order as a separate job. Where the frame is bent, a steel worker goes in first, and the fitting is held back until that work is done.

How the survey and the specification run

Each opening is read in turn before any fitting date is set, and the written specification gives every opening its fire class, leaf, frame and hardware. The written file ends on the circle Saffron Road, Romford, Essex RM5 3ES. Post straightaway once the Solihull door list is ready, and the town centre doors lead the fitting order.

Email [email protected] with quotation details of each opening, and the answer that comes back sets out the next step for the Solihull order. The fire door inspection checklist notes set out the checks that run after handover.

A fire door that is checked at handover and read again each year holds its rating longer than a door that is never looked at after fitting.

Questions from Solihull buyers about fire rated steel doors

Which fire class does a Solihull shop need?

The class follows the fire plan of the building, not the size of the shop. E, EW and EI are the classes, at 30 minutes to two hours, and the specification names the class beside the leaf, the frame and the hardware.

How wide can the gap be round a fire door?

Whether a fire door works in a real fire turns on its gaps. The handover reads the gap at the head, then the jambs, then the threshold.

What opening force must a Solihull fire door meet?

The push caps under BS 8300 are 30 N early and 22.5 N late in the swing. A gauge at the handle reads the force, and the closer is tuned so the lightest pull still shuts and latches the leaf.

Can one Solihull leaf carry both a fire class and a security grade?

It can, when the leaf holds dual certification. The specification pairs the fire class with the LPS 1175 grade, and the two tests run apart from each other.

Plan the steel fire doors for your Solihull building

Send over the door list with a note on the use of each opening, and survey, supply and fitting come in one quoted order. Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.