Certified physical security

ArxBridge
Red-brick and glass offices with steel entrance doors in Belfast

Fire · EI 30 to EI 120

Fire Rated Steel Doors in Belfast

Fire rated steel doors in Belfast for hospitals, offices and public buildings, with fire classes, closers and hardware matched to each opening.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Belfast
Prefer to talk?+44 7352 267239

Get a free quote in Belfast

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Belfast

What we supply in Belfast

More on this

A fire rated steel doorset in a Belfast hospital corridor, a university stair or a public hall has one job to do when fire breaks out, and it must do that job while people still move through the building. The leaf holds the fire back for the minutes the rating names, the frame holds the leaf in place, and the closer pulls the leaf shut each time it opens. A doorset that fits its opening gives the people inside the time the fire plan counts on.

Wards and corridors at the Royal Victoria Hospital need fire doors that close by themselves after every pass, and lecture rooms at Queen’s University Belfast plus Ulster University need stair doors that stand up to students moving between floors all day. Public rooms at Belfast City Hall sit behind heavy doors, offices and visitor spaces in the Titanic Quarter stand beside Belfast Harbour, and halls at Belfast City Airport carry travellers along the routes out. Each building asks for a doorset matched to its own opening and the people who use it.

Work opens with a survey that notes the opening size, the wall the doorset sits in, the fire rating the opening needs and how people pass through the door each day. That visit gives a written specification naming the class, the leaf, the frame, the closer and the hardware. The physical security in Belfast page covers more kinds of security across the city. Enquiries receive a written reply in one working day.

Fire classFire classes E, EW and EI for each opening
Forced entryGrades A1 to H20 on the leaf and frame
CloserClosers that pull each leaf shut on their own
ReplyAn answer in writing in one working day

A doorset matched to its Belfast opening

The leaf, the frame, the closer and the hardware are picked together, since a fire rated doorset only works when each part suits the opening it guards. A steel leaf stands up to hard daily use in a hospital corridor or a university stair, and the seals round its edge close the gap when heat rises. The fire door hardware guide walks through hinges, locks and handles for a rated leaf, and the fire door gaps guide shows why the gap round the leaf is as important as the leaf.

A closer must pull the leaf shut on its own without making the door stiff to open, and BS 8300 with Approved Document M sets the limit on opening force. A door on an escape route should open with a force under 30 N in the first 30 degrees. Beyond that point the force should stay under 22.5 N, so a person of any strength can push through it in a hurry. The access guide under Approved Document M covers the opening force and the clear width a Belfast escape route needs.

Fire classes, grades and the test behind each one

The Belfast specification exercises LPS 1175 Issue 8.2 (September 2024) exercising the grade choice against the risk at each opening, so each doorset is matched to the tools the grade is tested against. The grade scale runs A1 to H20, and one minute is SR1, three minutes SR2, five minutes SR3 and ten minutes SR4, and the grade goes into the specification beside the fire class.

The rating sits beside BS EN 1634-1:2014+A1:2018, stating E, EW and EI as the classes and 30 to 120 as the minutes. The fire ratings page names each class and what it means for the opening, and the fire compartmentation guide shows how a rated doorset holds a fire inside one part of the building. A doorset that must hold back fire and forced entry alike carries both ratings, and the dual certification guide shows how one leaf passes both tests.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Belfast buildings and the doorset each one needs

Belfast building Doorset What the survey checks
Royal Victoria Hospital Steel doorsets for ward corridors and stair doors Closers that shut after every pass, with gaps checked on each leaf
Queen’s University Belfast Steel doorsets for lecture halls and stair doors Opening force on escape routes, with hardware suited to heavy daily use
Belfast City Hall Steel doorsets for public rooms and back corridors Leaf size against the old openings, with closers set to shut the leaf
Titanic Quarter Steel doorsets for offices and visitor spaces Fire class for each opening, with the grade set by the risk at the door
Belfast City Airport Steel doorsets for halls and routes out Clear width on escape routes, with closers that never hold the leaf open

The table above names five Belfast buildings, each with its doorset and what the visit records for each door.

Martyn’s Law tiers for a Belfast site

Headcount fixes the tier for the site. Headcount puts a premises in the standard tier when 200 to 799 people are on site, and in the enhanced tier when 800 people or more are on site. The Security Industry Authority is the body named to oversee the scheme, with spring 2027 the expected start. Public rooms in City Hall and public spaces in the Titanic Quarter may fall under the law. A buyer planning doors for such a site should fix the tier from the headcount first, since the tier shapes the doors and how people get out of the building.

The guide for premises walks through the duties each tier places on a site. For the tier figures, read the Martyn’s Law standard. The fire door regulations guide for hospitals covers the hospital side of a Belfast order, while the fire door certification guide lists the papers that belong with a rated leaf.

From survey to a fitted doorset in Belfast

The job runs in order, with the survey first and the fitting last, and the rating, the written specification and supply in between. None is left out. Openings are measured during the survey, and the size, the wall and the rating are written down with how people pass through the door each day. The specification names the class, the leaf, the frame, the closer and the hardware, and no fitting starts until each item is written down. Fitting follows the specification as written, and aftercare for the doorset follows the fire door maintenance guide and the fire door inspection checklist.

Email [email protected] showing the opening sizes and the fire class each opening needs, and the reply in writing lays out the Belfast scope and what happens next.

Put the opening drawings in the post for the company Saffron Road, Romford, Essex RM5 3ES. Forward directly as soon as the drawings are posted, and the survey can be booked while the drawings are in hand.

The written specification must name the fire class, the closer and the forced entry grade, and the order holds off until each one fits the opening on the survey.

Belfast questions on fire rated steel doors

Which fire class should a Belfast steel door carry?

The class follows the fire plan for the opening. A Belfast steel door takes class E, EW or EI, and the minutes run 30 to 120. The survey records the wall, the use of the opening and the rating the plan names, and the specification carries that class before anything is ordered.

Does a fire rated steel door need a forced entry grade too?

Only where the opening faces a fire risk and a forced entry risk together. LPS 1175 runs from A1 to H20, and the minutes are one, three, five and ten across SR1, SR2, SR3 and SR4. A doorset that must meet both tests carries both ratings on the same leaf.

How does a closer change the way a Belfast fire door works?

A closer pulls the leaf shut after every pass, so the fire barrier is back in place without anyone thinking about it. The closer must still let anyone push the leaf open with ease, since the force limit stays low through the first 30 degrees and lower still beyond that point, so the leaf shuts and still opens for anyone in a hurry.

When does the written quote for Belfast fire rated steel doors arrive?

The survey records each opening, the wall, the rating and the way the door is used, and those notes set the specification. The written reply follows in one working day, naming the next step.

Ask about fire rated steel doors for your Belfast building

Give the sizes of each opening and the fire class it needs. The written quote names the class, the leaf and the fitting. Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.