Fire · EI 30 to EI 120
Fire rated steel doors in Oxford
Fire rated steel doors in Oxford for colleges, hospitals, shops and offices, tested to BS EN 1634-1 with E, EW and EI classes from 30 to 120 minutes.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Oxford
Get a free quote in Oxford
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Oxford
What we supply in Oxford
Oxford asks a lot of one door. In a college stair core, a hospital corridor or a shop service passage, the leaf has to block fire and still let people pass, and a steel leaf does both jobs only when leaf, frame, seals and ironmongery were tested as one doorset. Our fire rated steel doors for Oxford are made to the measurements of each opening, with the fire class for that opening written down before any door is ordered.
University of Oxford colleges need doors for halls, libraries and stair cores where students and staff pass all day, and the Bodleian Library needs reading room doors where quiet counts as much as fire safety. At the John Radcliffe Hospital, doors on wards, stairs and plant rooms guard the routes patients use to reach a stair, while Westgate Oxford needs corridor and service doors that work through long trading hours, and Oxford station needs ticket hall and staff room doors where crowds move at peak times.
Every opening in Oxford is measured on its own before a door is made for it, and the fire class, the security class and the finish for that opening go into one written specification. Our physical security in Oxford page gives the wider city picture, and the doors on this page guard stair cores, corridors and plant rooms, with each leaf blocking fire while still letting people pass.
Where steel fire doors sit in Oxford
In the colleges, hall doors and stair doors open for groups between lectures, library doors open for readers through the day, and doors on narrow stone stairs need measuring to fit openings that were never built to one size. At the Bodleian Library, reading room doors need a leaf that shuts quietly, so hinges and closer are picked to close the door without a slam.
The John Radcliffe Hospital needs ward doors that swing all day, stair doors that shut after every pass, and plant room doors that guard boilers and electrical rooms. Westgate Oxford needs corridor doors for shops and service doors for stock rooms, Oxford station needs ticket hall doors where crowds move at peak times, and the Cowley plant needs workshop doors where shifts change through the day. Survey visits work round ward routines and teaching times, so no ward and no reading room closes for the survey.
Fire classes and the steel leaf
Each fire class names a different job for the leaf. E keeps flame and hot gas back on the fire side, EW keeps flame and gas back and also limits the heat that radiates through the leaf, and EI keeps flame, gas and heat back and keeps the face away from the fire cool for the rated time. Classes run from 30 minutes to 120 minutes, and the class for each opening follows the fire plan for that building. One line in the test record analyses BS EN 1634-1:2014+A1:2018 boarding, and the buyer should ask which sample covers the leaf on site. The fire ratings page lists every class, and the gap sizes guide shows why the space round the leaf counts as much as the leaf itself.
| Class | What it holds back | Typical Oxford use |
|---|---|---|
| E | Flame and hot gas | College stair cores |
| EW | Flame, gas and radiated heat | Corridors near reading rooms |
| EI | Flame, gas, heat and insulation | Ward doors and plant rooms |
A steel leaf is folded from sheet and filled to suit the class, the frame is fixed square and plumb in the opening, and the seals close the gap round the frame when the leaf shuts. Hinges and closers are named in the test record, the closer is matched to the weight of the leaf, and the threshold is cut to suit the floor inside and the weather outside. Compartmentation decides where each class belongs, and the hardware guide covers hinges, closers and locks in the same doorset.
One doorset for fire and forced entry
A single leaf can take both ratings, fire and security, where the same doorset has been through a furnace test and a forced entry test. When a brief asks LPS 1175 Issue 8.2 (September 2024) bumping the class from SR2 to SR3, the fire rating still has to be named first, because a door that resists attack and fails in fire leaves the building unprotected. SR1 is tested at A1 for 1 minute, SR2 at B3 for 3 minutes, SR3 at C5 for 5 minutes and SR4 at D10 for 10 minutes, and the class goes in the specification beside the test record that backs it. The LPS 1175 page gives the standard in full, and the guide to dual certification shows how the two ratings sit in one doorset. SR2 fire doors suit many colleges and offices where a mid level of resistance is enough.
Under Martyn’s Law, the tier turns on headcount: 800 people or more counts as the top tier, and 200 to 799 people counts as the standard tier, with the law expected to start in spring 2027. College halls and the larger venues in Oxford sit in that picture, and a hall that expects large gatherings should name the tier in its security plan before the doors are specified. The Martyn’s Law page gives the tiers as written, and the college doors guide covers doors for teaching buildings in more detail.
Ordering and fitting in Oxford
A survey of each opening leads the work, and the specification that follows records class, sizes, finish and ironmongery door by door. Manufacture follows those drawings, and proof of the quoted class travels with every doorset. The cost factors guide shows what changes the price of a doorset, and the student rooms guide covers doors for halls of residence.
On site, fitters bring each frame square and true, hang each leaf on its hinges, then tune each closer until the leaf closes with a firm, quiet pull. Each seal is checked against the figure for its own opening, and each leaf is checked against the measurements the survey recorded. Post a brief to the manor Saffron Road, Romford, Essex RM5 3ES phone during office hours, or send the list of openings to [email protected] and list the fire class against each opening.
After handover, each door needs a routine check of closer, seals and hinges, and the maintenance guide gives the checks in order. The inspection guide gives the same checks as a list for the person who walks the building. A door that drags on the threshold or hangs open needs the frame or the closer set again.
Steel fire door notes for Oxford buyers
At handover, close each leaf and listen for the latch. A leaf that latches cleanly and opens again under a gentle push is set right, and a leaf that rattles in the frame or needs a shove to latch wants the hinges or the closer adjusted again before the fitters leave.
Frequently asked questions
Can a steel fire door fit an old college stair in Oxford?
Yes, where the survey measures the stone opening door by door and the frame is made to those figures. The leaf, frame and seals are built as one doorset for that opening, and the closer is adjusted so the leaf shuts firmly yet opens under a gentle push on a narrow stair.
Can a person with limited strength open a steel fire door in Oxford without strain?
Yes, where the closer matches the weight of the leaf. The push at the handle stays under 30 N through the opening arc up to 30 degrees, and under 22.5 N past that point, so the leaf opens under a gentle push and still closes hard on its closer.
What fire class does a hospital ward or a college hall in Oxford need?
The fire plan for that building sets the class, and the survey names it for each door in turn. EI 30 and EI 60 turn up most often for those rooms, and the papers that prove the class quoted travel with the specification.
What checks follow fitting for steel fire doors in Oxford?
After fitting, the fitters check each frame for level, each closer and seal against its own opening, and note the class, leaf, seals and ironmongery of every opening in the handover record.