Certified physical security

ArxBridge
Victorian factory conversion with a navy steel door in Leicester

Blast · ISO 16933 EXV45 to EXV10

Blast Resistant Doors in Leicester

Blast resistant doors for Leicester station, the cathedral quarter, hospitals, the universities and the stadium, specified to ISO 16933 with test evidence.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Leicester
Prefer to talk?+44 7352 267239

Get a free quote in Leicester

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Leicester

What we supply in Leicester

More on this

Any Leicester doorway that opens onto a road used by vehicles is a candidate for a blast resistant door. Crowds move through Leicester station all day, visitors gather at the King Richard III Visitor Centre and Leicester Cathedral, and evening audiences fill the Curve theatre while shoppers fill Highcross, so the doors around those places stand between busy pavements and the rooms behind them.

Leicester Royal Infirmary and the two universities each run a large estate, and the King Power Stadium and the National Space Centre bring match day and school crowds to the edge of the city. Every one of those sites has doors that face a vehicle route, and the threat assessment for each doorway decides its rating. Once the rating is fixed, the door, frame, glazing and hardware are specified as a single tested set. The city-wide picture sits on our physical security in Leicester page.

ArxBridge builds blast resistant doorsets to the measured size of each Leicester opening, with the rating set by the threat at that doorway. Leaf, frame, glazing and hardware are ordered together, so the rating applies to the complete opening rather than to the leaf on its own. An answer arrives inside one working day, carrying a price range and a written specification.

Station and cathedralLeicester station, the cathedral quarter and the visitor centre
Two universitiesEstates of the two universities
Hospital and stadiumLeicester Royal Infirmary and the King Power Stadium
Retail and theatreHighcross shopping centre and the Curve theatre

Doors Leicester asks about first

Council offices and court buildings put their strongest doors on the road side. Staff and visitors use those entrances through the day, delivery vans and lorries pass the same frontage, and the specification therefore pairs a blast class with a forced entry grade on one line. The forced entry, ballistic or blast ratings comparison explains why a blast class alone leaves the forced entry risk unnamed.

At the hospital and the universities, the room behind the door decides the rating. The emergency department at Leicester Royal Infirmary needs a different door from its pharmacy store and its plant room, and a laboratory door, a library entrance and a loading bay door across the two university campuses each face a different risk. Rating doorway by doorway puts the protection where the risk sits and avoids paying for a high class where a lower one would do.

Then there are the crowded sites. Leicester station, the King Power Stadium, the Curve, Highcross and the National Space Centre gather large numbers of people into a small area, and the crowded premises duties Martyn’s Law sets reach all of them. Any door there that faces a vehicle route needs a blast class as part of its physical layer, and the blast doors, glazed and solid guide weighs a glazed leaf next to a solid leaf for those doorways.

A rating for every Leicester opening

The table pairs each Leicester site with the opening that usually drives its rating. Treat it as a starting point: the consultant or the security lead for the site settles the final class from the threat assessment, and pricing follows that decision.

Site in Leicester Doorway Class Doorset
Council offices and courts Staff and public doors on the road side EXV or SB, set by assessment Steel blast resistant doorset
Hospital and university estates Plant rooms, drug stores, loading bays ISO 16933 class, SR2 or SR3 beside it Doorset rated for blast and forced entry
Stadium and station Public entrances by vehicle routes EXV, set by assessment Blast resistant door with panic bars
Highcross shops and hotels Street side front and service doors Class with hazard grade A, B or C Glazed blast resistant door
Space Centre and the Curve Staff yard doors and loading bay doors ISO 16933 class, SR2 beside it Solid steel blast resistant door
Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Writing the specification for a Leicester blast door

Start with the gap from the road to the door, then the threat assessment for that doorway. Those two facts settle the ISO 16933 class, and the guide to specifying security doors lists what else to settle before pricing. The surveyor checks LPS 1175 Issue 8.2 (September 2024) on the forced entry side of that opening, where SR2 names class B3 for a three minute attack, with each class explained on the LPS 1175 standard page. A door that needs both ratings is covered by the ten steps guide for an LPS 1175 door, which works through the forced entry side.

Put leaf, frame, glazing and hardware on one specification line, with the test record for the quoted class beside each part. Add the finish, the threshold and any access control interface, and a fire rating for a door that must also hold back fire, so both duties sit in one document at handover. The specification quotes BS EN 1634-1:2014+A1:2018 at the fire line when the same doorset must also hold back fire, and the classes for glazed units appear on the fire ratings page. Our design team writes the specification for each opening from the threat assessment.

A charge carried by a vehicle is classed on the EXV scale, which turns on charge size and stand off distance. A charge carried by hand is classed on the SB scale. The ISO 16933 EXV versus SB guide shows how the two scales differ, and the blast ratings page lists every class. A glazed leaf needs a hazard grade for its vision panel, running from A, where the pane does not break, to F, where the hazard is high. Hold the frame grade level with the grade of the glazing: a strong leaf fitted in a weak frame still opens a path for the pressure wave. The blast resistant windows cost and specification material covers the glazing side in more depth.

Survey, build and handover in Leicester

A Leicester project opens with a door schedule or drawings that name the class wanted at every opening. On site the surveyor measures each opening, records the wall build, floor level and the services that run through the frame, the escape routes and the way the door is used through the day. Sizes and the fixing method follow from those notes, so every doorset is made for its own measured opening.

Build follows the written specification, and the test records travel with each doorset to site. Fitting and handover fall to the installation service, and after handover the security door maintenance checklist sets the routine checks for the doorset.

Email drawings naming the class at each opening to [email protected], or send the same details via the quote form. A reply arrives inside one working day, bringing a written specification, a class check and a price range.

Frames, leaves and hardware

A class copied from another building rarely fits a Leicester door. Measure the gap from the road to each door, send that figure with the enquiry, and the specification grows from it.

Leicester blast door questions

What sets the ISO 16933 class for a Leicester office door?

The threat assessment for that doorway decides it, weighing the charge size against the gap from the road to the door. A vehicle borne charge takes the EXV scale, a hand carried charge the SB scale.

Can a Leicester door hold two ratings at once?

Yes, if one doorset carries test records for both ratings. Set the ISO 16933 class and the SR class on a single line, with the record for each beside it.

Do Leicester’s stadium and shops need blast resistant doors?

Doors around the stadium, Highcross and the Curve that look onto a vehicle route usually need a blast rating, since the crowded premises duties under Martyn’s Law reach the whole building.

What goes into a Leicester door enquiry?

Send the drawings, the class for every opening and the road to door gap, by email or on the quote form. The answer brings the specification, a class check and a price range, and it arrives inside a working day.

Want a blast resistant door in Leicester?

Send drawings naming the class at each opening, and every one gets a tested doorset named for it. Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.