Fire Rated Steel Doors in Liverpool
Fire rated steel doors in Liverpool, classes E, EW and EI from 30 to 120 minutes. Tested as a full doorset, with intumescent seals and evidence for each door.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Liverpool
Get a free quote in Liverpool
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Liverpool
What we supply in Liverpool
A Liverpool buyer with a schedule of openings across a hospital, a campus and a dockside shed faces one question at each door: how long must it hold? A corridor door of steel is tested as a whole, not as parts. Leaf, frame, seals and hardware go into the furnace together, and the class the doorset earns says how long it keeps flame, heat and smoke on the far side. Fire rated steel doors are the doors a buyer picks when an opening needs a proved time, not a guess, and the time runs from 30 minutes to 120 minutes in E, EW and EI forms.
EI is the fullest form. It holds down the temperature on the far face as well as stopping flame and hot gas, so a door that must protect a stair core or a plant room often takes EI. E stops flame and hot gas alone. EW sits between the two, capping the heat radiated through the leaf. The test route following BS EN 1634-1:2014+A1:2018 demands a full doorset in the furnace, with the temperature curve and the timing set by that standard.
The Royal Liverpool Hospital uses them in wards and plant rooms, Liverpool’s two universities use them in lecture blocks and student rooms, Liverpool ONE and the Albert Dock use them in service corridors and stock rooms, the Port of Liverpool uses them in sheds and offices, and Liverpool John Lennon Airport uses them at terminals. ArxBridge supplies each doorset with its class, seals and hardware set out in writing before anything is ordered. Rated work across the city is covered in physical security in Liverpool.
Doors for Liverpool hospitals, campuses, shops and docks
The Royal Liverpool Hospital needs doors that keep working while patients move. Beds and trolleys pass through ward and corridor doors all day, plant room doors guard the services behind them, and closers and seals have to hold up after years of that use. For hospital buildings, the fire door regulations for hospitals guide is the reference, and the inspection checklist holds the day to day checks.
Student numbers drive the pattern at the two universities. Between them they fill lecture blocks, laboratories and student rooms, so stair cores and service routes stay clear for escape. The Knowledge Quarter and the Baltic Triangle add studios and workspaces with the same need, and the grounds at Anfield and Goodison Park add stands and concourses where large crowds need clear routes out. Teaching buildings are covered by the guide on fire door regulations for colleges, and office and public buildings by the guide on fire door regulations for offices.
Retail, docks and the airport work the same doors harder. A stock room door in Liverpool ONE guards goods behind a rated leaf, a dockside shed door at the Port of Liverpool faces damp and heavy use, a stair door in a port office opens many times a day, and a terminal door at Liverpool John Lennon Airport holds smoke back from a staff route. The fire ratings page lists the classes and the test behind them, and the airports guide on fire door regulations for airports covers terminal buildings.
How the class is read
The number is the time the doorset held in the furnace. Thirty minutes fits a low risk store. Sixty fits a stair core. One hundred and twenty fits a plant room where escape is slow. The fire plan for the building sets the number for each opening, and the specification records it. The letters say what was proved: E for flame and hot gas, EW for radiated heat as well, EI for the temperature on the far face as well.
The papers are the proof. Leaf, frame, seals and hardware went into the furnace together as one doorset, and the papers name each part that was there. Change one part and the papers no longer cover the door, so a new test or a written assessment follows. The grade list using LPS 1175 Issue 8.2 (September 2024) says SR1, SR2, SR3 and SR4 are the grades where a door must also hold back a forced entry attempt, and the LPS 1175 standard page lists those grades. The certification guide lists the papers worth asking for before an order is placed.
A starting class for each Liverpool building
Start from the table, not from a guess. The fire plan has the last word, and each opening is surveyed before its class is fixed.
| Liverpool building | Door position | Class to start from | Extra items |
|---|---|---|---|
| Royal Liverpool Hospital | Wards, corridors, plant rooms | EI 60-120 | Smoke seals, closer, intumescent strips |
| Universities | Lecture theatres, laboratories, student rooms | EI 30 up to EI 60 | Vision panel, closer, ironmongery |
| Liverpool ONE, Albert Dock | Service corridors, stock rooms | EI 60 | Lock, seals, hold open device |
| Port of Liverpool | Sheds, stores, port offices | E 30 up to EI 60 | Threshold, lock, seals |
| Liverpool John Lennon Airport | Terminals, staff routes | EI 60 | Hold open device, seals |
What goes into the specification
Begin by listing every opening. For each door, write down the measured size, the build of the wall, the hardware and the class, and keep the papers for the class quoted with the specification. Papers are read before the door is ordered, not when it arrives, since a door without matching evidence can fail the handover checks. The certification guide lists the papers worth asking for, and the fire door closers guide shows the closer setting for each leaf.
Seals get the closest attention. Heat makes an intumescent strip swell until the gap between leaf and frame is shut, so the strip is named by type, position and size for each door, and a smoke seal is added where the fire plan calls for one. The hinges and lock are the tested set, the closer is tuned until the leaf shuts firmly without slamming, and the finish follows the room. The escape route pattern is set out in the emergency exit doors guide, and the price drivers for a doorset in the fire door cost factors guide.
The job, in order
The workshop builds once the specification is signed. It works to the signed figures, so a ward door for the Royal Liverpool is built to the size taken on site. On site, the frames are fitted square and level, the leaves are hung, the closers are set, and the seals are checked door by door against the specification.
The maintenance guide explains the care each door needs once fitted, so the door keeps the class its papers claim.
Send the door list in through the quote form, with the class marked for each opening. The team can be reached at [email protected], and a reply in writing should reach you inside one working day, with a price figure and a written specification for each opening.
Before the order goes in
Check leaf, frame and seals as one unit at handover. A tested class belongs to the whole doorset, so a changed hinge or a missing seal can leave a fitted door short of the class on its papers.
Frequently asked questions
How is the class for a Liverpool opening chosen?
The fire plan for the building fixes it, opening by opening. Thirty minutes often fits a low risk store, sixty fits a stair core, and a plant room takes 60 to 120. The survey confirms the figure for each door.
Can a Liverpool fire door carry a vision panel?
It can, provided the panel formed part of the tested doorset. Its size and glazing are named in the specification, and the papers for the class quoted must cover the panel as fitted.
Does a dockside door at the Port of Liverpool need a different finish?
The finish follows the room and the conditions the door faces, and it is named in the specification with the class and the hardware. A shed door facing damp and heavy use takes a finish suited to that setting.
What is checked on a Liverpool fire door at handover?
Handover checks the frame for square and level, tests each closer and seal against the specification for its opening, and records every opening with its class, seals and hardware in the handover record.
Planning fire rated steel doors for a Liverpool building?
Send the door list in, with the class marked for each opening. A specification will come back for each doorset. Ask for a free quote to arrange the survey.