Perimeter and HVM · PAS 68 and IWA 14-1
Security Gates in Edinburgh
Security gates for Edinburgh yards, hospitals, universities and depots, with LPS 1175 ratings, automation, safety devices and a written specification.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Edinburgh
Get a free quote in Edinburgh
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Edinburgh
What we supply in Edinburgh
Lorries serving Leith docks, ambulances turning into the Royal Infirmary of Edinburgh, students crossing the University of Edinburgh campus, and coaches setting down near the Royal Mile all meet the same question at the boundary: does this vehicle belong inside, and does it belong inside now. A gate answers it, opening for the right arrival and staying shut for the rest.
Security gates take several shapes for that job. A panel that slides runs back beside the fence on a long boundary, a panel that swings turns inward where the opening is short, a cantilever panel hangs clear of the ground where no track can sit, and a slim foot gate beside the vehicle lane keeps people out of the path of lorries. Width, ground, daily flow, and the rating the site must meet decide between them.
Edinburgh adds stone, slope, and weather to the decision. Old Town lanes leave little room for a panel to travel, boundaries sit close to pavements, and wind off the Forth with rain through the winter works on hinges, rollers, and motors. A gate that behaves on a calm day in a yard can still stick on a wet night at a dock, so form, rating, automation, and safety devices belong in one paper before groundwork starts.
Where Edinburgh sites put security gates
Leith docks and the freight routes around Edinburgh Airport carry the hardest use. Lorries arrive through the day, often in poor light, and the gate there must open fast, close firm, and keep working when grit and water gather at the base. A cantilever panel suits a dock mouth where a ground track would clog, while a sliding panel suits a yard with a long, level run back. The physical security in Edinburgh page carries the wider city picture.
Hospitals, campuses, and event venues ask for a different balance. The Royal Infirmary of Edinburgh needs an ambulance route clear at every hour, Edinburgh’s two universities need gates that admit staff, students, and deliveries at set times, Festival venues need a gate that handles a surge of visitors and then shuts the site again, and Murrayfield Stadium needs vehicle lanes that open for event traffic and close for the rest of the week. A foot gate beside the vehicle lane keeps people away from lorries, and the pedestrian gates guide covers how the two lanes are planned side by side. The security bollards page covers the forms that fit beside a gate, shutting the way round the end of a gate.
Ratings behind an Edinburgh gate
Forced entry ratings give a buyer one language for what a gate resists. The rating scale set out across LPS 1175 Issue 8.2 (September 2024) states SR1 as the lowest class, with SR2 at B3 and three minutes, SR3 at C5, and SR4 at D10. A depot gate facing hand tools can sit lower than a gate guarding a control room or a cash store. The LPS 1175 standard page lists the classes. The LPS 1175 gates and grilles guide walks through the way each class applies to a panel with its posts.
Vehicle impact and automation sit on their own scales. Vehicle security barriers now follow ISO 22343-1:2023, so a gate that must stop a vehicle takes its class from that scale, with weight, speed, and penetration distance named in the same paper, and PAS 68:2013, withdrawn in October 2023, should no longer be accepted as current. For the current scale, see the vehicle impact ratings page. A powered panel also needs safety edges, photocells, a force limit, with fail safe controls so people can leave when power drops, and the gate automation guide covers those devices. What fixes the price of a gate is set out in the security gates cost factors guide.
Five Edinburgh site types, each with a gate form, a rating to request, and a control method, appear in the rows below.
| Site | Form | Rating | Control |
|---|---|---|---|
| University campus | Sliding gate, foot gate | LPS 1175 SR2 | Timed opening, card reader |
| Leith docks | Cantilever gate | LPS 1175 SR2, SR3 | Intercom, keypad |
| Royal Infirmary | Gate pair: vehicle and foot | LPS 1175 SR2 | Ambulance priority, intercom |
| Financial district office | Swing gate | LPS 1175 SR2, SR3 | Intercom, fob reader |
| Festival venue, Murrayfield | Wide gate and barrier | ISO 22343-1 vehicle class | Barrier control, intercom |
How to set out an Edinburgh gate specification
Measure the opening first. Take the clear width and height, the room for a sliding panel to run back, the arc for a hinged panel, and the ground, whether it will take a track, a foundation, and drainage. A lane near the Royal Mile with a pavement hard against the boundary often rules out a panel that swings outward, and a dock yard short on run back room rules out a sliding panel on a track, which leaves a cantilever panel as the workable form.
Fix rating and infill in the same pass. An opaque panel blocks the view into the yard and resists climbing, a barred panel lets staff see through and fits a university ground or a parking area where a clear view through matters, and a mesh panel fits a depot where air and light are wanted. Panel, posts, hinges or rollers, and lock need papers that prove one SR class for the whole gate, since a strong panel on weak posts holds no tested rating. The sliding vehicle gates page covers the form for the widest Edinburgh yard mouths.
Fobs, intercoms, plate readers, and card readers each match a different flow of users. Pick a drive rated for the panel weight and the number of openings a day, fit safety edges and photocells that halt the panel on contact, and add a release handle for a power cut. The warehouse security gates guide covers how a busy yard lays out its vehicle and foot lanes together.
From first visit to fitted gate in Edinburgh
A visit to the gate position opens the job. The visitor notes the opening, the ground levels, how far the panel can travel, the power supply, and the drainage, plus the pavement and any local limits on height or on a gate opening onto a public road. Photos plus a measured sketch of the boundary give the paper a firm base to work from.
Next the paper records the rating and the form, with ISO 22343-1 vehicle class or SR class, panel size, infill, automation, and access control set down for that one entrance. The perimeter range holds forms for gates, bollards, and barriers that the record can draw on, and the tested gate is handed over with the papers that prove it, so the buyer can match the class on the order with the class in the test papers.
Ducts for power and data, foundations, and drainage run before the panel, laid to the levels the visit recorded. Posts are set square and the panel is hung to the surveyed dimensions. Email the sketch of the entrance and the rating the gate needs, addressed to [email protected], or put those particulars in the quote form on the site. The buyer gets a written reply inside one working day, carrying a specification and a budget figure for the entrance.
Settle the run back before choosing a sliding panel. A panel with no room to travel open can never be used, so the visit should fix the form before the foundation is dug.
Edinburgh gate questions answered
Which gate form suits a Leith dock mouth?
A cantilever panel often suits a dock mouth, because a ground track fills with grit and water and a sliding panel needs a long, level run back. The visit measures the opening, the ground, and the space beside the fence, and the form follows those figures rather than habit.
How long does each LPS 1175 class resist attack?
The attack time scale set out across LPS 1175 Issue 8.2 (September 2024) states the minutes each class must resist, so a buyer can match the class to the risk at the entrance. SR2 sits at three minutes with a B3 tool set, while SR3 and SR4 face heavier tool sets and longer times.
What keeps a powered gate safe when power fails?
Fit a release handle staff can reach, and set the controls to fail safe so the exit stays open when power drops. Put the release method in the paper and walk staff through it at handover.
Does a gate beside a listed Edinburgh building need consent?
Height, position, and listing decide. A gate beside a road over a set height can need permission, and consent is needed for a change to a listed building boundary. Check the local rules at the visit, before the paper is fixed.
Talk through an Edinburgh entrance with us: send the opening width, the ground, and the rating the gate must meet.
Other areas
Security gates in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.