Perimeter and HVM · PAS 68 and IWA 14-1
Security Gates in London
Security gates for London yards, schools, hospitals and data centres, with LPS 1175 and ISO 22343-1 ratings, automation and a written specification.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in London
Get a free quote in London
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in London
What we supply in London
A gate is the point where a London site decides who and what may enter. Yards and depots in Park Royal and Dagenham, schools and hospitals across the boroughs, car parks under housing estates, and data centres on the edge of the city all rely on a gate that opens for the right vehicle, stays shut for the rest, and holds its line when it is pushed, rammed, or climbed.
Security gates cover that point in several forms. A swing gate suits a shorter entrance with clear space to open, a sliding vehicle gate suits a long boundary where the leaf has space to run back, a cantilever gate suits a yard where the ground cannot carry a track, and a pedestrian gate beside the vehicle lane keeps staff and visitors on a separate, controlled route. The form follows the width of the entrance, the ground, the traffic, and the rating the site needs.
London adds its own pressures to that choice. Entrances sit close to pavements and bus routes, space for a gate to run back is often short, and delivery traffic arrives through the day. The specification should settle the gate type, the rating, the automation, and the safety devices together, before the groundwork starts.
Where London sites need security gates
Logistics yards, builders merchants, and depots around Park Royal, Wembley, Dagenham, and Heathrow cargo need gates that take heavy vehicles all day. A sliding gate on a track suits a wide yard entrance, while a cantilever gate suits a yard where the track would fill with grit and water. The gate leaf, the posts, and the foundation carry the rating, and the London area page maps how those areas sit beside housing and offices across the capital.
Schools, hospitals, and housing estates need a different balance. A school gate must let pupils, staff, and deliveries through at set times and stay shut between those times, while a hospital gate must keep an ambulance route clear at all hours. A separate pedestrian gate beside the vehicle lane keeps staff and visitors apart from vehicles, and the pedestrian gates guide explains how the two lanes are planned together.
Offices, data centres, and utility compounds in the City, Canary Wharf, and outer London business parks need gates that match the fence line and the door schedule. A data centre gate sits beside bollards and fencing on the same boundary, and a substation gate must allow maintenance vehicles in while keeping the compound shut at other times. Security bollards beside the gate close the gap a vehicle could use to pass around it.
Ratings that govern security gates in London
Gates take their forced entry rating from LPS 1175 Issue 8.2 (September 2024). That standard grades doors, gates, and grilles SR1 to SR5, each class tied to a named set of tools and a set attack time. A yard gate that only faces hand tools can sit at a lower class than a gate guarding a cash room or a control room. The LPS 1175 standard page lists every SR class, and the LPS 1175 gates and grilles guide shows how those classes read against a gate leaf and its posts.
Vehicle impact ratings sit on a separate scale. ISO 22343-1:2023 now governs vehicle security barriers, and gates rated against a vehicle impact take their class from it. PAS 68:2013 was withdrawn in October 2023, so a buyer should ask for the ISO 22343-1 class, the vehicle weight, the speed, and the penetration distance in the same document, rather than accepting a PAS 68 class as current. The vehicle impact ratings page carries the current scale.
Automation adds a safety standard of its own. A powered gate should have safety edges, photocells, and a force limit that stops the leaf when it meets a person or a vehicle, and the controls should fail safe so a power cut leaves a clear exit route where people need one. The gate automation guide explains the safety devices a London gate should carry, and the security gates cost factors guide sets out what sets the price of a gate.
| London site | Gate form | Rating to ask for | Control |
|---|---|---|---|
| Logistics yard | Sliding or cantilever vehicle gate | LPS 1175 SR2 or SR3 | Intercom and keypad |
| School or hospital | Vehicle gate with pedestrian gate | LPS 1175 SR2 | Access control and timed opening |
| Data centre or utility compound | Sliding vehicle gate, high fence line | LPS 1175 SR3 | Card reader and CCTV link |
| High vehicle threat site | Vehicle gate with barrier | ISO 22343-1 vehicle class | Intercom and barrier control |
| Housing estate car park | Swing or sliding vehicle gate | LPS 1175 SR2 | Fob reader and intercom |
How to specify security gates in London
Start with the entrance itself. Measure the clear width, the height, the space for a sliding leaf to run back, and the swing arc for a hinged leaf, and check the ground for a track, a foundation, and drainage. A narrow London street with a pavement close to the boundary often rules out a swing gate that opens outward, and a yard with no run back room rules out a sliding gate on a track, which leaves a cantilever gate as the practical form.
Next, settle the rating and the infill. A solid leaf hides the yard and resists climbing, a barred leaf lets staff see through and suits a school or a car park where sight lines matter, and a mesh infill suits a depot where air and light are needed. The leaf, the posts, the hinges or rollers, and the lock should come with test evidence for the same SR class, because a strong leaf on weak posts has no tested rating as a gate. Sliding vehicle gates show the form that suits the widest London yard entrances.
Then settle the automation and the access control. A gate motor should match the weight of the leaf and the number of cycles a day, with safety edges and photocells that stop the leaf on contact, and a manual release for a power cut. Card readers, fobs, intercoms, and number plate readers each suit a different flow of users, and the warehouse security gates guide explains how a busy yard plans the vehicle and pedestrian lanes together.
Project steps for security gates in London
Work begins at the entrance itself, with a survey of the gate position. The surveyor records the opening, the ground levels, the space for the leaf to move, the power supply, and the drainage, and notes the pavement and any planning limits on height or on a gate that opens onto a public highway. Photographs and a sketch of the boundary give the specification a firm footing to work from.
Next the rating and the gate form go into the written record: SR class or ISO 22343-1 vehicle class, leaf size, infill, automation, and access control, all named for that entrance. The perimeter range holds the gate, bollard, and barrier forms that record can draw on, and evidence for the rated gate is handed over with the gate, so the buyer can match the class claimed against the class actually tested.
Groundwork comes before the gate leaf, with foundations, ducts for power and data, and drainage laid to the surveyed levels. Servicing, done by our own team or by our installation partners, starts from the written specification and the surveyed dimensions. Send the entrance drawings and the rating you need to [email protected] by email. The quote form on the site takes the same details, and the reply brings a written specification with a budget range inside one working day.
Measure the run back before choosing a sliding gate. A leaf with no room to slide open is a gate that cannot be used, and the survey should settle the form before the foundation is dug.
Questions about security gates in London
Should a London yard choose a sliding gate or a swing gate?
The entrance decides. A sliding gate fits a wide entrance where the leaf has space to run back beside the fence, while a swing gate fits a shorter entrance with clear space to open inward. A narrow street with a pavement close to the boundary often rules out a gate that swings outward onto the highway.
Do security gates in London need planning permission?
It depends on the height, the position, and whether the site is listed or in a conservation area. A gate beside a highway above a set height can need permission, and a listed building needs consent for a change to its boundary. The survey should check the local rules before the specification is fixed.
What happens to a powered gate in a power cut?
A powered gate should have a manual release that staff can use, and the controls should fail safe so people can leave the site. The specification should name the release method and the fail safe state, and staff should be shown how to use the release when the gate is handed over.
Planning security gates for a London site? Share the entrance sketch and the rating the gate needs.
Other areas
Security gates in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.