Blast · ISO 16933 EXV45 to EXV10
Blast resistant doors in Sheffield
Blast resistant doors in Sheffield for hospitals, universities, arenas and factories, rated to ISO 16933 with a survey, written specification and install.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Sheffield
Get a free quote in Sheffield
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Sheffield
What we supply in Sheffield
A blast resistant door in Sheffield is ordered for one opening where a blast load forms part of the risk at that doorway. The test covers the leaf, frame, hinges and lock together as one doorset, so the whole assembly holds under the load its mark names. Buyers across the city order them for hospital doorways, university plant rooms, arena service entries, retail stock rooms and factory gates, and every order begins with the size of the opening and the mark the site needs.
Sheffield pairs heavy industry with hospitals, campuses and big public venues, and each kind of site puts a blast door in a different spot. The Advanced Manufacturing Park and Sheffield Forgemasters guard works entries, stores and control rooms where forklifts and lorries pass all day, while the workshops and small factories around Kelham Island and Attercliffe guard street doors that open straight onto the pavement. Sheffield Children’s Hospital and the Royal Hallamshire Hospital keep plant rooms, stores and service corridors behind rated leaves through the day and night, because those rooms sit beside public entrances used at all hours, and Northern General Hospital, on the north edge of the city, asks for the same protection on its own plant rooms and stores.
Sheffield Hallam University protects teaching blocks and laboratories spread between the centre and the western suburbs. The University of Sheffield asks for the same protection on its own plant rooms and teaching blocks. Meadowhall, The Moor and Fargate put rated leaves on stock rooms, cash offices and service corridors behind shopfronts that stay busy through the day. Utilita Arena Sheffield, Bramall Lane and Hillsborough draw big crowds on match and event days, so their service and plant room doors see heavy use on a few days each year. Crowds pass through the entrances at Sheffield station from the first train of the day, and the workshops along Ecclesall Road add more street doors that face the pavement. Wider city detail sits on the Sheffield area page, and the glazed or solid guide covers the first choice a buyer makes.
Where Sheffield sites need a blast door
Hospitals and universities put blast doors where a service corridor, a store or a plant room stands beside a public entrance. Boilers, switchgear and medical gas stores fill a hospital plant room, so a rated leaf at that room keeps the plant behind a tested doorset while staff pass through it during a normal working day. Laboratories and stores at the universities hold equipment and chemicals, so the door on such a store holds the contents behind a leaf tested together with its frame and hardware. The hospital doors guide and the university doors guide both name the rooms where a rated leaf earns its place.
Retail, leisure and factory sites put the same door in other spots. Meadowhall and the shops on The Moor and Fargate fit rated leaves to stock rooms, cash offices and service corridors, while Bramall Lane, Hillsborough and Utilita Arena Sheffield fit them to plant rooms and service doors that open onto public concourses. The works around Attercliffe and Sheffield Forgemasters fit them to stores and control rooms, and Sheffield station fits them to plant rooms and staff areas behind the public concourse. The stadium doors guide names which rooms at a ground call for a rated leaf.
Ratings that fix the door
What fixes a blast rating is the standard and the load its test applied, not the look of the leaf. Most buyers in Sheffield meet two marks from ISO 16933: EXV, from a vented test, and SB, from a test where the leaf stays in the frame. The EPR and EXR marks come from EN 13123 with EN 13124 for the same kind of opening. The specification references LPS 1175 Issue 8.2 (September 2024) against which each door is tested. Write the rating into the order in full, standard and mark together, and the door supplied is one tested to that mark and nothing else.
| Mark | Standard behind it | Where it applies |
|---|---|---|
| EXV | ISO 16933 | Vented test; leaf may leave the frame |
| SB | ISO 16933 | Leaf stays in the frame under the load |
| EPR, EXR | EN 13123 and EN 13124 | Blast test and classification of the doorset |
| FB1 to FB7, FSG | EN 1522 and EN 1523 | Ballistic resistance of the same doorset |
| SR1 to SR4 | LPS 1175 | Delay against forced entry on the same doorset |
Whether EXV or SB fits turns on what sits behind the door and how the building is used. An empty store or plant room calls for a different mark than an entrance staff pass through all day, and a door that also needs a forced entry rating takes an SR mark alongside the blast mark, drawn from the LPS 1175 scale. The EXV or SB guide puts the two marks side by side, the blast rating scale page gathers the marks in one place, and the blast ratings guide shows where a blast mark, a ballistic mark and a forced entry mark part company.
How to specify a blast door for a Sheffield opening
A sound specification starts with the opening itself. The visit measures the clear width and height, records the wall build, then the floor level and the threshold step, and notes the hanging side and the way the room is used across the day. A plant room door needs a threshold that lets trolleys and cable drums pass, a stock room door needs a lock staff can work quickly when the shift ends, and a door onto a public concourse needs panic hardware that opens under pressure from inside. Each of those points goes into the written specification before a price is fixed, so the door supplied fits the opening it was made for. The specify security doors guide runs through the measurements and the hardware points in order, and the plant room door guide covers the threshold and hardware points for plant rooms.
The finish is fixed at the same time as the rating. A steel leaf takes primer and powder coat in a colour that suits the room, the frame takes the same coat, and the seals sit so the leaf shuts tight on the frame each time it closes. The check covers the lock, the hinges and the closer, with a written record for the buyer.
Where staff need to see through the doorway, a glazed leaf fits; where the room holds plant or stock, a solid leaf fits. Each is tested as one set with its frame and hardware, so the room decides the choice, not the leaf on its own.
What the project looks like
The project runs in five steps. The opening is surveyed for sizes and rating, the written specification sets down the standard and the mark, the hardware and the finish, the door is built to those sizes, the fit happens on dates agreed with the site, and a last test of leaf, lock and closer closes the job. Send the details to the Romford office, Saffron Road, Romford, Essex RM5 3ES, so the team can price the job from those sizes.
Send the full opening measurements to [email protected]; expect our written answer within one working day, naming the rating the survey fixed and the price for the job. That answer also carries the fitting programme and the dates, so the site team can book the work around other trades from the first exchange.
Questions buyers in Sheffield ask
Do I need a blast rating or a forced entry rating?
A blast rating answers a blast load on the doorset, while a forced entry rating answers delay against hand tools, so the two cover different risks. A plant room or store door often needs both marks, and the specification states each one in full so the test behind each mark stays clear. The survey settles which marks the opening needs.
Does a blast rated door allow a glazed panel?
It can, when the mark covers glazing. The glazed panel, its bead and its frame go through the same test as the leaf, so the whole doorset carries the mark together. A doorway where staff need to see through takes the glazed form, while a plant room or a store takes the solid form.
What size opening can a blast door cover?
The survey settles the opening size, and the door is made to those sizes. A single leaf suits a staff door or a store door, and a double leaf suits a plant room or a corridor where trolleys pass. The visit notes clear width, clear height and wall build before the order is placed.
How long does a Sheffield order take from survey to install?
The survey settles the sizes and the rating, the written specification follows, and the fit goes in on dates agreed with the site. The first reply names the fit dates, so the buyer can fit the work around the site programme from the start.
Ready to price a blast door for a Sheffield opening? Get a free quote and send the opening sizes with the rating the site needs.
Other areas
Blast resistant doors in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.