Fire · EI 30 to EI 120
Fire rated steel doors in Cambridge
Fire rated steel doors in Cambridge: tested doorsets for colleges, hospitals, stations and science parks, with E, EW and EI ratings from 30 to 120 minutes.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Cambridge
Get a free quote in Cambridge
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Cambridge
What we supply in Cambridge
A steel door on a Cambridge stair well is asked to do two things in the same moment: keep flame and smoke on one side, and swing open under a gentle hand when people head for the stair. Our steel doors rated for fire in Cambridge are ordered as a single tested unit, leaf, frame, seals and ironmongery all covered by one test record. Each unit follows the measurements of its own opening, the class put in writing before any order goes in.
Across the colleges of the University of Cambridge, doors guard stair wells, passages and plant rooms. At Addenbrooke’s Hospital, doors stand on ward routes, stair wells and service passages, where a rated leaf sits between patients and the way out. Cambridge station sees crowds pass its entrance doors through the day, the Grand Arcade has shopfront and back of house doors behind its retail units, and the science parks have lab and office doors guarding passages. In each setting the leaf must shut firmly on its closer and still move under a light hand.
For every opening, one written note records the finish beside the fire mark and the security mark. Our physical security in Cambridge page puts these doors in the wider city setting, and the doors described here guard stair wells, passages and plant rooms, where a leaf resists flame while people use it daily.
What a Cambridge steel fire door is asked to do
At Addenbrooke’s, ward and stair doors move through the day, and each one must shut on its closer after every person passes, without banging against a patient or a trolley. Seals fill the edge round the frame, the closer suits the weight of the leaf, and the rating stands because seals and closer went through the test beside the leaf. A visit to measure is planned round ward routines, so no ward is closed off.
College passages see students pass late at night, and science park labs see staff carry kit from room to room. Each setting wants a leaf that shuts firmly and quietly, hinges and closers sized to the load, and a threshold shaped to the floor inside. Cambridge station has entrance doors crowds push through at busy hours, and the Grand Arcade has back of house doors behind its shop units.
How the fire class is fixed for each opening
The class for a steel door follows the furnace test it went through. Leaf, frame and seals go through that test as a single unit, and the marks given are E, EW and EI, at 30, 60, 90 or 120 minutes, with each unit judged on its own test record alone. The furnace test advances BS EN 1634-1:2014+A1:2018 auditing the leaf, the frame and the seals as one doorset, and the written record for each opening states which class was passed.
A steel door that also carries a forced entry class keeps both marks in a single unit. The buyer approves LPS 1175 Issue 8.2 (September 2024) browsing the test evidence before the order is signed, and the class is put beside the fire class in the same written note. SR1 is paired with A1, which allows 1 minute. SR2 is paired with B3, which allows 3 minutes. SR3 is paired with C5, which allows 5 minutes. SR4 is paired with D10, which allows 10 minutes. The classes are laid out on our fire rating classes page, and our LPS 1175 page covers the SR marks.
Push force, closers and everyday use
Rules on access limit how hard a door may resist. Through the first 30 degrees the push stays below 30 N, and past that point below 22.5 N, the limits set in BS 8300 and Approved Document M. A closer is chosen for the weight of the leaf and that push figure together, and the hinges named are the tested ones. Our dual certification guide lays out how a fire mark and a security mark sit in a single unit, and the care for a dual certified door guide covers what each door needs once fitted.
What a door costs turns on size, class and ironmongery. Our fire door cost factors guide runs through the items that fix it. The certification guide runs through the papers worth asking for, and our steel and timber compared guide weighs a steel leaf against a timber one.
Places in Cambridge where rated steel doors belong
A rated steel door belongs wherever a building needs a barrier against flame and smoke that people still pass through day to day. In a lab the leaf may stand between a lab room and a passage, in a college on a stair well or in a hall, and in a hospital on a ward or a service passage. The fire plan picks which openings need a rated leaf and which period each one needs, and the leaf ought to be picked to suit that plan, not the plan to suit the leaf.
Passages and stair wells call for care, since people use them as the way out. A leaf on such a route must shut fully on every use, with a closer sized to the weight of the leaf and a latch that holds without a fight. Busy halls and arcades also fall under the expected Martyn’s Law tiers, which sort premises by people present: 200 to 799 standard tier, 800 or more enhanced tier, commencement expected spring 2027. The college fire doors guide covers stair and passage doors, and the shopping centre fire doors guide covers service and stock room doors.
Settling ratings, seals and ironmongery before ordering
The mark on a fire door is given as a period and a class, best chosen with the fire plan open. E, EW and EI marks cover 30, 60, 90 or 120 minutes. The table below puts the usual periods beside the places where each one is used.
Seals and ironmongery fix whether a rated leaf acts as tested. Intumescent seals swell once the heat reaches around 200 to 250 degrees, sealing the edge where leaf meets frame, while smoke seals slow cold smoke before the heat grows. At handover, a gauge is run round the leaf, the clearance is held at 4 mm, and our guide to fire door gaps shows where to measure. For more, read our certification guide, our intumescent seals guide, plus the fire ratings page.
| Period | Class | Where it is used in Cambridge |
|---|---|---|
| 30 minutes | E, EW or EI | Workrooms, retail units and short passages |
| 60 minutes | E, EW or EI | Stair wells, plant spaces and lab rooms |
| 90 minutes | E, EW or EI | Stores with higher risk and riser shafts |
| 120 minutes | E, EW or EI | Walls between compartments and plant with higher risk |
A fire door is a tested unit, not a leaf on its own. Fix the class, the seals and the ironmongery in a single written note.
Putting a Cambridge fire door brief together
A sound brief opens with the building, the fire plan and the openings. Send the address, the count of doors, the mark for each opening and any drawings or photos you have ready. Note the rooms behind each leaf and the traffic each one carries, because a leaf that suits its traffic holds up longer than one picked on size alone.
The fire door maintenance guide covers the checks that keep a unit working once handed over, and the how to specify guide lists the steps from survey to handover.
Write to [email protected] with your address, the count of doors and the mark for each opening, and the reply will hold a budget range and a written note for each unit. You can also post a brief to our loft Saffron Road, Romford, Essex RM5 3ES send us a note with the drawings, and we will confirm receipt and the next step.
Which fire rating fits a steel door in a Cambridge laboratory?
The fire plan fixes the mark. Most lab rooms are given 60 minutes or more, a passage leaf often 30 minutes, and the survey names the period leaf by leaf.
Can one steel doorset hold fire and forced entry ratings together?
Yes, one unit can carry both marks, with leaf, frame and ironmongery proved in the furnace trial and then in the forced entry trial. Both marks go into the same written note, so the maker builds to each one.
How is the gap round a fitted fire door checked in Cambridge?
A gauge goes round the leaf at handover, and the clearance is kept to 4 mm. The readings go into the handover file, where the next inspection can find them.
Does a college stair door in Cambridge need a smoke seal as well?
A leaf on an escape route often needs both seals, because the smoke seal slows cold smoke before the heat grows enough for the intumescent seal to swell. The fire plan names the leaves that need both.