Certified physical security

ArxBridge
Quayside offices and navy steel entrance door beside the Tyne in Newcastle upon Tyne

Fire · EI 30 to EI 120

Fire Rated Steel Doors in Newcastle upon Tyne

Fire rated steel doors for Newcastle hospitals, universities, stations and arenas, with E, EW and EI ratings, seals and SR class on one order.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Newcastle upon Tyne
Prefer to talk?+44 7352 267239

Get a free quote in Newcastle upon Tyne

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Newcastle upon Tyne

What we supply in Newcastle upon Tyne

More on this

A fire in a Newcastle hospital corridor spreads through the gaps around a door, which is why a fire rated steel leaf is judged by its frame and its seals as much as by its steel. Ward corridors at the Royal Victoria Infirmary sit behind doors that staff push open all day, while plant rooms and records stores at the Freeman Hospital sit behind doors that stay shut for hours on end. A steel leaf answers that risk with a fire rating, a frame and seals named together, so the doorway holds the fire where it started.

Library corridors, lecture rooms and laboratories at Newcastle University and Northumbria University sit behind doors that students use through term. Concourse doors and ticket offices at Newcastle Central Station sit behind doors that crowds use from the first trains of the morning to the last ones at night. Hospitality corridors and kit stores at St James’ Park sit behind doors that crowds use on match days.

A fire rated steel doorset is worth ordering only when the leaf, seals, frame and closer are rated as one unit, because smoke slips through the gap at the head when the frame cannot match the leaf it holds. The forced entry class, the leaf build and the fire rating sit on one written specification, so each doorway can be checked against the same figures before it is made.

For Newcastle hospitals, universities, stations and arenas, ArxBridge makes fire rated steel doors, naming the fire rating, leaf build and frame on one written specification. The area page titled physical security in Newcastle upon Tyne gathers the other Newcastle services. The dual certification guide explains how fire and security ratings sit together.

Fire ratingE, EW and EI, 30 to 120 min
Leaf buildSteel leaf, seals rated
Frame and sealsRated alongside the leaf
Forced entrySR1 to SR4, one per doorway

Where Newcastle buyers fit fire rated steel doors

Ward corridors at the Royal Victoria Infirmary sit behind doors that shut on their own after every pass, because a leaf left open lets smoke travel the corridor. Plant rooms and records stores at the Freeman Hospital sit behind doors that stay shut for hours, with staff passing through as patients wait nearby. Glazing belongs on a hospital leaf only where staff need to see through it, because every glazed panel changes the pull of the closer on the leaf.

Library corridors and lecture rooms at Newcastle University and Northumbria University sit behind doors that students use through term. A leaf in a teaching block takes knocks from trolleys and cases and stays true. Concourse doors and ticket offices at Newcastle Central Station sit behind doors that crowds use all day, and the leaf there stays true while the station stays open around it.

Restaurant kitchens and office corridors on the Quayside sit behind doors that face the river walk, where cold winds and damp air off the Tyne meet the leaf. Hospitality corridors and kit stores at St James’ Park sit behind doors that crowds use on match days, and terminal corridors and control rooms at Newcastle Airport sit behind doors that travellers use in all weathers. The hospital security doors guide takes ward corridors and plant rooms in hospitals as its subject, and the fire door certification guide shows the evidence behind the rating.

Five Newcastle buildings and the doorset that suits each one

The table below lists the Newcastle building, its doorway, its leaf and the fitting that keeps the leaf true for five openings.

Building Doorway Leaf Fitting
Royal Victoria Infirmary ward corridor Corridor door on the ward Steel leaf, narrow glazed panel Seals at head and jambs
Freeman Hospital plant room Door to the plant room Steel leaf, solid, no glazing Closer sized for the leaf weight
Newcastle University library corridor Corridor door in the library Steel leaf, glazed panel for sightlines Hinges sized for the leaf weight
Newcastle Central Station concourse Door from the concourse Steel leaf, glazed panel for the concourse Frame depth sized for the wall
St James’ Park hospitality corridor Corridor door on match days Steel leaf, glazed panel at eye level Lock and closer sized for the leaf
Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Fire ratings for the leaf, the frame and the seals

The fire rating for the leaf derives BS EN 1634-1:2014+A1:2018 designating E, EW and EI from 30 minutes to two hours. The rating is tested on the leaf, seals and frame as one unit, so a leaf tested alone proves nothing about the doorway it will sit in. The fire ratings page holds the whole scale, and the fire door certification guide holds the evidence behind the rating.

The written specification charts LPS 1175 Issue 8.2 (September 2024) compiling the forced entry class next to the fire rating for each doorway. One minute with an A1 tool set gives SR1, three minutes with B3 gives SR2, five minutes with C5 gives SR3, and ten minutes with D10 gives SR4. The whole scale is listed on the forced entry standard page, and the ratings compared guide lays out where the three ratings part company.

Fire rating and forced entry class answer different questions, so proof of one is never proof of the other. A leaf that holds back fire for an hour may still fail a lever test, and a leaf that holds against a lever may still fail a fire test, which is why both classes sit on the same written specification. The dual certification guide covers a leaf that must hold both, and the keeping both ratings true guide covers what keeps them true.

Access, closers and the Tyne weather

A fire rated leaf on a ward corridor opens with a push that staff and patients can manage, and its handle sits where a hand finds it without a stretch. The security doors access Approved Document M guide names the thresholds, opening force and handles for doorways that the public use.

A closer sized for a light leaf lets a heavy steel leaf stand open, and a leaf that stands open lets smoke travel the corridor. The closer strength is written beside the leaf weight, and the seals are checked at the head and the jambs after the wet months, because a seal that has lost its give no longer closes the gap it was made to close. The hinges carry the same weight, and a hinge that lets the leaf drop puts the seals out of line.

Cold river air off the Tyne works on Quayside frames through the winter, so a doorway there needs seals that keep their flex when the temperature drops and a frame that lets rain run off instead of sitting in the channel. The transport hub security requirements guide handles station doorways the same way, and the fire door maintenance guide names the checks that keep the seals and the closer true.

What a Newcastle doorway needs before a price is set

The surveyor takes the wall build, the traffic, the leaf height and the leaf width for every doorway, and writes the fire rating beside those figures. From those figures the specification sets out the leaf build, the seals and the fire rating, with the SR class and the price following from the same figures. The drawings are checked against those figures before the leaf is made, because a second visit to measure again wastes a day.

Send the fire rating, the leaf height and the leaf width each doorway must hold to the Newcastle bathhouse Saffron Road, Romford, Essex RM5 3ES. Call now through the contact page for the written specification and the price. Email [email protected] and begin with the frame depth and the drawings for each doorway. A written note then reaches the buyer naming the leaf build, the specification and the price for each doorway, for the buyer to check every figure first.

What Newcastle buyers should note

Put the fire rating, the seal type and the forced entry class in one written specification, with the frame depth, the leaf height and the leaf width beside them. A leaf ordered without its seals leaves a gap that only the doorway measure will show.

Questions about fire rated steel doors in Newcastle upon Tyne

Can a fire rated steel leaf hold against forced entry too?

It can, when a forced entry class sits alongside the fire rating on the leaf. The specification writes SR1, SR2, SR3 and SR4 against each doorway in turn.

Can a fire rated leaf carry glazing?

Yes, rated glazing is tested alongside the leaf, so the glass rating stands beside the fire rating on the same specification.

What happens when the seals wear?

A worn seal no longer closes the gap at the head and the jambs, so smoke can travel the corridor past a shut leaf. The seals are checked after the wet months, and a seal that has lost its give is changed before the next check.

Can the leaf be used on an escape route?

Yes, when the leaf opens in the direction of escape and the handle sits where a hand finds it without a stretch.

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.