Certified physical security

ArxBridge
Victorian factory conversion with a navy steel door in Leicester

Fire · EI 30 to EI 120

Fire Rated Steel Doors in Leicester

Fire rated steel doors in Leicester, in E, EW and EI classes from 30 to 120 minutes, for hospitals, universities, offices and retail, with test evidence.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Leicester
Prefer to talk?+44 7352 267239

Get a free quote in Leicester

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Leicester

What we supply in Leicester

More on this

Leicester buyers who order a fire rated steel door are buying minutes. A leaf, frame, seals and ironmongery go into a furnace as one unit, and how long the leaf holds flame, heat and smoke back decides the letters it carries: E, EW or EI, from thirty minutes to two hours. A furnace test that reads BS EN 1634-1:2014+A1:2018 next to those letters is the paper that proves the class, and no brochure figure stands in its place.

Across Leicester the openings that call for this door sit in very different rooms. Lecture blocks, laboratories and student rooms for the University of Leicester and De Montfort University take them, and so do ward doors, corridors and plant rooms at Leicester Royal Infirmary. Shop units and service corridors at Highcross take them next, auditorium doors and back of house routes at the Curve, and concourses and service areas at King Power Stadium. Ticket halls and staff routes at Leicester station take them too, and stair cores and lift lobbies in city centre offices round out the list.

ArxBridge makes these doors for a Leicester opening that has a class written down for it, rather than for a door bought off a shelf. A surveyor measures that opening alone, the doorset is drawn up around its class, its seals and its ironmongery, and the papers for that class are filed beside the order. The wider Leicester picture is set out on our page for physical security in Leicester.

Fire classesE, EW and EI, thirty minutes to two hours
Test basisWhole doorset in the furnace
SealsHeat swelling strips where leaf meets frame
EvidencePapers that name the class ordered

Where Leicester buildings ask for fire rated steel doors

Leicester Royal Infirmary is the clearest case. Wards, corridors and plant rooms there need a door that keeps its class while staff wheel patients and kit through the building, with seals and closers on every door that have to shut true day after day, not just on the day of the test. Our guide on fire door regulations for hospitals looks at hospital fire doors, and the inspection checklist runs through what to check so a door keeps working.

The two universities, the theatre and the stadium show another pattern. Lecture blocks, laboratories and student rooms at the University of Leicester and De Montfort University fill with crowds who need a clear way out, the Curve fills its auditorium through a handful of doors, and King Power Stadium moves crowds through its concourses on match days. A rated steel leaf at a stair core or a service route keeps that way out open. The offices fire door regulations guide covers offices and public buildings, and the guide on fire door regulations for leisure centres looks at buildings that take crowds.

Shops, the station and city centre offices ask one door to do two jobs: open and shut all day, and hold to a fire plan. A Highcross shop unit door swings open again and again and still has to close hard on its closer, a Leicester station door holds smoke back from a staff route, and a lift lobby door keeps smoke clear of the shaft. The fire ratings page sets out each class and the test behind it.

Fire classes and the papers behind them

Each letter in the class names a different job. E is integrity, the leaf keeping flame and hot gas back for the minutes stated. EW puts a cap on heat radiating through the leaf, and EI puts a cap on the temperature of the face on the far side. Half an hour suits a low risk opening; two hours suits a plant room or a stair core where people take longer to get clear. The building fire plan sets the class for each opening, and the written specification records it.

Papers are what turn a class into proof. The furnace runs the whole doorset at once, every part fitted, so swapping any part means new evidence or a written assessment. Where forced entry resistance is needed as well, the rating sets LPS 1175 Issue 8.2 (September 2024) within the specification, and SR2 sits at class B3 under that issue. The SR classes appear one by one on our LPS 1175 standard page. The papers worth asking for are named in the certification guide, before any order is placed.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

What each Leicester building usually needs

Each kind of Leicester building below is paired with the treatment its openings most often take. The building fire plan fixes the final figure, while the survey sets the class for each opening in turn, with the specification signed off before a doorset is ordered.

Leicester building Door position Class to order Other items named
Leicester Royal Infirmary Ward and plant room doors EI 60 to EI 120, per the plan Seals, closer, smoke seals
Universities Student rooms and lecture blocks EI 30 to EI 60, per the plan Closer, vision panel, ironmongery
Highcross and the Curve Shop units, auditorium, service routes EI 60, per the plan Hold open arrangement, seals
King Power Stadium and the station Concourses, ticket halls, staff routes EI 60, per the plan Access control, closer, seals
Offices in the city centre Lift lobbies and stairwells EI 30 to EI 60, per the plan Access control, closer, seals

Setting the specification for a Leicester site

Work from a list of openings. Against every door, write the measured size, the wall build, the class and the ironmongery, and keep the evidence papers that name the quoted class alongside the specification. Ordering a doorset while its papers are still unseen can fail at handover, so look at the evidence first, before the order is placed, not once the door has been delivered. The certification guide names the papers to ask for. The inspection checklist names the checks that follow at handover.

Seals are the centre of the specification. In heat the strips swell and shut the space round the leaf, so the type, the place and the size of each strip are written down for its door, with smoke seals fitted where the fire plan asks for them, and the closer set so the leaf meets its frame hard without a slam. The hinges and the lock go in as tested, and the finish is picked for the room. If access control is needed, the reader place and the power point go on the drawing as well.

From specification to fitting in Leicester

Once the specification is signed off, the workshop builds each doorset to it, and the survey figures go with the build, so a ward door ends up the size the survey recorded. On site, frames go in true and level, leaves are hung with closers set, and every seal is measured against the figure the specification gives for its opening.

The maintenance guide lays out the upkeep each door needs once handed over, so the class on the test papers stays the class the door holds.

Use the quote form for the list of openings, noting the class each opening needs beside it, or put that list in an email to [email protected]. We write back inside a working day, with a price and a specification for every doorset.

Fire door notes for Leicester buyers

Look at the gap round the leaf before the handover record is signed. A door with the right class and a wide gap at the head still lets smoke pass, and a gap is far simpler to put right while the fitters are still there.

Frequently asked questions

Which fire class does a ward door at Leicester Royal Infirmary need?

The building fire plan decides it. Ward, corridor and plant room doors in a hospital often take EI 60 to EI 120. A low risk office opening may take EI 30 instead. Survey and plan together settle each opening’s class.

Can a fire rated steel door in Leicester also carry a security rating?

Yes, when one doorset has been tested for both. The furnace test proves fire resistance, and the LPS 1175 classes prove forced entry resistance. The specification carries both ratings, with the evidence for each one.

When do intumescent seals need replacing on a Leicester door?

Look at the seals at each inspection, and replace any strip that is torn, worn thin or hanging loose from leaf or frame. A worn strip is put right before it fails, so the door holds the class it was tested to.

How is a fire door checked after fitting in Leicester?

Frames are checked for square and level, closers and seals are measured against the figure for each opening, and the handover record lists every opening with its class, seals and ironmongery.

Planning fire rated steel doors for a Leicester building?

Start from the list of openings and the class each one needs, and every doorset gets its specification in return. Request a free quote and the survey starts from there.

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.