Fire · EI 30 to EI 120
Fire rated steel doors in Edinburgh
Fire rated steel doors in Edinburgh for hospitals, hotels, schools and offices, tested to BS EN 1634-1 with E, EW and EI classes from 30 to 120 minutes.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Edinburgh
Get a free quote in Edinburgh
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Edinburgh
What we supply in Edinburgh
A steel door on a stair core in Edinburgh has to hold fire back and still open with a light push, and leaf, frame and seals have to work as one doorset when the alarm sounds. Our fire rated steel doors for Edinburgh are built as a tested doorset, so one test record covers leaf, frame, seals and ironmongery together. Each doorset is made to the measurements of its own opening, and its fire class is put in writing before any door is ordered.
Edinburgh Airport runs terminal doors where staff and passengers pass all day, Murrayfield Stadium fills its concourse doors with crowds on match days, and hotels along Princes Street and the Royal Mile run bedroom corridor doors. The Royal Infirmary of Edinburgh runs ward doors, stair doors and plant room doors where a fire door stands between patients and a stair, and the University of Edinburgh runs teaching blocks, libraries and halls where doors open for student groups between sessions. At those places the door has to close firmly on its closer and still open under a light push.
Every doorset is made for the one opening it fills, with fire class, security class and finish written in a single specification. Our Edinburgh page gives the wider city picture. The doors here sit on stair cores, corridors and plant rooms, where a door has to hold fire back and let people through at once.
Steel doors that hold fire and forced entry in Edinburgh
At the Royal Infirmary, ward doors and stair doors swing all day, and a door there has to close on its closer after every pass without slamming on a patient or a trolley. The seals close the gap around the frame, the closer is matched to the leaf weight, and the rating holds because the seals and the closer were tested with the leaf. Survey visits are timed round ward routines, with the visit planned so no ward closes for the survey.
Hotels on Princes Street and the Royal Mile run corridor doors that guests pass through late at night, and the University of Edinburgh runs halls where doors open for groups between sessions. Both need a leaf that closes firmly yet quietly, with hinges and closers matched to the load, and a threshold cut to suit the internal floor. Murrayfield Stadium fills its doors with crowds on match days, and Edinburgh Airport runs terminal doors in all weather, and at those openings the finish is chosen for rain and daily wear.
Fire classes and the steel leaf
The fire class for a steel door comes from the furnace test it passed. The leaf, frame and seals are tested together as one doorset, as BS EN 1634-1:2014+A1:2018 requires, and the test gives E, EW and EI ratings of 30, 60, 90 and 120 minutes, with the rating for each doorset taken from its own test record alone. A steel door that satisfies LPS 1175 Issue 8.2 (September 2024) retains both its fire class and its forced entry class, and the test papers are checked again before handover. SR1 goes with tool set A1. SR2 goes with B3. SR3 goes with C5. SR4 goes with D10. Our fire ratings page explains the classes, and the SR classes appear on our LPS 1175 standard page.
Access rules set how hard a door may push back. The push must stay under 30 N while the leaf is in its first 30 degrees. After that point the limit is 22.5 N, so a door that holds fire still opens for a person with limited strength. The closer is picked for the leaf weight and the opening figure together, and the hinges are named as tested. How a fire door and a security rating sit in one doorset is explained in our dual certification guide, and the keeping a dual certified door valid guide explains the care each door needs after fitting.
Price follows size, class and ironmongery, and the fire door cost factors guide lists the items that decide the price. The certification guide lists the papers to ask for, and a steel leaf beside a timber leaf is compared in our steel and timber fire doors guide.
Which doorset suits each Edinburgh building
Use the table to match a building type with a common doorset choice. Before the workshop starts, the survey pins down class, leaf and ironmongery door by door, and the written specification is agreed at that point.
| Building | Where the door sits | Fire class | Fittings named |
|---|---|---|---|
| Royal Infirmary of Edinburgh | Ward exits and stair cores | EI 60, as the fire plan states | Intumescent seals, closer, threshold |
| University of Edinburgh | Teaching blocks and hall entrances | EI 30 or EI 60 | Vision panel, lock set, closer |
| Murrayfield Stadium | Concourse and service entrances | EI 60, as the fire plan states | Closer, seals, reader |
| Princes Street and Royal Mile hotels | Bedroom corridors and stair doors | EI 30, as the fire plan states | Closer, seals, lock |
| Edinburgh Airport | Terminal doors and service corridors | EI 60, as the fire plan states | Intumescent seals, closer, threshold |
| Holyrood and Leith offices | Office entrances and stair cores | EI 30 or EI 60 | Vision panel, lock set, closer |
How the specification for an Edinburgh steel door is set
Begin with a full list of openings. Record the size, wall type, class and ironmongery for every door, and file the test documents that prove the class quoted beside each entry. Do not order until those documents have been seen. Ordering without them risks a hold-up at handover, so checking comes first and ordering comes second. The SR2 fire doors in Edinburgh page covers the forced entry side of the same openings, and the fire door rules for stadiums guide covers the Murrayfield side of the work.
Leaf, seals and threshold are settled as one set. The leaf carries the fire class, the seals close the gap around the frame, and the threshold is set to the internal floor and to the weather outside. Set the closer so the leaf closes firmly yet quietly, and name the hinges and the lock exactly as they were tested. Pick a finish that suits the frontage. If access control needs a reader, mark where it goes and where its power comes from on the drawing as well.
Ordering and fitting in Edinburgh
With the specification agreed, the workshop builds each doorset to it, using the survey figures, so a hospital stair door is built to the surveyed size. Fitters level and plumb each frame on site, hang each leaf on its hinges, then set each closer so the leaf shuts firmly.
Find Arxbridge on Saffron Road, Romford, Essex RM5 3ES, open through the working week.
Use the quote form for the opening list, with the class written against each opening, or email that list to [email protected]. Send the sizes and the fire rating needed, and a written reply reaches you inside one working day, price and specification in the reply.
Steel fire door notes for Edinburgh buyers
Push the leaf open with one hand before handover is signed. A leaf that opens under a light push and still shuts hard on its closer shows the closer is set right, and a leaf that drags on the threshold shows the frame needs work before the fitters leave.
Frequently asked questions
Does a steel fire door in Edinburgh still open easily for a person with limited strength?
Yes, where the closer is set for the leaf weight and the opening figure. The push stays under 30 N at the start of the swing, and under 22.5 N after the leaf passes 30 degrees, so the door opens under a light push and still shuts hard on its closer.
Can a steel fire door also hold a security rating in Edinburgh?
Yes, where one doorset has passed the furnace test and the forced entry test together. The furnace test proves the fire resistance, and the forced entry test proves the SR class. Each rating is written into the specification with the test record that proves it.
What fire class does a hospital or a hotel in Edinburgh need?
The class follows the fire plan for that building, and the survey names it door by door. EI 30 and EI 60 are the classes most often named, and the documents proving the class quoted are filed with the specification.
How are steel fire doors checked after fitting in Edinburgh?
After fitting, the fitters level-check each frame, check each closer and seal for its own opening, and record class, leaf, seals and ironmongery for every opening in the handover record.
Fire rated steel doors for an Edinburgh building?
Tell us the openings and the class for each door, and the reply will hold a specification for every doorset. Get a free quote and we book the survey from there.
Other areas
Fire rated steel doors in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.