Perimeter and HVM · PAS 68 and IWA 14-1
Security Gates in Nottingham
Security gates for Nottingham hospitals, universities, arenas and retail sites, with LPS 1175 ratings, automation, safety devices and a written specification.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Nottingham
Get a free quote in Nottingham
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Nottingham
What we supply in Nottingham
At Queen’s Medical Centre the vehicle lane must never block an ambulance. At Motorpoint Arena Nottingham it must swallow a crowd of coaches and cars, then shut again. At the University of Nottingham and Nottingham Trent University it must let staff, students, and deliveries through on a timetable. One gate, three rhythms, and the rating, form, and controls have to fit the rhythm of the site, not the other way round.
Security gates give a Nottingham buyer several ways to do that. A slim foot gate next to the vehicle lane keeps people clear of lorries, a sliding panel needs a straight stretch of boundary to disappear into when it opens, a swinging panel turns inward where the opening is short, and a cantilever panel stays clear of the ground where a track cannot sit. Opening width, ground, traffic through the day, and the rating the site must meet settle the choice.
Nottingham streets tighten the choice. Entrances near the Lace Market and Nottingham railway station sit close to pavements and bus routes, room for a panel to run back is often short, while delivery vehicles keep arriving through the day. East Midlands Airport serves the city but sits in Leicestershire, so freight and staff routes from the airport cross the city rather than starting inside it. Put gate type, rating, automation, and safety devices in one paper before any groundwork starts.
Nottingham places that ask for a security gate
The hospital and the two universities run on timetables. Queen’s Medical Centre needs its vehicle lane clear at every hour, with a foot gate that keeps visitors away from moving vehicles and controls that let staff open the gate fast for an emergency vehicle. The University of Nottingham and Nottingham Trent University need gates that open for staff, students, and deliveries on a timetable and stay shut between those times. The physical security in Nottingham page carries the wider city picture.
Retail, arena, and depot sites run on lorries and crowds. Victoria Centre and Broadmarsh take deliveries through service yards close to shoppers, Motorpoint Arena Nottingham needs its vehicle lanes open for an event and shut again once the crowd has gone, and depots on the freight routes from East Midlands Airport take heavy vehicles in poor light. For the forms that fit beside a gate, see the security bollards page, which blocks a vehicle from passing round the end of a gate. For a busy yard layout, see the warehouse security gates guide. The pedestrian gates guide covers how the vehicle lane and the foot lane are planned side by side.
What a Nottingham gate rating has to prove
A forced entry rating names what a gate resists and for how long. The SR class chosen alongside LPS 1175 Issue 8.2 (September 2024) requires test evidence for the panel, posts, and lock together, not for the panel alone. SR1 stands at A1, SR2 at B3 with three minutes, SR3 at C5, SR4 at D10, each class tied to its own named tool set. The LPS 1175 standard page lists every class. For the classes applied to a panel and its posts, see the LPS 1175 gates and grilles guide.
For vehicle impact, ISO 22343-1:2023 is the current scale, and a gate built to stop a vehicle takes its class there, with weight, speed, and penetration distance all named in that paper. PAS 68:2013 ended in October 2023, so an old PAS 68 figure should no longer be accepted as current. The scale now in use is laid out on the vehicle impact ratings page. Powered panels need edges and photocells that halt them on contact, a force limit, and controls that open the way out when the power drops. The gate automation guide covers those devices, and the automatic gates cost factors guide covers what sets the price of a powered gate.
The five rows here match each Nottingham site type with its gate form, rating, and control.
| Site | Form | Rating | Control |
|---|---|---|---|
| Depot on freight route | Cantilever gate | SR3 (LPS 1175) | Fob reader first, intercom |
| Motorpoint Arena | Wide gate, barrier alongside | ISO 22343-1 vehicle class | Barrier control and intercom |
| Queen’s Medical Centre | Vehicle gate plus foot gate | SR2 (LPS 1175) | Intercom and ambulance priority |
| Victoria Centre, Broadmarsh | Sliding or cantilever gate | SR2, SR3 (LPS 1175) | Intercom and keypad |
| University campus | Sliding gate with foot gate | SR2 (LPS 1175) | Card reader and timed opening |
Setting the specification for a Nottingham gate
Begin by measuring the mouth of the site. Note the clear width and height, how far a sliding panel can travel, the swing arc of a hinged panel, and whether the ground can hold a track, a foundation, and drainage. A pavement hard against the boundary near the Lace Market often rules out an outward swing, and a yard with no travel room leaves a sliding panel on a track out of the question, so a cantilever panel is the workable form.
Infill is a security choice as well as a look. Solid panels hide what sits behind the gate and give a climber nothing to grip, bars keep sight lines open for staff watching a campus or a car park, and mesh lets air and light through a depot while still closing the opening. Whatever the infill, the rating must be proved for the whole gate at once: panel, posts, hinges or rollers, and lock, each covered by the same SR class test papers, since the rating belongs to the whole gate, not to the panel alone. The sliding vehicle gates page shows the form for the widest Nottingham yard mouths.
The drive must suit the panel weight and the daily cycle count. Fit safety edges and photocells that stop the panel on contact with a person or a vehicle, and a hand release so staff can open the gate when power fails. Intercoms, plate readers, card readers, and fobs each fit a different flow of users. The anti-ram gates and barriers guide walks through how a gate and a barrier act together where the vehicle threat is high.
The order of work on a Nottingham gate
The job opens with a visit to the gate position. The visitor measures the opening, checks ground levels, the space the panel needs to travel, the power supply, and the drainage, then the pavement and any height limits or rules on gates opening onto a public road. Photos and a measured sketch then anchor the paper that follows.
The paper then records the rating and the form for that entrance: panel size, infill, automation, access control, and SR class, or an ISO 22343-1 vehicle class, each named for the opening it belongs to. Gate, bollard, and barrier forms for the paper sit in the perimeter range, and the rated gate is delivered with its evidence, so the class on the paper can be matched to the class in the test evidence.
Power and data ducts, foundations, and drainage go in before the panel, laid to the surveyed levels. It is checked against the drawing before it leaves the workshop. Email [email protected] with a sketch of the entrance plus the rating the gate needs, or put the same details in the quote form on the site. A written answer follows within one working day, with the specification and a budget figure for that gate.
Check the ground for a track before choosing a sliding panel. A track that fills with grit and water will jam, and the visit should settle the form before any foundation is dug.
Answers for Nottingham gate buyers
Should a Nottingham depot choose a cantilever gate or a sliding gate?
The ground decides. A cantilever panel suits a depot where a track would fill with grit and water, while a sliding panel on a track fits a yard with a long, level stretch beside the fence. The visit measures the opening and the ground, and the form follows those figures.
Does a foot gate need the same rating as the vehicle gate?
The rating for a foot gate fixed alongside LPS 1175 Issue 8.2 (September 2024) requires the same care, since a weak side gate leaves the main gate pointless. Both panels should carry test evidence for the class the site needs, with posts and locks tested to match.
What happens to a powered gate in Nottingham when power fails?
Fit a hand release staff can reach, with controls that open the exit when the power drops. Write the release method into the paper and show staff the release at handover.
Can a gate swing outward onto a Nottingham pavement?
A panel that swings outward onto a public road or pavement can need planning permission, and a listed building boundary change needs consent. Sort height, position, and local rules at the visit, before anything is fixed in the paper.
Tell us about a Nottingham entrance: how wide the opening is, what the ground is like, and the rating the gate must meet.
Other areas
Security gates in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.