Perimeter and HVM · PAS 68 and IWA 14-1
Security gates in West Midlands
Security gates for West Midlands stations, hospitals, universities and venues, with LPS 1175 grades and HVM lines matched to each site entrance.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in the West Midlands
Get a free quote in the West Midlands
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in the West Midlands
What we supply in the West Midlands
A gate stands where a site meets the street, and in the West Midlands that meeting point carries crowds, deliveries and vehicles through the same opening at different hours. Birmingham New Street station draws travellers across its forecourt morning to night, the NEC fills its gates with event traffic, and the Bullring service yard takes lorries beside the shop doors.
A security gate holds that boundary with a leaf, a frame, posts and a drive that suit the opening, and the rating follows the risk at that point rather than the size of the leaf. A sliding leaf suits a yard with no room for swing, a swing leaf suits a narrow lane where a track would clog with grit, and a side gate for people beside the vehicle leaf keeps foot traffic clear of moving metal. The sliding vehicle gate page covers the tracked form in full.
Queen Elizabeth Hospital Birmingham, the University of Birmingham and Coventry University each guard a different mix of people and vehicles, while Touchwood in Solihull, Merry Hill in Dudley and Walsall Manor Hospital add their own patterns of arrival, beside the University of Wolverhampton. This page walks through where those gates sit, the grades they carry, what a specification holds, and how the survey and the drawings come together before an order is placed. The region page gives the wider picture: physical security in the West Midlands.
Where West Midlands sites put security gates to work
Birmingham sets the pattern for the region. At New Street station, gates on the forecourt hold the line between the taxi rank and the concourse, and staff need them open for the morning rush and shut after the last train. At the Bullring, the service yard gate takes delivery lorries through the day while shoppers pass the front doors a few steps away, so leaf, drive and controls must suit both flows at once. The transport hub security requirements guide lays out the duties a station gate carries.
The NEC draws event traffic in waves, with coaches, lorries and cars arriving before a show opens, and gates there must clear a queue fast then hold shut through the event. Touchwood in Solihull and Merry Hill in Dudley face the same rhythm on a smaller scale, with shoppers arriving by car and on foot and deliveries using the rear gates. The retail sector page covers shop and mall perimeters, and the automatic vehicle barriers guide covers the barrier that often stands beside a gate.
Hospitals and universities guard people who arrive at all hours. Queen Elizabeth Hospital Birmingham needs gates that let ambulances through without delay yet hold the boundary overnight, Walsall Manor Hospital faces the same mix on a tighter site, and the University of Wolverhampton, Coventry University and the University of Birmingham each guard campuses where students, staff and delivery vans share the same entrances. The education sector page covers campus perimeters, and the healthcare sector page covers hospital boundaries.
Grades that fix what a West Midlands gate must resist
The rating table illuminates LPS 1175 Issue 8.2 (September 2024) illuminating the four grades a gate leaf and frame can carry. SR1 takes class A1 at one minute, SR2 takes class B3 at three minutes, SR3 takes class C5 at five minutes, and SR4 takes class D10 at ten minutes. The LPS 1175 standard page shows the grade table in full, and the ratings compared guide puts forced entry beside blast and ballistic for one gate.
Five gates come first in the table below, and the survey and vehicle assessment fix the grade on the final schedule for each one.
| Gate in the West Midlands | Gate build | LPS 1175 grade | Vehicle line |
|---|---|---|---|
| Forecourt gate, Birmingham New Street | Sliding leaf, rated frame | SR2, class B3 | Pedestrian gate beside it |
| Service yard gate, Bullring Birmingham | Swing leaf, rated frame | SR3, class C5 | Delivery lorries through the day |
| Event gate, NEC | Sliding leaf, wide opening | SR3, class C5 | Coach and lorry traffic on show days |
| Ambulance gate, Queen Elizabeth Hospital | Swing leaf, fast drive | SR2, class B3 | Clear lane for emergency vehicles |
| Campus gate, University of Birmingham | Sliding leaf, rated frame | SR2, class B3 | Students and vans share the entrance |
PAS 68:2013 went out of use on 25 October 2023. The rating now sits with ISO 22343-1:2023 instead, and the schedule names the new standard. On a hostile vehicle line, the clear gap runs to 1,200 mm at most and the height to 500 mm at least, and the vehicle impact ratings page shows every class in the list. The anti-ram gates and barriers page covers gates built to stop a vehicle, and the choosing HVM bollards guide covers bollards that close the gap beside a gate.
For a pedestrian gate beside a vehicle leaf, BS 8300 puts the push limit at 30 N while the gate swings through its opening 30 degrees, then at 22.5 N past that point. The security bollards page covers the posts that guard a gate line, and the hostile vehicle mitigation page covers the full line.
What a West Midlands gate specification holds
The opening itself comes first: measure the clear width between the posts, note the ground levels on both sides, and note where power sits for the drive. A forecourt gate busy all day and a rear yard gate shut through the night need different drives, and the specifying security doors page goes over the choices that come before a price is fixed. The automatic gates cost factors guide shows what pushes the figure up or down, from the width of the leaf to the type of drive.
The leaf form follows the ground: a tracked leaf needs a clear run and a level threshold, while a hinged leaf needs swing room clear of parked cars. Frame and fixings must suit the leaf, since a leaf that beats its frame earns no rating. The ten steps page runs over the same choices in order for a rated leaf.
Access and safety close the specification. Readers, intercoms and loops must suit daily flow, and a gate shut overnight needs a lock that keeps shut with no power. Busy sites shape the access in the same way. Martyn’s Law tiers, expected in spring 2027, split at 800 people: places with 800 or more people go in the enhanced tier, while places with 200 to 799 people go in the standard tier. The Martyn’s Law standard page gives the duties each tier carries for a site.
Measuring and drawing each West Midlands gate
Each gate position is measured where it stands before the schedule is written. The surveyor records the clear width, ground levels, post positions and power points for every gate, then notes the turning room for vehicles and the path beside the leaf. Photos and sketches of each opening go into the job file, and the schedule follows those notes.
Survey notes stay at our West Midlands buttery Saffron Road, Romford, Essex RM5 3ES. Send them with each gate leaf size, so the grade sits beside its own drawing in the folder.
Write to [email protected] to plan each gate with its width, grade and drive type, and a written answer comes back within one working day.
Final checks before the gate is ordered
Check the turning room beside each gate before the grade is set. A leaf that swings into a footpath or a track that fills with grit slows the gate down, so the ground beside the opening fixes the leaf form.
Run through the schedule once more before the order goes in: each gate with width, grade, drive and access control, and each pedestrian gate beside its vehicle leaf. The acceptance and snagging guide goes through the checks to run when the gate arrives on site, and the cover for worn parts is described in the warranty, defects and guarantees guide.
West Midlands buyers ask about security gates
Which gate leaf suits a tight service yard?
A tracked leaf fits a yard with no room for swing, since it runs along the fence line and leaves the yard clear. A hinged leaf needs clear ground on one side, so it fits a lane with room.
Does an LPS 1175 grade prove a gate stops a vehicle?
No. A forced entry grade proves leaf and frame resist attack for a set time, and a vehicle rating proves the line stops a vehicle, so a gate facing both duties needs both ratings on the schedule.
What happens when the leaf beats the frame?
The frame gives way first. Frame, leaf and fixings go through testing as one unit, so a leaf that beats its frame takes no rating on its own. Frame and fixings go on the schedule beside the leaf, so no weak point stays unseen.
What care does a security gate need in daily use?
A booked visit starts the care. The drive, track and fixings are checked first, then the lock and access control, and parts that show wear are swapped out before they break. The security door maintenance checklist holds checks for a gate in daily use.
Security gates on a West Midlands site?
Share the width, grade and drive type of each gate, and leaf, frame and fixings are priced as a single unit together. Get a free quote
Other areas
Security gates in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.