Certified physical security

ArxBridge
Harbourside converted buildings with steel entrance doors in Bristol

Fire · EI 30 to EI 120

Fire Rated Steel Doors in Bristol

Fire rated steel doors for Bristol hospitals, offices, schools and stadiums, built to the fire test standard with evidence and a reply in one working day.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Bristol
Prefer to talk?+44 7352 267239

Get a free quote in Bristol

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Bristol

What we supply in Bristol

More on this

Bristol calls for fire rated steel doors where a corridor, a service riser, a stair core or a plant room must keep fire and smoke on one side for a stated time. The harbourside, the shops of Cabot Circus and The Mall at Cribbs Causeway, offices by Temple Meads and wards at Southmead Hospital and Bristol Royal Infirmary all rely on doors along escape routes and compartment lines, with fire rated steel doors standing guard on those lines right across the city.

The use of each building sets where the doors belong. Wards, operating theatres and pharmacy stores in the two main hospitals need doors that close, latch and seal when the alarm sounds. Lecture halls and laboratories at UWE Bristol and the University of Bristol need the same, as do classrooms and halls in suburban schools and the concourses of Bristol Temple Meads station. That building’s fire strategy sets the rating at every opening, and leaf, frame, seals and hardware then count as a single tested unit built to that rating, and for rated work in the rest of the city, see physical security in Bristol.

Harbourside and Temple MeadsStation buildings, offices and venues by the water
HospitalsSouthmead Hospital, Bristol Royal Infirmary
UniversitiesUniversity of Bristol, UWE Bristol
Shops and stadiumsCabot Circus, Cribbs Causeway, Ashton Gate

Which Bristol buildings ask for these doors first

Civic and office stair cores and risers generally carry the longest ratings in the city. Doors in the offices by Temple Meads and the harbourside, in council buildings and in hotels by the station sit on escape routes used by staff and visitors, so every opening needs a fire rating equal to the compartment wall beside the opening. The fire door regulations for offices guide walks through how an office schedule handles escape doors, risers and service rooms.

Hospital and university estates mix the work differently. Operating theatres, pharmacies, plant rooms and wards at Southmead Hospital and Bristol Royal Infirmary follow a single estate plan. Student blocks, teaching halls and laboratories at UWE Bristol and the University of Bristol spread over campuses in Clifton, Frenchay and the city centre. The class for a laboratory door, a ward door or a drug store door is the one the fire strategy for its floor asks for. The hospital fire door rules page sets out what the schedule asks for in wards, theatres and departments.

Shops, stadiums and schools make the third group. The shops of Cabot Circus and The Mall at Cribbs Causeway, the stands and concourses of Ashton Gate Stadium and the halls and stair cores of suburban schools all carry crowds during the day, and their escape doors must stay shut in a fire yet swing open freely when people head out during a fire evacuation, and the fire door regulations for schools guide walks through a school schedule, room by room.

What a fire rating does on a steel door

The rating belongs to the whole doorset alone, since closer, hinges, leaf, frame, intumescent seals and locks passed their test as one unit. Change any part once that test is done and the rating no longer stands.

A steel door carries a fire resistance rating that runs from half an hour to two hours. E stands for integrity, which means the door keeps flames and hot gases on the fire side; EW caps radiated heat; EI adds insulation, keeping the unexposed face cooler for longer. E30 often suits a corridor door, while a riser or a stair core in a high rise block often calls for EI60 or above. The fire ratings page sets out every class in full.

Plenty of Bristol doors carry two duties at once. A riser door, a service door or a plant room door can also need a forced entry rating in addition to its fire rating. The dual certification guide explains how one doorset can hold both. The schedule details LPS 1175 Issue 8.2 (September 2024) apart from the SR2 class B3 entry, which shares its row with the fire class. The test record details BS EN 1634-1:2014+A1:2018 along with the leaf, frame and seal set that was tested, giving each class its own proof. For an opening that takes heavy daily wear, steel and timber leaf materials are compared side by side.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Rating guide for Bristol openings

Use the table as a rough guide, never as a ruling. The fire strategy for the building, with the person responsible for it, settles the class for each opening, and that decision comes ahead of any price.

Site in Bristol Opening Class to quote Door type
Office and station buildings Stair cores and risers EI60, or the class the strategy sets Fire rated steel doorset
Clinics and hospitals Theatres, wards and drug stores EI30 to EI60, seals fitted Fire rated steel door, seals fitted
Schools and universities Stair cores, laboratories and halls E30 to EI60, as the strategy sets out Fire rated steel door, glazed where needed
Ashton Gate and the shops Back of house corridors and escape doors E30 to EI60, with panic hardware Fire rated steel door, panic hardware fitted
Basements and plant rooms Stores, boiler rooms and electrical rooms EI60 or higher, as the strategy fixes it Solid fire rated steel door

How to specify a fire rated steel door in Bristol

Begin each opening with the compartment line the door sits on and the fire strategy behind it. The wall rating, together with the use of the room, settles the E, EW or EI rating for the opening. Before any price is quoted, settle the points on the specifying guide. The fire door certification guide walks through the evidence that should stand behind the class quoted.

Write leaf, frame, seals and hardware into the specification as one tested set, with the test proof for the class quoted beside them, and add the access control interface, the vision panel, the threshold and the finish, so the fitted door keeps its rating in daily use. The plant room fire doors guide covers the doors that see the hardest wear anywhere.

Where a Bristol door must carry a forced entry class beside a fire class, put both ratings on a single line of the specification. The SR2 fire doors page describes a door holding an SR2 class next to its fire rating. Gaps are covered by the fire door gaps guide, which sets out the gaps a rated door needs to stay in working order once the door is fitted.

Survey to fitted doorset in Bristol

A Bristol project starts from drawings and a door schedule that gives the class each opening needs. The survey team then measures each opening on site, looks at how the wall is built, the height of the floor and the pipes and cables that pass through the frame. The survey also records the closer and lock fitted, plus the daily traffic the door takes. From those measurements the team settles the leaf size and how the frame is fixed, and each doorset is built around the opening as measured.

That written specification is the build sheet for each doorset, and the test proof for the class quoted travels with it. Fitting works from the drawings already issued. Fitting and handover fall under the installation service. After fitting, the fire door maintenance guide explains which routine checks hold a doorset in good working order.

[email protected] is the address for drawings and the rating wanted at each opening. Expect an answer inside one working day: the specification in writing, the rating checked against the drawings and a budget range beside it.

Doors, frames and hardware across Bristol buildings

Work from the wall the door sits in, since a rating lifted from another building rarely suits a Bristol opening. Include the rating of the wall and the purpose of the room in your enquiry, and those two facts shape the specification that follows.

Questions about fire rated steel doors in Bristol

What fire rating suits a Bristol stair core door?

The building’s fire strategy settles it. A stair core door commonly takes EI60 and a corridor door E30, and the wall the door sits in makes the call between them.

Can a Bristol fire door also hold a forced entry rating?

Yes, when the doorset has passed a test for each duty. Write both ratings, fire and SR, on a single line of the specification, with test evidence behind each class.

Do Bristol hospitals and universities need fire rated steel doors?

In hospitals, universities and schools, doors on escape routes, stair cores and compartment lines commonly need a fire rating. The fire strategy for each building fixes the class.

What does a Bristol quote need?

A quote needs the wall rating with the class for each opening, and the drawings sent through the quote form. A reply arrives within a single working day, giving a checked class, a written specification and a budget range.

Looking for a fire rated steel door for a Bristol building? Send the drawings and the class for the openings you need priced. We will match a tested doorset to every one.

Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.