Certified physical security

ArxBridge
Port-side commercial buildings with steel doors in Southampton

Services

Installation in Southampton

Installation in Southampton for security doors, shutters, gates and barriers, from survey and written specification to fitting, testing and handover.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Southampton
Prefer to talk?+44 7352 267239

Get a free quote in Southampton

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Southampton

What we supply in Southampton

More on this

Fitting a security door in Southampton starts long before the leaf arrives on site. The opening is measured, the wall round it is checked, and the hardware is picked to suit the leaf and the cycles it will see each day, so the fitting day itself runs in order and the door is tested before it is handed over.

An installation covers the whole sequence, from the first site measure and the written specification, through the fitting of leaf, frame and hardware, to the tests and the handover record that close the job. Each step is written down as it happens, so the record for the opening matches the door that stands in it.

Southampton General Hospital, the University of Southampton, Southampton Central station and the port each ask for a different sequence. A hospital corridor stays in use through the work, a university hall empties between terms, and a station entrance moves travellers all day, so the physical security in Southampton page looks at the protection of those sites as a whole, from the gate at the boundary to the rooms inside.

Hospital corridorsWards and departments in use through the work
University hallsHalls and libraries fitted between terms
Station and portEntrances that move travellers all day
Written handoverTests and records for every opening

How an installation in Southampton is sequenced

At Southampton General Hospital, work is planned round wards and departments that run day and night. The opening is measured first, then the leaf and frame are fitted in a window agreed with the ward, and the door is tested before the corridor returns to full use, with the healthcare sector page looking at ward and department doors across a hospital site.

The University of Southampton and Solent University give a different window, with halls and libraries that empty between terms and fill again for the new term. Southampton Central station gives no such window, since travellers pass through the day, so the fitting there is staged round the quieter hours, and the transport hub security requirements page covers doors and barriers round a station.

At the port, the sequence follows the movement of freight and passengers. An entrance lane is closed in turn while the next lane stays open, so the port keeps moving while each door is fitted and tested. The lead times and programme risks page explains how a programme is planned when doors arrive in stages.

Grades and records behind a Southampton installation

The Southampton schedule houses LPS 1175 Issue 8.2 (September 2024) housing the forced entry grade for every opening, with the fire and access duties the door must also meet beside it. The grades run in order of hold time. SR1 takes class A1 with a hold of one minute, SR2 takes class B3 with a hold of three minutes, SR3 takes class C5 with a hold of five minutes, and SR4 takes class D10 with a hold of ten minutes. Every grade is set out with its tools and hold time on the LPS 1175 page.

The table pairs five Southampton openings with the sequence each one asks for. The sequence that goes on the schedule is settled by the survey and the written specification.

Opening in Southampton Sequence Test at the end Grade
Ward door, Southampton General Hospital Measured, fitted in an agreed window Closer, lock and seals checked SR2, class B3
Hall door, University of Southampton Fitted between terms Access control and closer tested SR2, class B3
Library door, Solent University Fitted between terms Reader and closer tested SR2, class B3
Station entrance, Southampton Central Staged round quieter hours Leaf, frame and reader checked SR3, class C5
Terminal door, Port of Southampton One lane at a time Access control and seals tested SR3, class C5

Every opening is tested before handover. The leaf is checked in its frame, the lock and closer are worked through their cycles, and the access control is tried with the cards and codes the building will use, so the door that is handed over is the door that was tested. The installation handover guide covers the handover record for a rated doorset, and the acceptance and snagging page covers the checks that close a job.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

What goes into a Southampton installation specification

The specification starts with the opening itself. Width, height, wall build and swing are written down first, then the grade for the opening, then the hardware that suits the leaf and how often it opens each day. The how to specify security doors page puts those choices in order for a rated doorset.

Leaf, frame and glazing are chosen together, since the rating belongs to the whole doorset and not to the leaf alone. A glazed leaf lets staff watch who is outside, while a solid leaf suits a plant room or a staff entrance, and the fixings that hold the frame have to suit the wall they sit in.

The last choices are hardware and access control. The lock, hinges and closer are sized for the leaf and how often it opens each day, and the reader is placed where staff can reach it without blocking the corridor, with the ten steps for a rated LPS 1175 doorset page setting out the steps for a rated doorset.

Survey and drawings in Southampton

The surveyor measures every opening on site before the specification is written. Width, height, wall build and swing are recorded for each opening, then the power points and access points are noted beside the paths staff and visitors follow between areas, and sketches and photos of each opening are filed with the record.

Job drawings are kept at our Southampton bandstand Saffron Road, Romford, Essex RM5 3ES. Visit them with the surveyor on the first fitting day, so each opening is checked against its own drawing before work starts.

Write to [email protected] during office hours with the sizes of the openings and the grade each one needs, and we reply within one working day to agree the survey date.

A final check before the fitting day

Fix the order of the openings before the fitting day, since a hospital corridor and a station entrance ask for different windows, and the sequence has to follow the building that stays in use while the work runs.

Questions buyers in Southampton ask about installation

How long does a door fitting take?

It follows the opening. A plain leaf in a sound frame is fitted and tested in one visit, while a glazed leaf or a reader that needs new wiring can call for a second visit, and the programme for a full schedule is agreed before work starts, so each opening has its own window.

Does the building stay open while doors are fitted?

Yes, where the work allows it. A hospital corridor or a station entrance is fitted in stages, with one lane or one leaf closed at a time, so people keep moving while the work runs, and a room that must stay shut is agreed with the building before the fitting day.

What gets checked at handover?

The checks cover the leaf in its frame, the lock and closer through their cycles, and the access control with the cards and codes the building will use. The checks are written on the handover record, with the grade for each opening beside its drawing, and the commissioning and handover manual page covers the records that close a job.

How is a fitted door looked after once it is running?

A planned visit comes first, where hinges, lock and closer are checked in turn, and a part that shows wear is swapped out before it gives way. The checks a door in daily use needs are listed on the security door maintenance checklist page, and the warranty, defects and guarantees guide covers a part that wears out.

Installation for a Southampton site?

Send each opening size with the grade it needs, and the leaf, frame and hardware are priced together as one doorset. Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.