Certified physical security

ArxBridge
Heavy steel-framed glazed curtain wall on a UK government-style office building

Blast · ISO 16933 EXV45 to EXV10

Blast resistant doors in Portsmouth

Blast resistant doors for Portsmouth dockyard, hospital, university and port entrances, rated to ISO 16933 with glazing matched to each leaf.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Portsmouth
Prefer to talk?+44 7352 267239

Get a free quote in Portsmouth

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Portsmouth

What we supply in Portsmouth

More on this

The door at a Portsmouth entrance has one job when a blast load hits it, to stay in its frame and keep the people behind it safe. That job falls on the whole doorset at the Historic Dockyard, where visitors pass HMS Victory, at Queen Alexandra Hospital, where patients and staff move through the day, and at the University of Portsmouth, where students fill the halls and libraries.

A blast resistant door is proved as a doorset, with the blast load applied to leaf, frame, fixings and glazing together. A leaf proved on its own earns no rating, since the frame beside it faces the same load and has to hold it too.

Portsmouth International Port, Gunwharf Quays, Portsmouth Harbour station and the Historic Dockyard each put a different load on their entrances. Freight and passengers move through the port, shoppers fill the quays, crowds pass the station through the day, and visitors gather round the ships and museums, so the class for a door follows the building it guards, and two openings in one building can still need different classes.

Port and dockyardTerminal, port and dockyard entrances
Health and educationQueen Alexandra Hospital and the university
Retail and leisureGunwharf Quays and the harbour station
Doorset ratingThe leaf, frame, fixings and glazing proved together

Where Portsmouth puts a blast rated door to work

The port and the dockyard move people in waves. At Portsmouth International Port, passengers and luggage pass the entrance lanes through the day, and staff watch each lane while the doors work long hours. At the Historic Dockyard, visitors gather round the ships and museums, so the entrance door has to stay in use through the flow and still shut fast at the end of the day.

Queen Alexandra Hospital asks its doors to open fast for staff and stay under control at each entrance, since wards and departments run day and night. The University of Portsmouth asks the same of its halls and libraries, which stay open for students and shut for strangers after hours. The healthcare sector page looks at ward and department doors, and the education sector page looks at doors for colleges and universities.

More crowds gather away from the port. Gunwharf Quays draws shoppers through the day, Portsmouth Harbour station moves travellers between trains and ferries, and the dockyard museums fill on weekends. At those sites the doors sit by the entry lanes and ticket checks, and station entrances are listed in the transport hub security requirements guide, with doors and barriers round a station.

Ratings behind a Portsmouth blast door

The Portsmouth schedule focuses LPS 1175 Issue 8.2 (September 2024) focusing the forced entry grade for each opening beside its blast class. Each grade is fixed by its tool set and its hold time: SR1 is class A1 with a one minute hold, SR2 is class B3 with a three minute hold, SR3 is class C5 with a five minute hold, and SR4 is class D10 with a ten minute hold. Every class in the range sits on the LPS 1175 standard page, while the ratings compared page weighs the three duties against each other for one doorset.

The table pairs five Portsmouth openings with a door build and a class. Each row is a starting point only, since the survey and the blast assessment fix the class that is finally written on the schedule.

Opening in Portsmouth Door build Blast class Forced entry grade
Portsmouth International Port terminal Two leaves, access control EXV SR2, class B3
Historic Dockyard visitor entrance Two leaves, glazed EXV SR2, class B3
Ward door, Queen Alexandra Hospital One leaf, staff only SB SR2, class B3
Hall, University of Portsmouth Two leaves, timed access SB SR2, class B3
Shop front, Gunwharf Quays One leaf, entrance EXV SR3, class C5

Blast classes are proved by a different test from the forced entry grades. For the blast load, ISO 16933 sets the EXV and SB classes, while a glazed assembly that faces a blast takes its EPR and EXR classes from EN 13123 and EN 13124. The class the assembly has to meet is fixed by pressure, duration and debris, and each class is listed in turn on the blast ratings page.

Glass in the leaf needs grading beside the frame. FB1 to FB7 cover the frame with its glazing under EN 1522 and EN 1523. The glass is graded from BR1 to BR7 under EN 1063, and SG1 and SG2 sit beside those grades. Glass, frame and fixings are graded as one set, and the glazed versus solid page weighs a glazed leaf against a solid one. Glazing approval sits with LPS 1270 Issue 1.1 (2014). Classes it covers are listed on the LPS 1270 page.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

What goes into a Portsmouth blast door specification

The specification starts at the opening, with its clear width and height, the build of the wall round it, and the swing the leaf needs. A terminal entrance busy all day and a back-of-house leaf shut through the week need different classes, and remaining choices before pricing are held by the how to specify security doors guide.

Leaf, frame and glazing are settled as one choice. A solid leaf fits an opening that wants no light, while a reception where staff watch the approach fits a glazed leaf, and the frame and its fixings have to match the leaf, since a leaf stronger than its frame earns no rating at all. Those decisions are ordered for a rated doorset on the ten steps to specify page.

Hardware and access control close the specification. Lock, hinges, closer and reader all have to suit the leaf weight and its daily cycles, and a leaf shut overnight needs a lock that holds without power. Crowded places shape the access control too: under Martyn’s Law, expected in spring 2027, a capacity of 800 or more means a place in the enhanced tier, while the standard tier takes capacities of 200 to 799, and what each tier asks of a site is listed on the Martyn’s Law standard page.

Survey and drawings in Portsmouth

Each door position is measured on site before anything is specified. The surveyor notes width, height, wall build and swing for every opening, then power points, access points and the movement of staff and visitors between areas. Sketches and photos of each opening join the record, and the specification is written from that record.

The file for the job is held at our Portsmouth windmill Saffron Road, Romford, Essex RM5 3ES. Pass them to the surveyor with the opening sizes, so the class for each door is written beside its drawing.

Write to [email protected]. We confirm the class for each opening, with the date of the survey, in a written answer sent within one working day.

A final check before the door is ordered

Fix the distance from the street to each entrance before the class is set, since a door that faces the street takes a harder load than one set back behind a forecourt, and the class has to reflect the nearer distance.

Questions buyers in Portsmouth ask about blast doors

Which leaf suits a port terminal entrance, glazed or solid?

A glazed leaf suits a terminal front, since staff there can see who waits outside, while a solid leaf suits a staff entrance or a plant room where no light is wanted.

Does the blast class also prove forced entry?

No. A blast load proves the blast class, and hand tools over a set time prove the forced entry grade, so a door facing both duties needs both classes on its schedule.

What if the leaf is stronger than its frame?

The rating fails with the frame. The whole doorset is proved together, so a leaf that is stronger than its frame still holds no rating on its own. The schedule names frame and fixings beside the leaf, leaving no weak point out.

What care does a blast door need once it is in use?

Care starts with a planned visit. The leaf and frame are checked first, then hinges, lock and closer, and a part showing wear is changed before it fails. The security door maintenance checklist page covers the checks for a door in daily use, and the warranty, defects and guarantees guide names the cover for a part that wears.

Blast resistant doors for a Portsmouth site?

Send the width, height and blast class for each opening, and the leaf, frame and glazing are priced as one doorset. Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.